Seokhwan Bang, Jiwoong Yu, Hoyoung Bae, Dongho Shin, Yong Hyun Park, Hyuk Jin Cho, U-Syn Ha, Ji Youl Lee, Sung-Hoo Hong
{"title":"单孔与多孔机器人腹膜后肾部分切除术:倾向评分匹配比较。","authors":"Seokhwan Bang, Jiwoong Yu, Hoyoung Bae, Dongho Shin, Yong Hyun Park, Hyuk Jin Cho, U-Syn Ha, Ji Youl Lee, Sung-Hoo Hong","doi":"10.1089/end.2024.0493","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Objective:</i></b> To compare the surgical results of retroperitoneal (RP) robot partial nephrectomy (PNx) using either a single-port robot (SP) or a multi-port robot (MP). <b><i>Materials and Methods:</i></b> We retrospectively reviewed all RP robotic PNx performed at a single institution from September 2021-when the SP robot was introduced to the institution-through April 2023. In total, 125 patients underwent the surgery; 81 patients were treated with surgery using a MP robot whereas 44 patients were treated with surgery using a SP. All MP surgeries were performed with da Vinci Xi (Intuitive, Sunnyvale, California, USA), while all SP surgeries were performed with da Vinci SP (Intuitive, Sunnyvale, California, USA). We performed a propensity score-matching (PSM) analysis of these 125 patients. <b><i>Results:</i></b> There was no significant difference between the two groups after PSM. In terms of operation time, that for MP was 103.68 ± 21.89 minutes whereas that for SP was 95.43 ± 32.22 minutes (<i>p</i>-value = 0.164). Meanwhile, in terms of console time, that for MP was 70.95 ± 21.92 minutes whereas that for SP was 64.14 ± 32.06 minutes (<i>p</i>-value = 0.248). In terms of estimated blood loss was 90.91 ± 91.06 mL in MP and 92.27 ± 104.30 mL in SP (<i>p</i>-value = 0.948). Lastly, there was a statistically significant difference in warm ischemic time, as it was 17.18 ± 6.56 minutes in MP and 13.82 ± 4.59 in SP (<i>p</i>-value = 0.007). There were no statistically significant differences between MP and SP in any other surgical outcomes. <b><i>Conclusions:</i></b> SP robot RP PNx demonstrated comparable outcomes to those achieve using MP procedures. This means SP robot RP PNx can be considered a preferable and more convenient surgical approach than conventional methods, particularly when dealing with small renal masses located in the posterior side of the kidney.</p>","PeriodicalId":15723,"journal":{"name":"Journal of endourology","volume":" ","pages":"1353-1358"},"PeriodicalIF":2.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Single-Port Versus Multi-Port Robotic Retroperitoneal Partial Nephrectomy: A Propensity Score-Matched Comparison.\",\"authors\":\"Seokhwan Bang, Jiwoong Yu, Hoyoung Bae, Dongho Shin, Yong Hyun Park, Hyuk Jin Cho, U-Syn Ha, Ji Youl Lee, Sung-Hoo Hong\",\"doi\":\"10.1089/end.2024.0493\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Objective:</i></b> To compare the surgical results of retroperitoneal (RP) robot partial nephrectomy (PNx) using either a single-port robot (SP) or a multi-port robot (MP). <b><i>Materials and Methods:</i></b> We retrospectively reviewed all RP robotic PNx performed at a single institution from September 2021-when the SP robot was introduced to the institution-through April 2023. In total, 125 patients underwent the surgery; 81 patients were treated with surgery using a MP robot whereas 44 patients were treated with surgery using a SP. All MP surgeries were performed with da Vinci Xi (Intuitive, Sunnyvale, California, USA), while all SP surgeries were performed with da Vinci SP (Intuitive, Sunnyvale, California, USA). We performed a propensity score-matching (PSM) analysis of these 125 patients. <b><i>Results:</i></b> There was no significant difference between the two groups after PSM. In terms of operation time, that for MP was 103.68 ± 21.89 minutes whereas that for SP was 95.43 ± 32.22 minutes (<i>p</i>-value = 0.164). Meanwhile, in terms of console time, that for MP was 70.95 ± 21.92 minutes whereas that for SP was 64.14 ± 32.06 minutes (<i>p</i>-value = 0.248). In terms of estimated blood loss was 90.91 ± 91.06 mL in MP and 92.27 ± 104.30 mL in SP (<i>p</i>-value = 0.948). Lastly, there was a statistically significant difference in warm ischemic time, as it was 17.18 ± 6.56 minutes in MP and 13.82 ± 4.59 in SP (<i>p</i>-value = 0.007). There were no statistically significant differences between MP and SP in any other surgical outcomes. <b><i>Conclusions:</i></b> SP robot RP PNx demonstrated comparable outcomes to those achieve using MP procedures. This means SP robot RP PNx can be considered a preferable and more convenient surgical approach than conventional methods, particularly when dealing with small renal masses located in the posterior side of the kidney.