超声波膈肌参数在区分猫膈肌功能障碍方面的功效。

IF 1.9 2区 农林科学 Q2 VETERINARY SCIENCES
Phasamon Saisawart, Somchin Sutthigran, Tanya Kasemsuwan, Run Sakulsirajit, Sukullaya Ritthikulprasert, Kittipong Tachampa, Chutimon Thanaboonnipat, Nan Choisunirachon
{"title":"超声波膈肌参数在区分猫膈肌功能障碍方面的功效。","authors":"Phasamon Saisawart, Somchin Sutthigran, Tanya Kasemsuwan, Run Sakulsirajit, Sukullaya Ritthikulprasert, Kittipong Tachampa, Chutimon Thanaboonnipat, Nan Choisunirachon","doi":"10.1177/1098612X241275290","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Diaphragmatic dysfunction (DD) is often underdiagnosed in veterinary medicine. Various ultrasonographic diaphragmatic parameters, including diaphragmatic excursion (DE), diaphragmatic thickness (Tdi) and diaphragmatic thickening fraction (DTF), can be used to identify DD. We aimed to establish normal reference intervals in healthy cats, examine the effects of intrinsic factors on diaphragmatic parameters and evaluate the efficacy of these parameters in identifying DD in healthy and diseased cats.</p><p><strong>Methods: </strong>This prospective observational study was conducted on 22 healthy cats and 12 diseased cats using ultrasonographic techniques to evaluate DE, Tdi and DTF. The correlation between diaphragmatic parameters and intrinsic factors, including sex, age, body weight and body condition score, was analysed using Pearson correlation analysis. Cut-off values for healthy and diseased cats were established using receiver operating characteristic curve analysis.</p><p><strong>Results: </strong>The mean DEs of the left and right hemidiaphragms were 0.66 ± 0.16 and 0.64 ± 0.18 cm, respectively. The mean Tdis in the end-inspiration phase were 0.13 ± 0.03 and 0.12 ± 0.03 cm for the left and right hemidiaphragms, respectively, whereas in the end-expiration phase the mean Tdi was 0.07 ± 0.03 cm for both hemidiaphragms. The DTF ranges for the left and right hemidiaphragms were 23.90-122.1% and 38.80-107%, respectively. Intrinsic factors had no significant impact on DE, Tdi and DTF. The DE measurements for the left hemidiaphragm were more accurate for evaluating diaphragmatic function. To distinguish between healthy and diseased cats, the cut-off value, sensitivity and specificity were 0.458 cm (area under the curve [AUC] 0.846), 75.00% and 86.36%, respectively, for the left hemidiaphragm and 0.423 cm (AUC 0.704), 41.67% and 100%, respectively, for the right hemidiaphragm.</p><p><strong>Conclusions and relevance: </strong>Normal reference values for DE, Tdi and DTF were established for healthy cats. DE, particularly in the left hemidiaphragm, obtained using routine ultrasonography, improves the efficacy of identifying DD and assists clinicians in the diagnosis and treatment of cats with cardiorespiratory disease.</p>","PeriodicalId":15851,"journal":{"name":"Journal of Feline Medicine and Surgery","volume":"26 10","pages":"1098612X241275290"},"PeriodicalIF":1.9000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11523170/pdf/","citationCount":"0","resultStr":"{\"title\":\"Efficacy of ultrasonographic diaphragmatic parameters in distinguishing diaphragmatic dysfunction in cats.\",\"authors\":\"Phasamon Saisawart, Somchin Sutthigran, Tanya Kasemsuwan, Run Sakulsirajit, Sukullaya Ritthikulprasert, Kittipong Tachampa, Chutimon Thanaboonnipat, Nan Choisunirachon\",\"doi\":\"10.1177/1098612X241275290\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Diaphragmatic dysfunction (DD) is often underdiagnosed in veterinary medicine. Various ultrasonographic diaphragmatic parameters, including diaphragmatic excursion (DE), diaphragmatic thickness (Tdi) and diaphragmatic thickening fraction (DTF), can be used to identify DD. We aimed to establish normal reference intervals in healthy cats, examine the effects of intrinsic factors on diaphragmatic parameters and evaluate the efficacy of these parameters in identifying DD in healthy and diseased cats.</p><p><strong>Methods: </strong>This prospective observational study was conducted on 22 healthy cats and 12 diseased cats using ultrasonographic techniques to evaluate DE, Tdi and DTF. The correlation between diaphragmatic parameters and intrinsic factors, including sex, age, body weight and body condition score, was analysed using Pearson correlation analysis. Cut-off values for healthy and diseased cats were established using receiver operating characteristic curve analysis.</p><p><strong>Results: </strong>The mean DEs of the left and right hemidiaphragms were 0.66 ± 0.16 and 0.64 ± 0.18 cm, respectively. The mean Tdis in the end-inspiration phase were 0.13 ± 0.03 and 0.12 ± 0.03 cm for the left and right hemidiaphragms, respectively, whereas in the end-expiration phase the mean Tdi was 0.07 ± 0.03 cm for both hemidiaphragms. The DTF ranges for the left and right hemidiaphragms were 23.90-122.1% and 38.80-107%, respectively. Intrinsic factors had no significant impact on DE, Tdi and DTF. The DE measurements for the left hemidiaphragm were more accurate for evaluating diaphragmatic function. To distinguish between healthy and diseased cats, the cut-off value, sensitivity and specificity were 0.458 cm (area under the curve [AUC] 0.846), 75.00% and 86.36%, respectively, for the left hemidiaphragm and 0.423 cm (AUC 0.704), 41.67% and 100%, respectively, for the right hemidiaphragm.</p><p><strong>Conclusions and relevance: </strong>Normal reference values for DE, Tdi and DTF were established for healthy cats. DE, particularly in the left hemidiaphragm, obtained using routine ultrasonography, improves the efficacy of identifying DD and assists clinicians in the diagnosis and treatment of cats with cardiorespiratory disease.</p>\",\"PeriodicalId\":15851,\"journal\":{\"name\":\"Journal of Feline Medicine and Surgery\",\"volume\":\"26 10\",\"pages\":\"1098612X241275290\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11523170/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Feline Medicine and Surgery\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1177/1098612X241275290\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Feline Medicine and Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1177/1098612X241275290","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

