佩戴不同直径的巩膜透镜时小梁虹膜角和前房的短期变化。

IF 1.5 4区 医学 Q3 OPHTHALMOLOGY
Clinical and Experimental Optometry Pub Date : 2025-09-01 Epub Date: 2024-10-27 DOI:10.1080/08164622.2024.2418822
Juan Queiruga-Piñeiro, Javier Lozano-Sanroma, Alberto Barros, Ignacio Rodríguez-Uña, Luis Fernández-Vega Cueto-Felgueroso, Jesús Merayo-Lloves
{"title":"佩戴不同直径的巩膜透镜时小梁虹膜角和前房的短期变化。","authors":"Juan Queiruga-Piñeiro, Javier Lozano-Sanroma, Alberto Barros, Ignacio Rodríguez-Uña, Luis Fernández-Vega Cueto-Felgueroso, Jesús Merayo-Lloves","doi":"10.1080/08164622.2024.2418822","DOIUrl":null,"url":null,"abstract":"<p><strong>Clinical relevance: </strong>Scleral lens (SL) compression on the conjunctiva/episclera during wear may alter adjacent structures related to aqueous humour drainage.</p><p><strong>Background: </strong>The aim of this work was to assess short-term changes in the four quadrants of trabecular iris angle (TIA) and anterior chamber parameters during SL wear, using anterior segment optical coherence tomography (AS-OCT).</p><p><strong>Methods: </strong>Prospective study was conducted involving 16 healthy subjects with a mean age of 28 ± 5 years. Two SL of diameter 15.80 mm (L1) and 16.80 mm (L2) with the same parameters were used for 2 hours in different days. The central fluid reservoir (FR), the TIA in superior, inferior, nasal, temporal quadrants, and anterior chamber parameters; anterior chamber depth (ACD), anterior chamber width (ACW), anterior chamber area (ACAr) and anterior chamber volume (ACV) were measured with AS-OCT. These measurements were performed immediately after SL application (0 h), one hour (1 h) and two hours (2 h) of SL wear.</p><p><strong>Results: </strong>TIA decreases significantly in the superior quadrant at 2 hours of L2 wear (-5.19 ± 7.79º) (<i>p</i> = 0.04). In this sector, differences were also observed between the changes induced by both lenses during the 2 hours of wear (<i>p</i> = 0.04) and between first and second hours of wear (<i>p</i> = 0.04). ACD was significantly lower with L1 (-0.09 ± 0.14 mm) relative to L2 (0.00 ± 0.06 mm) between immediately after the application and 2 hours of wear (<i>p</i> = 0.02). A significant reduction in ACAr at 1 hour (-0.65 ± 0.75 mm<sup>2</sup>) (<i>p</i> = 0.01) and 2 hours of wear (-0.81 ± 1.15 mm<sup>2</sup>) (<i>p</i> = 0.04), as well as in ACW at 2 hours (-0.11 ± 0.14 mm) (<i>p</i> = 0.02) compared to immediately after application of L1 was found.</p><p><strong>Conclusion: </strong>Small changes in TIA and anterior chamber occur during two hours of SL wear, but these changes are of limited clinical relevance in healthy subjects.</p>","PeriodicalId":10214,"journal":{"name":"Clinical and Experimental Optometry","volume":" ","pages":"800-806"},"PeriodicalIF":1.5000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Short-term changes in the trabecular iris angle and anterior chamber during wear of scleral lenses with different diameters.\",\"authors\":\"Juan Queiruga-Piñeiro, Javier Lozano-Sanroma, Alberto Barros, Ignacio Rodríguez-Uña, Luis Fernández-Vega Cueto-Felgueroso, Jesús Merayo-Lloves\",\"doi\":\"10.1080/08164622.2024.2418822\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Clinical relevance: </strong>Scleral lens (SL) compression on the conjunctiva/episclera during wear may alter adjacent structures related to aqueous humour drainage.</p><p><strong>Background: </strong>The aim of this work was to assess short-term changes in the four quadrants of trabecular iris angle (TIA) and anterior chamber parameters during SL wear, using anterior segment optical coherence tomography (AS-OCT).</p><p><strong>Methods: </strong>Prospective study was conducted involving 16 healthy subjects with a mean age of 28 ± 5 years. Two SL of diameter 15.80 mm (L1) and 16.80 mm (L2) with the same parameters were used for 2 hours in different days. The central fluid reservoir (FR), the TIA in superior, inferior, nasal, temporal quadrants, and anterior chamber parameters; anterior chamber depth (ACD), anterior chamber width (ACW), anterior chamber area (ACAr) and anterior chamber volume (ACV) were measured with AS-OCT. These measurements were performed immediately after SL application (0 h), one hour (1 h) and two hours (2 h) of SL wear.</p><p><strong>Results: </strong>TIA decreases significantly in the superior quadrant at 2 hours of L2 wear (-5.19 ± 7.79º) (<i>p</i> = 0.04). In this sector, differences were also observed between the changes induced by both lenses during the 2 hours of wear (<i>p</i> = 0.04) and between first and second hours of wear (<i>p</i> = 0.04). ACD was significantly lower with L1 (-0.09 ± 0.14 mm) relative to L2 (0.00 ± 0.06 mm) between immediately after the application and 2 hours of wear (<i>p</i> = 0.02). A significant reduction in ACAr at 1 hour (-0.65 ± 0.75 mm<sup>2</sup>) (<i>p</i> = 0.01) and 2 hours of wear (-0.81 ± 1.15 mm<sup>2</sup>) (<i>p</i> = 0.04), as well as in ACW at 2 hours (-0.11 ± 0.14 mm) (<i>p</i> = 0.02) compared to immediately after application of L1 was found.</p><p><strong>Conclusion: </strong>Small changes in TIA and anterior chamber occur during two hours of SL wear, but these changes are of limited clinical relevance in healthy subjects.</p>\",\"PeriodicalId\":10214,\"journal\":{\"name\":\"Clinical and Experimental Optometry\",\"volume\":\" \",\"pages\":\"800-806\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2025-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical and Experimental Optometry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/08164622.2024.2418822\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Optometry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/08164622.2024.2418822","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

