{"title":"与传统超声波相比,剪切波弹性成像提高了慢性肾病的诊断准确性","authors":"Cuiping Jiang, Shiming Zang, Qi Gao, Meili Zhao, Songwang Chen","doi":"10.1002/jcu.23862","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Non-invasive tests are increasingly demanded for diagnosing and prognostication of chronic kidney disease (CKD). Shear-wave elastography (SWE), an emerging technique for measuring tissue stiffness, shows promise for distinguishing between individuals with different stages of renal fibrosis. This study aimed to compare the diagnostic accuracy of two-dimensional SWE (2D-SWE) and conventional ultrasound for detecting CKD, employing renal biopsy as the gold standard.</p><p><strong>Methods: </strong>From May 2020 to October 2023, this prospective study included 30 healthy volunteers and 169 patients with CKD who had undergone 2D-SWE and conventional ultrasound of both kidneys. Cortical and medullary stiffness, cortical pixel intensity, renal length, parenchymal and cortical thickness, interlobar artery peak systolic velocity, end-diastolic velocity (EDV), and resistive index were measured. The diagnostic accuracy of 2D-SWE and conventional ultrasound was compared using the receiver operating characteristic curve (ROC) and Delong test.</p><p><strong>Results: </strong>For diagnosing CKD, the area under the ROC (AUC) of cortical stiffness (0.96 [95% CI, 0.93, 0.99]) was significantly higher than that of all conventional ultrasound parameters, including EDV (0.78 [95% CI, 0.71, 0.86]) and cortical thickness (0.74 [95% CI, 0.67, 0.80]). The sensitivity of cortical stiffness (91%) was significantly higher than that of EDV (68%) and cortical thickness (53%). No significant difference was found in the specificity of cortical stiffness (96%) compared to that of EDV (79%) and cortical thickness (100%).</p><p><strong>Conclusion: </strong>Two-dimensional SWE showed higher diagnostic accuracy than that of conventional ultrasound for detecting CKD.</p>","PeriodicalId":15386,"journal":{"name":"Journal of Clinical Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Shear-Wave Elastography Improves Diagnostic Accuracy in Chronic Kidney Disease Compared to Conventional Ultrasound.\",\"authors\":\"Cuiping Jiang, Shiming Zang, Qi Gao, Meili Zhao, Songwang Chen\",\"doi\":\"10.1002/jcu.23862\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Non-invasive tests are increasingly demanded for diagnosing and prognostication of chronic kidney disease (CKD). Shear-wave elastography (SWE), an emerging technique for measuring tissue stiffness, shows promise for distinguishing between individuals with different stages of renal fibrosis. This study aimed to compare the diagnostic accuracy of two-dimensional SWE (2D-SWE) and conventional ultrasound for detecting CKD, employing renal biopsy as the gold standard.</p><p><strong>Methods: </strong>From May 2020 to October 2023, this prospective study included 30 healthy volunteers and 169 patients with CKD who had undergone 2D-SWE and conventional ultrasound of both kidneys. Cortical and medullary stiffness, cortical pixel intensity, renal length, parenchymal and cortical thickness, interlobar artery peak systolic velocity, end-diastolic velocity (EDV), and resistive index were measured. The diagnostic accuracy of 2D-SWE and conventional ultrasound was compared using the receiver operating characteristic curve (ROC) and Delong test.</p><p><strong>Results: </strong>For diagnosing CKD, the area under the ROC (AUC) of cortical stiffness (0.96 [95% CI, 0.93, 0.99]) was significantly higher than that of all conventional ultrasound parameters, including EDV (0.78 [95% CI, 0.71, 0.86]) and cortical thickness (0.74 [95% CI, 0.67, 0.80]). The sensitivity of cortical stiffness (91%) was significantly higher than that of EDV (68%) and cortical thickness (53%). No significant difference was found in the specificity of cortical stiffness (96%) compared to that of EDV (79%) and cortical thickness (100%).</p><p><strong>Conclusion: </strong>Two-dimensional SWE showed higher diagnostic accuracy than that of conventional ultrasound for detecting CKD.</p>\",\"PeriodicalId\":15386,\"journal\":{\"name\":\"Journal of Clinical Ultrasound\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-10-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Ultrasound\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/jcu.23862\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/jcu.23862","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
Shear-Wave Elastography Improves Diagnostic Accuracy in Chronic Kidney Disease Compared to Conventional Ultrasound.
Purpose: Non-invasive tests are increasingly demanded for diagnosing and prognostication of chronic kidney disease (CKD). Shear-wave elastography (SWE), an emerging technique for measuring tissue stiffness, shows promise for distinguishing between individuals with different stages of renal fibrosis. This study aimed to compare the diagnostic accuracy of two-dimensional SWE (2D-SWE) and conventional ultrasound for detecting CKD, employing renal biopsy as the gold standard.
Methods: From May 2020 to October 2023, this prospective study included 30 healthy volunteers and 169 patients with CKD who had undergone 2D-SWE and conventional ultrasound of both kidneys. Cortical and medullary stiffness, cortical pixel intensity, renal length, parenchymal and cortical thickness, interlobar artery peak systolic velocity, end-diastolic velocity (EDV), and resistive index were measured. The diagnostic accuracy of 2D-SWE and conventional ultrasound was compared using the receiver operating characteristic curve (ROC) and Delong test.
Results: For diagnosing CKD, the area under the ROC (AUC) of cortical stiffness (0.96 [95% CI, 0.93, 0.99]) was significantly higher than that of all conventional ultrasound parameters, including EDV (0.78 [95% CI, 0.71, 0.86]) and cortical thickness (0.74 [95% CI, 0.67, 0.80]). The sensitivity of cortical stiffness (91%) was significantly higher than that of EDV (68%) and cortical thickness (53%). No significant difference was found in the specificity of cortical stiffness (96%) compared to that of EDV (79%) and cortical thickness (100%).
Conclusion: Two-dimensional SWE showed higher diagnostic accuracy than that of conventional ultrasound for detecting CKD.
期刊介绍:
The Journal of Clinical Ultrasound (JCU) is an international journal dedicated to the worldwide dissemination of scientific information on diagnostic and therapeutic applications of medical sonography.
The scope of the journal includes--but is not limited to--the following areas: sonography of the gastrointestinal tract, genitourinary tract, vascular system, nervous system, head and neck, chest, breast, musculoskeletal system, and other superficial structures; Doppler applications; obstetric and pediatric applications; and interventional sonography. Studies comparing sonography with other imaging modalities are encouraged, as are studies evaluating the economic impact of sonography. Also within the journal''s scope are innovations and improvements in instrumentation and examination techniques and the use of contrast agents.
JCU publishes original research articles, case reports, pictorial essays, technical notes, and letters to the editor. The journal is also dedicated to being an educational resource for its readers, through the publication of review articles and various scientific contributions from members of the editorial board and other world-renowned experts in sonography.