目的:在兽医学中,横膈膜功能障碍(DD)往往诊断不足。各种膈肌超声参数,包括膈肌偏移(DE)、膈肌厚度(Tdi)和膈肌增厚分数(DTF),可用于识别膈肌功能障碍。我们的目的是确定健康猫的正常参考区间,检查内在因素对横膈膜参数的影响,并评估这些参数在鉴别健康和患病猫的 DD 方面的功效:这项前瞻性观察研究针对 22 只健康猫和 12 只患病猫,使用超声波技术评估膈肌、膈肌张力和膈肌张力。使用皮尔逊相关分析法分析了横膈膜参数与内在因素(包括性别、年龄、体重和身体状况评分)之间的相关性。利用接收器操作特征曲线分析法确定了健康猫和患病猫的临界值:左侧和右侧半膈的平均 DE 分别为 0.66 ± 0.16 厘米和 0.64 ± 0.18 厘米。左、右半膈在呼气末期的平均 Tdis 分别为 0.13 ± 0.03 厘米和 0.12 ± 0.03 厘米,而在呼气末期,两个半膈的平均 Tdi 均为 0.07 ± 0.03 厘米。左右半膈的 DTF 范围分别为 23.90-122.1% 和 38.80-107%。内在因素对 DE、Tdi 和 DTF 没有明显影响。左侧半膈的 DE 测量值对评估膈肌功能更为准确。要区分健康猫和患病猫,左侧半膈的临界值、灵敏度和特异性分别为 0.458 厘米(曲线下面积 [AUC] 0.846)、75.00% 和 86.36%;右侧半膈的临界值、灵敏度和特异性分别为 0.423 厘米(曲线下面积 [AUC] 0.704)、41.67% 和 100%:为健康猫建立了正常的 DE、Tdi 和 DTF 参考值。通过常规超声波检查获得的 DE 值,尤其是左侧半膈的 DE 值,可提高 DD 的鉴别效率,帮助临床医生诊断和治疗患有心肺疾病的猫。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Efficacy of ultrasonographic diaphragmatic parameters in distinguishing diaphragmatic dysfunction in cats.

Objectives: Diaphragmatic dysfunction (DD) is often underdiagnosed in veterinary medicine. Various ultrasonographic diaphragmatic parameters, including diaphragmatic excursion (DE), diaphragmatic thickness (Tdi) and diaphragmatic thickening fraction (DTF), can be used to identify DD. We aimed to establish normal reference intervals in healthy cats, examine the effects of intrinsic factors on diaphragmatic parameters and evaluate the efficacy of these parameters in identifying DD in healthy and diseased cats.

Methods: This prospective observational study was conducted on 22 healthy cats and 12 diseased cats using ultrasonographic techniques to evaluate DE, Tdi and DTF. The correlation between diaphragmatic parameters and intrinsic factors, including sex, age, body weight and body condition score, was analysed using Pearson correlation analysis. Cut-off values for healthy and diseased cats were established using receiver operating characteristic curve analysis.

Results: The mean DEs of the left and right hemidiaphragms were 0.66 ± 0.16 and 0.64 ± 0.18 cm, respectively. The mean Tdis in the end-inspiration phase were 0.13 ± 0.03 and 0.12 ± 0.03 cm for the left and right hemidiaphragms, respectively, whereas in the end-expiration phase the mean Tdi was 0.07 ± 0.03 cm for both hemidiaphragms. The DTF ranges for the left and right hemidiaphragms were 23.90-122.1% and 38.80-107%, respectively. Intrinsic factors had no significant impact on DE, Tdi and DTF. The DE measurements for the left hemidiaphragm were more accurate for evaluating diaphragmatic function. To distinguish between healthy and diseased cats, the cut-off value, sensitivity and specificity were 0.458 cm (area under the curve [AUC] 0.846), 75.00% and 86.36%, respectively, for the left hemidiaphragm and 0.423 cm (AUC 0.704), 41.67% and 100%, respectively, for the right hemidiaphragm.

Conclusions and relevance: Normal reference values for DE, Tdi and DTF were established for healthy cats. DE, particularly in the left hemidiaphragm, obtained using routine ultrasonography, improves the efficacy of identifying DD and assists clinicians in the diagnosis and treatment of cats with cardiorespiratory disease.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
17.60%
发文量
254
审稿时长
8-16 weeks
期刊介绍: JFMS is an international, peer-reviewed journal aimed at both practitioners and researchers with an interest in the clinical veterinary healthcare of domestic cats. The journal is published monthly in two formats: ‘Classic’ editions containing high-quality original papers on all aspects of feline medicine and surgery, including basic research relevant to clinical practice; and dedicated ‘Clinical Practice’ editions primarily containing opinionated review articles providing state-of-the-art information for feline clinicians, along with other relevant articles such as consensus guidelines.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信