腓骨游离瓣下颌骨体重建中羟基磷灰石/聚乳酸固定的生物力学评估:结合材料特性和咀嚼功能评估的有限元分析。

IF 3.8 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Sang-Min Lee, Tae-Gon Jung, Won-Hyeon Kim, Bongju Kim, Jee-Ho Lee
{"title":"腓骨游离瓣下颌骨体重建中羟基磷灰石/聚乳酸固定的生物力学评估:结合材料特性和咀嚼功能评估的有限元分析。","authors":"Sang-Min Lee, Tae-Gon Jung, Won-Hyeon Kim, Bongju Kim, Jee-Ho Lee","doi":"10.3390/bioengineering11101009","DOIUrl":null,"url":null,"abstract":"<p><p>In reconstructive surgery following partial mandibulectomy, the biomechanical integrity of the fibula free flap applied to the remaining mandibular region directly influences the prognosis of the surgery. The purpose of this study is to evaluate the biomechanical integrity of two fixation materials [titanium (Ti) and hydroxyapatite/poly-L-lactide (HA-PLLA)]. In this study, we simulated the mechanical properties of miniplate and screw fixations in two different systems by finite element analysis. A three-dimensional mandibular model was constructed and a fibula free flap and reconstruction surface were designed. The anterior and posterior end of the free flap was positioned with two miniplates and two additional miniplates were applied to the angled area of the fibula. The masticatory loading was applied considering seven principal muscles. The peak von Mises stress (PVMS) distribution, size of fixation deformation, principal stresses on bones, and gap opening size were measured to evaluate the material properties of the fixation. In the evaluation of properties, superior results were observed with both fixation methods immediately after surgery. However, after the formation of callus between bone segments at 2 months, the performance of Ti fixation decreased over time and the differences between the two fixations became minimal by 6 months after surgery. The result of the study implies the positive clinical potential of the HA-PLLA fixation system applied in fibula free flap reconstruction.</p>","PeriodicalId":8874,"journal":{"name":"Bioengineering","volume":"11 10","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2024-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11505077/pdf/","citationCount":"0","resultStr":"{\"title\":\"Biomechanical Evaluation of Hydroxyapatite/poly-l-lactide Fixation in Mandibular Body Reconstruction with Fibula Free Flap: A Finite Element Analysis Incorporating Material Properties and Masticatory Function Evaluation.\",\"authors\":\"Sang-Min Lee, Tae-Gon Jung, Won-Hyeon Kim, Bongju Kim, Jee-Ho Lee\",\"doi\":\"10.3390/bioengineering11101009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In reconstructive surgery following partial mandibulectomy, the biomechanical integrity of the fibula free flap applied to the remaining mandibular region directly influences the prognosis of the surgery. The purpose of this study is to evaluate the biomechanical integrity of two fixation materials [titanium (Ti) and hydroxyapatite/poly-L-lactide (HA-PLLA)]. In this study, we simulated the mechanical properties of miniplate and screw fixations in two different systems by finite element analysis. A three-dimensional mandibular model was constructed and a fibula free flap and reconstruction surface were designed. The anterior and posterior end of the free flap was positioned with two miniplates and two additional miniplates were applied to the angled area of the fibula. The masticatory loading was applied considering seven principal muscles. The peak von Mises stress (PVMS) distribution, size of fixation deformation, principal stresses on bones, and gap opening size were measured to evaluate the material properties of the fixation. In the evaluation of properties, superior results were observed with both fixation methods immediately after surgery. However, after the formation of callus between bone segments at 2 months, the performance of Ti fixation decreased over time and the differences between the two fixations became minimal by 6 months after surgery. The result of the study implies the positive clinical potential of the HA-PLLA fixation system applied in fibula free flap reconstruction.</p>\",\"PeriodicalId\":8874,\"journal\":{\"name\":\"Bioengineering\",\"volume\":\"11 10\",\"pages\":\"\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11505077/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioengineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3390/bioengineering11101009\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioengineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/bioengineering11101009","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