临床意义:巩膜透镜(SL)在佩戴过程中对结膜/巩膜的压迫可能会改变与水液引流相关的邻近结构:本研究的目的是使用前节光学相干断层扫描(AS-OCT)评估佩戴巩膜透镜期间小梁虹膜角(TIA)的四个象限和前房参数的短期变化:这项前瞻性研究涉及 16 名健康受试者,平均年龄为 28±5 岁。受试者在不同的日子里使用了两个直径分别为 15.80 毫米(L1)和 16.80 毫米(L2)、参数相同的角膜塑形镜 2 小时。使用 AS-OCT 测量了中央储液器 (FR)、上象限、下象限、鼻象限、颞象限的 TIA 和前房参数;前房深度 (ACD)、前房宽度 (ACW)、前房面积 (ACAr) 和前房容积 (ACV)。这些测量分别在佩戴 SL 后立即进行(0 小时)、佩戴 SL 1 小时后进行(1 小时)和佩戴 SL 2 小时后进行(2 小时):结果:佩戴 L2 2 小时后,上象限的 TIA 明显下降(-5.19 ± 7.79º)(p = 0.04)。在这一区域,两种镜片在佩戴 2 小时内(p = 0.04)以及佩戴第一和第二小时之间(p = 0.04)引起的变化也存在差异。在刚佩戴后和佩戴 2 小时之间,L1 的 ACD(-0.09 ± 0.14 毫米)明显低于 L2(0.00 ± 0.06 毫米)(p = 0.02)。与刚佩戴 L1 时相比,佩戴 1 小时(-0.65 ± 0.75 mm2)(p = 0.01)和 2 小时(-0.81 ± 1.15 mm2)(p = 0.04)时的 ACAr 以及佩戴 2 小时时的 ACW(-0.11 ± 0.14 mm)(p = 0.02)均明显减少:结论:SL 佩戴两小时后,TIA 和前房发生微小变化,但这些变化对健康受试者的临床意义有限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Short-term changes in the trabecular iris angle and anterior chamber during wear of scleral lenses with different diameters.

Clinical relevance: Scleral lens (SL) compression on the conjunctiva/episclera during wear may alter adjacent structures related to aqueous humour drainage.

Background: The aim of this work was to assess short-term changes in the four quadrants of trabecular iris angle (TIA) and anterior chamber parameters during SL wear, using anterior segment optical coherence tomography (AS-OCT).

Methods: Prospective study was conducted involving 16 healthy subjects with a mean age of 28 ± 5 years. Two SL of diameter 15.80 mm (L1) and 16.80 mm (L2) with the same parameters were used for 2 hours in different days. The central fluid reservoir (FR), the TIA in superior, inferior, nasal, temporal quadrants, and anterior chamber parameters; anterior chamber depth (ACD), anterior chamber width (ACW), anterior chamber area (ACAr) and anterior chamber volume (ACV) were measured with AS-OCT. These measurements were performed immediately after SL application (0 h), one hour (1 h) and two hours (2 h) of SL wear.

Results: TIA decreases significantly in the superior quadrant at 2 hours of L2 wear (-5.19 ± 7.79º) (p = 0.04). In this sector, differences were also observed between the changes induced by both lenses during the 2 hours of wear (p = 0.04) and between first and second hours of wear (p = 0.04). ACD was significantly lower with L1 (-0.09 ± 0.14 mm) relative to L2 (0.00 ± 0.06 mm) between immediately after the application and 2 hours of wear (p = 0.02). A significant reduction in ACAr at 1 hour (-0.65 ± 0.75 mm2) (p = 0.01) and 2 hours of wear (-0.81 ± 1.15 mm2) (p = 0.04), as well as in ACW at 2 hours (-0.11 ± 0.14 mm) (p = 0.02) compared to immediately after application of L1 was found.

Conclusion: Small changes in TIA and anterior chamber occur during two hours of SL wear, but these changes are of limited clinical relevance in healthy subjects.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
5.30%
发文量
132
审稿时长
6-12 weeks
期刊介绍: Clinical and Experimental Optometry is a peer reviewed journal listed by ISI and abstracted by PubMed, Web of Science, Scopus, Science Citation Index and Current Contents. It publishes original research papers and reviews in clinical optometry and vision science. Debate and discussion of controversial scientific and clinical issues is encouraged and letters to the Editor and short communications expressing points of view on matters within the Journal''s areas of interest are welcome. The Journal is published six times annually.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信