</p>\",\"PeriodicalId\":15723,\"journal\":{\"name\":\"Journal of endourology\",\"volume\":\" \",\"pages\":\"1353-1358\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of endourology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1089/end.2024.0493\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"UROLOGY & NEPHROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of endourology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/end.2024.0493","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/24 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
Single-Port Versus Multi-Port Robotic Retroperitoneal Partial Nephrectomy: A Propensity Score-Matched Comparison.
Objective: To compare the surgical results of retroperitoneal (RP) robot partial nephrectomy (PNx) using either a single-port robot (SP) or a multi-port robot (MP). Materials and Methods: We retrospectively reviewed all RP robotic PNx performed at a single institution from September 2021-when the SP robot was introduced to the institution-through April 2023. In total, 125 patients underwent the surgery; 81 patients were treated with surgery using a MP robot whereas 44 patients were treated with surgery using a SP. All MP surgeries were performed with da Vinci Xi (Intuitive, Sunnyvale, California, USA), while all SP surgeries were performed with da Vinci SP (Intuitive, Sunnyvale, California, USA). We performed a propensity score-matching (PSM) analysis of these 125 patients. Results: There was no significant difference between the two groups after PSM. In terms of operation time, that for MP was 103.68 ± 21.89 minutes whereas that for SP was 95.43 ± 32.22 minutes (p-value = 0.164). Meanwhile, in terms of console time, that for MP was 70.95 ± 21.92 minutes whereas that for SP was 64.14 ± 32.06 minutes (p-value = 0.248). In terms of estimated blood loss was 90.91 ± 91.06 mL in MP and 92.27 ± 104.30 mL in SP (p-value = 0.948). Lastly, there was a statistically significant difference in warm ischemic time, as it was 17.18 ± 6.56 minutes in MP and 13.82 ± 4.59 in SP (p-value = 0.007). There were no statistically significant differences between MP and SP in any other surgical outcomes. Conclusions: SP robot RP PNx demonstrated comparable outcomes to those achieve using MP procedures. This means SP robot RP PNx can be considered a preferable and more convenient surgical approach than conventional methods, particularly when dealing with small renal masses located in the posterior side of the kidney.
期刊介绍:
Journal of Endourology, JE Case Reports, and Videourology are the leading peer-reviewed journal, case reports publication, and innovative videojournal companion covering all aspects of minimally invasive urology research, applications, and clinical outcomes.
The leading journal of minimally invasive urology for over 30 years, Journal of Endourology is the essential publication for practicing surgeons who want to keep up with the latest surgical technologies in endoscopic, laparoscopic, robotic, and image-guided procedures as they apply to benign and malignant diseases of the genitourinary tract. This flagship journal includes the companion videojournal Videourology™ with every subscription. While Journal of Endourology remains focused on publishing rigorously peer reviewed articles, Videourology accepts original videos containing material that has not been reported elsewhere, except in the form of an abstract or a conference presentation.
Journal of Endourology coverage includes:
The latest laparoscopic, robotic, endoscopic, and image-guided techniques for treating both benign and malignant conditions
Pioneering research articles
Controversial cases in endourology
Techniques in endourology with accompanying videos
Reviews and epochs in endourology
Endourology survey section of endourology relevant manuscripts published in other journals.