在下颌骨部分切除术后的重建手术中,应用于剩余下颌骨区域的腓骨游离瓣的生物力学完整性直接影响着手术的预后。本研究旨在评估两种固定材料(钛(Ti)和羟基磷灰石/聚左旋乳酸(HA-PLLA))的生物力学完整性。在这项研究中,我们通过有限元分析模拟了两种不同系统中微型板和螺钉固定的机械性能。我们构建了一个三维下颌骨模型,并设计了腓骨游离瓣和重建面。游离瓣的前端和后端使用两个小钢板定位,另外两个小钢板应用于腓骨的成角区域。咀嚼加载考虑了七块主要肌肉。测量了峰值冯-米塞斯应力(PVMS)分布、固定变形大小、骨骼上的主要应力和间隙开口大小,以评估固定装置的材料特性。在性能评估中,两种固定方法在术后都能立即观察到较好的效果。然而,在术后 2 个月骨段之间形成胼胝后,钛固定的性能随着时间的推移而下降,到术后 6 个月时,两种固定方法之间的差异变得微乎其微。研究结果表明,HA-PLLA 固定系统在腓骨游离皮瓣重建中的应用具有积极的临床潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Biomechanical Evaluation of Hydroxyapatite/poly-l-lactide Fixation in Mandibular Body Reconstruction with Fibula Free Flap: A Finite Element Analysis Incorporating Material Properties and Masticatory Function Evaluation.

In reconstructive surgery following partial mandibulectomy, the biomechanical integrity of the fibula free flap applied to the remaining mandibular region directly influences the prognosis of the surgery. The purpose of this study is to evaluate the biomechanical integrity of two fixation materials [titanium (Ti) and hydroxyapatite/poly-L-lactide (HA-PLLA)]. In this study, we simulated the mechanical properties of miniplate and screw fixations in two different systems by finite element analysis. A three-dimensional mandibular model was constructed and a fibula free flap and reconstruction surface were designed. The anterior and posterior end of the free flap was positioned with two miniplates and two additional miniplates were applied to the angled area of the fibula. The masticatory loading was applied considering seven principal muscles. The peak von Mises stress (PVMS) distribution, size of fixation deformation, principal stresses on bones, and gap opening size were measured to evaluate the material properties of the fixation. In the evaluation of properties, superior results were observed with both fixation methods immediately after surgery. However, after the formation of callus between bone segments at 2 months, the performance of Ti fixation decreased over time and the differences between the two fixations became minimal by 6 months after surgery. The result of the study implies the positive clinical potential of the HA-PLLA fixation system applied in fibula free flap reconstruction.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bioengineering
Bioengineering Chemical Engineering-Bioengineering
CiteScore
4.00
自引率
8.70%
发文量
661
期刊介绍: Aims Bioengineering (ISSN 2306-5354) provides an advanced forum for the science and technology of bioengineering. It publishes original research papers, comprehensive reviews, communications and case reports. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. All aspects of bioengineering are welcomed from theoretical concepts to education and applications. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. There are, in addition, four key features of this Journal: ● We are introducing a new concept in scientific and technical publications “The Translational Case Report in Bioengineering”. It is a descriptive explanatory analysis of a transformative or translational event. Understanding that the goal of bioengineering scholarship is to advance towards a transformative or clinical solution to an identified transformative/clinical need, the translational case report is used to explore causation in order to find underlying principles that may guide other similar transformative/translational undertakings. ● Manuscripts regarding research proposals and research ideas will be particularly welcomed. ● Electronic files and software regarding the full details of the calculation and experimental procedure, if unable to be published in a normal way, can be deposited as supplementary material. ● We also accept manuscripts communicating to a broader audience with regard to research projects financed with public funds. Scope ● Bionics and biological cybernetics: implantology; bio–abio interfaces ● Bioelectronics: wearable electronics; implantable electronics; “more than Moore” electronics; bioelectronics devices ● Bioprocess and biosystems engineering and applications: bioprocess design; biocatalysis; bioseparation and bioreactors; bioinformatics; bioenergy; etc. ● Biomolecular, cellular and tissue engineering and applications: tissue engineering; chromosome engineering; embryo engineering; cellular, molecular and synthetic biology; metabolic engineering; bio-nanotechnology; micro/nano technologies; genetic engineering; transgenic technology ● Biomedical engineering and applications: biomechatronics; biomedical electronics; biomechanics; biomaterials; biomimetics; biomedical diagnostics; biomedical therapy; biomedical devices; sensors and circuits; biomedical imaging and medical information systems; implants and regenerative medicine; neurotechnology; clinical engineering; rehabilitation engineering ● Biochemical engineering and applications: metabolic pathway engineering; modeling and simulation ● Translational bioengineering
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信