{"title":"开发一种在涂油制剂中选择性测定人体皮肤表面维生素 E 的程序","authors":"E. S. Voloshina, B. K. Zuev, A. V. Mikhailova","doi":"10.1134/S1061934824700795","DOIUrl":null,"url":null,"abstract":"<p>A straightforward procedure is developed for the selective determination of alpha-tocopherol acetate (vitamin E) in oil-based cosmetic products, focusing on the evaluation of the sorptive capacity of human skin and the uniformity of the distribution of the preparation on its surface. The procedure is designed to determine vitamin E after application as an oil solution, relying solely on the analyte’s absorption without additional reagents, such as ascorbic acid or an alkali. The procedure involves vitamin E extraction with isopropanol and measuring an analytical signal by UV spectrophotometry. The calibration curve exhibits linearity within the range 0.02–0.1 mg of vitamin E/mL. The limit of detection for vitamin E, calculated from the calibration curve equation and its slope, is 0.5 µg/mL. This procedure has demonstrated reproducibility, selectivity, rapidity, and simplicity.</p>","PeriodicalId":606,"journal":{"name":"Journal of Analytical Chemistry","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Developing a Procedure for the Selective Determination of Vitamin E on Human Skin Surface in Applying Oil Preparations\",\"authors\":\"E. S. Voloshina, B. K. Zuev, A. V. Mikhailova\",\"doi\":\"10.1134/S1061934824700795\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A straightforward procedure is developed for the selective determination of alpha-tocopherol acetate (vitamin E) in oil-based cosmetic products, focusing on the evaluation of the sorptive capacity of human skin and the uniformity of the distribution of the preparation on its surface. The procedure is designed to determine vitamin E after application as an oil solution, relying solely on the analyte’s absorption without additional reagents, such as ascorbic acid or an alkali. The procedure involves vitamin E extraction with isopropanol and measuring an analytical signal by UV spectrophotometry. The calibration curve exhibits linearity within the range 0.02–0.1 mg of vitamin E/mL. The limit of detection for vitamin E, calculated from the calibration curve equation and its slope, is 0.5 µg/mL. This procedure has demonstrated reproducibility, selectivity, rapidity, and simplicity.</p>\",\"PeriodicalId\":606,\"journal\":{\"name\":\"Journal of Analytical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-10-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1061934824700795\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1134/S1061934824700795","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
摘要
针对油基化妆品中α-生育酚醋酸酯(维生素 E)的选择性测定,开发了一种简单易行的程序,重点是评估人体皮肤的吸收能力以及制剂在其表面分布的均匀性。该程序旨在测定维生素 E 作为油溶液使用后的含量,完全依赖于分析物的吸收,无需抗坏血酸或碱等额外试剂。该程序包括用异丙醇提取维生素 E,然后用紫外分光光度法测量分析信号。校准曲线在 0.02-0.1 毫克/毫升维生素 E 的范围内呈线性关系。根据校准曲线方程及其斜率计算,维生素 E 的检测限为 0.5 微克/毫升。该方法具有可重复性、选择性、快速性和简便性。
Developing a Procedure for the Selective Determination of Vitamin E on Human Skin Surface in Applying Oil Preparations
A straightforward procedure is developed for the selective determination of alpha-tocopherol acetate (vitamin E) in oil-based cosmetic products, focusing on the evaluation of the sorptive capacity of human skin and the uniformity of the distribution of the preparation on its surface. The procedure is designed to determine vitamin E after application as an oil solution, relying solely on the analyte’s absorption without additional reagents, such as ascorbic acid or an alkali. The procedure involves vitamin E extraction with isopropanol and measuring an analytical signal by UV spectrophotometry. The calibration curve exhibits linearity within the range 0.02–0.1 mg of vitamin E/mL. The limit of detection for vitamin E, calculated from the calibration curve equation and its slope, is 0.5 µg/mL. This procedure has demonstrated reproducibility, selectivity, rapidity, and simplicity.
期刊介绍:
The Journal of Analytical Chemistry is an international peer reviewed journal that covers theoretical and applied aspects of analytical chemistry; it informs the reader about new achievements in analytical methods, instruments and reagents. Ample space is devoted to problems arising in the analysis of vital media such as water and air. Consideration is given to the detection and determination of metal ions, anions, and various organic substances. The journal welcomes manuscripts from all countries in the English or Russian language.