Tian-You Zhan, Lei Deng, Wen-Qing Wang, Tao Zhang, Jian-Yang Wang, Xin Wang, Wen-Yang Liu, Yi-Rui Zhai, Ze-Fen Xiao, Qin-Fu Feng, Nan Bi, Ye-Xiong Li, Zong-Mei Zhou
{"title":"通过断层治疗和容积调制弧治疗,对局限期小细胞肺癌实施优化的河马回避预防性头颅照射。","authors":"Tian-You Zhan, Lei Deng, Wen-Qing Wang, Tao Zhang, Jian-Yang Wang, Xin Wang, Wen-Yang Liu, Yi-Rui Zhai, Ze-Fen Xiao, Qin-Fu Feng, Nan Bi, Ye-Xiong Li, Zong-Mei Zhou","doi":"10.1111/1759-7714.15462","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Hippo-avoidance prophylactic cranial irradiation (HA-PCI) requires a hippocampal avoidance zone expanded from hippocampus to ensure dose fall-off and compensate for setup errors. Most studies recommend a 5-mm margin, while it could be optimized to a 2-mm expansion. Here, we showed the details of optimized HA-PCI for limited-stage small cell lung cancer (LS-SCLC).</p><p><strong>Methods: </strong>This cohort study reviewed patients with LS-SCLC receiving optimized HA-PCI from August 2014 to June 2020 in the National Cancer Center of China. The hippo-related dose parameters were summarized. The comparison of the Hopkins Verbal Learning Test-Revised (HVLT-R) scores in different time points was conducted. The Kaplan-Meier method was used to calculate the survival rates.</p><p><strong>Results: </strong>A total of 112 patients were included. The average doses of hippocampus and hippocampal avoidance zone were 6.80 Gy (IQR: 6.40-7.44) and 7.63 Gy (IQR: 7.14-8.39). No differences were observed in the two radiation techniques (tomotherapy [TOMO] vs. volumetric-modulated arc therapy [VMAT]). The decline of HVLT-R score remained in a low level and not significant in assessable patients (p = 0.095). With a median follow-up of 52 months (95% CI: 47.2-56.7), the 2-year overall survival and progression-free survival were 74.1% and 50.0%, respectively. Two intracranial recurrence lesions (2.3%) located <2 mm from the hippocampus.</p><p><strong>Conclusions: </strong>Optimized HA-PCI could achieve similar dose limitation by TOMO and VMAT techniques with favorable efficacy and minor toxicity.</p>","PeriodicalId":23338,"journal":{"name":"Thoracic Cancer","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Implementing the optimized hippo-avoidance prophylactic cranial irradiation for limited-stage small cell lung cancer by tomotherapy and volumetric modulated arc therapy.\",\"authors\":\"Tian-You Zhan, Lei Deng, Wen-Qing Wang, Tao Zhang, Jian-Yang Wang, Xin Wang, Wen-Yang Liu, Yi-Rui Zhai, Ze-Fen Xiao, Qin-Fu Feng, Nan Bi, Ye-Xiong Li, Zong-Mei Zhou\",\"doi\":\"10.1111/1759-7714.15462\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Hippo-avoidance prophylactic cranial irradiation (HA-PCI) requires a hippocampal avoidance zone expanded from hippocampus to ensure dose fall-off and compensate for setup errors. Most studies recommend a 5-mm margin, while it could be optimized to a 2-mm expansion. Here, we showed the details of optimized HA-PCI for limited-stage small cell lung cancer (LS-SCLC).</p><p><strong>Methods: </strong>This cohort study reviewed patients with LS-SCLC receiving optimized HA-PCI from August 2014 to June 2020 in the National Cancer Center of China. The hippo-related dose parameters were summarized. The comparison of the Hopkins Verbal Learning Test-Revised (HVLT-R) scores in different time points was conducted. The Kaplan-Meier method was used to calculate the survival rates.</p><p><strong>Results: </strong>A total of 112 patients were included. The average doses of hippocampus and hippocampal avoidance zone were 6.80 Gy (IQR: 6.40-7.44) and 7.63 Gy (IQR: 7.14-8.39). No differences were observed in the two radiation techniques (tomotherapy [TOMO] vs. volumetric-modulated arc therapy [VMAT]). The decline of HVLT-R score remained in a low level and not significant in assessable patients (p = 0.095). With a median follow-up of 52 months (95% CI: 47.2-56.7), the 2-year overall survival and progression-free survival were 74.1% and 50.0%, respectively. Two intracranial recurrence lesions (2.3%) located <2 mm from the hippocampus.</p><p><strong>Conclusions: </strong>Optimized HA-PCI could achieve similar dose limitation by TOMO and VMAT techniques with favorable efficacy and minor toxicity.</p>\",\"PeriodicalId\":23338,\"journal\":{\"name\":\"Thoracic Cancer\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-10-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Thoracic Cancer\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/1759-7714.15462\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thoracic Cancer","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/1759-7714.15462","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
Implementing the optimized hippo-avoidance prophylactic cranial irradiation for limited-stage small cell lung cancer by tomotherapy and volumetric modulated arc therapy.
Background: Hippo-avoidance prophylactic cranial irradiation (HA-PCI) requires a hippocampal avoidance zone expanded from hippocampus to ensure dose fall-off and compensate for setup errors. Most studies recommend a 5-mm margin, while it could be optimized to a 2-mm expansion. Here, we showed the details of optimized HA-PCI for limited-stage small cell lung cancer (LS-SCLC).
Methods: This cohort study reviewed patients with LS-SCLC receiving optimized HA-PCI from August 2014 to June 2020 in the National Cancer Center of China. The hippo-related dose parameters were summarized. The comparison of the Hopkins Verbal Learning Test-Revised (HVLT-R) scores in different time points was conducted. The Kaplan-Meier method was used to calculate the survival rates.
Results: A total of 112 patients were included. The average doses of hippocampus and hippocampal avoidance zone were 6.80 Gy (IQR: 6.40-7.44) and 7.63 Gy (IQR: 7.14-8.39). No differences were observed in the two radiation techniques (tomotherapy [TOMO] vs. volumetric-modulated arc therapy [VMAT]). The decline of HVLT-R score remained in a low level and not significant in assessable patients (p = 0.095). With a median follow-up of 52 months (95% CI: 47.2-56.7), the 2-year overall survival and progression-free survival were 74.1% and 50.0%, respectively. Two intracranial recurrence lesions (2.3%) located <2 mm from the hippocampus.
Conclusions: Optimized HA-PCI could achieve similar dose limitation by TOMO and VMAT techniques with favorable efficacy and minor toxicity.
期刊介绍:
Thoracic Cancer aims to facilitate international collaboration and exchange of comprehensive and cutting-edge information on basic, translational, and applied clinical research in lung cancer, esophageal cancer, mediastinal cancer, breast cancer and other thoracic malignancies. Prevention, treatment and research relevant to Asia-Pacific is a focus area, but submissions from all regions are welcomed. The editors encourage contributions relevant to prevention, general thoracic surgery, medical oncology, radiology, radiation medicine, pathology, basic cancer research, as well as epidemiological and translational studies in thoracic cancer. Thoracic Cancer is the official publication of the Chinese Society of Lung Cancer, International Chinese Society of Thoracic Surgery and is endorsed by the Korean Association for the Study of Lung Cancer and the Hong Kong Cancer Therapy Society.
The Journal publishes a range of article types including: Editorials, Invited Reviews, Mini Reviews, Original Articles, Clinical Guidelines, Technological Notes, Imaging in thoracic cancer, Meeting Reports, Case Reports, Letters to the Editor, Commentaries, and Brief Reports.