Chiara Mazziotta, Giada Badiale, Christian Felice Cervellera, Giulia Tonnini, Milena Oimo, Antoine Touzé, Françoise Arnold, Stefania Zanussi, Ornella Schioppa, Giuseppe Fanetti, Mauro Tognon, Fernanda Martini, John Charles Rotondo
{"title":"用新型免疫测定法检测健康人和梅克尔细胞癌患者血清中针对梅克尔细胞多瘤病毒肿瘤蛋白拟态的抗体。","authors":"Chiara Mazziotta, Giada Badiale, Christian Felice Cervellera, Giulia Tonnini, Milena Oimo, Antoine Touzé, Françoise Arnold, Stefania Zanussi, Ornella Schioppa, Giuseppe Fanetti, Mauro Tognon, Fernanda Martini, John Charles Rotondo","doi":"10.1111/1751-7915.14536","DOIUrl":null,"url":null,"abstract":"<p>Merkel cell polyomavirus (MCPyV) is the foremost causative factor of Merkel cell carcinoma (MCC), a rare yet highly aggressive skin cancer. Although the evaluation of circulating IgG antibodies against Merkel cell polyomavirus (MCPyV) LT/sT oncoproteins is clinically useful for MCC diagnosis/prognosis, a limited number of assays for identifying such antibodies have been developed. Herein, a novel indirect immunoassay with synthetic epitopes/mimotopes of MCPyV oncoproteins was computationally designed and experimentally validated on control sera and sera from healthy individuals and MCC patients. Upon computational design of five synthetic peptides, the performance of the immunoassay in detecting anti-oncoprotein IgGs in MCPyV-positive and -negative control sera was evaluated. The immunoassay was afterwards extended on sera from healthy individuals, and, for longitudinal analysis, MCC patients. Performance properties such as sensitivity and specificity and positive/negative predictive values were adequate. Receiver-operating characteristic (ROC) curves indicated that the areas under the curves (AUCs) were within the low/moderately accurate ranges. Immunoassay was repeatable, reproducible and accurate. As expected, the serum anti-oncoprotein IgG prevalence in healthy individuals was low (2%–5%). Anti-oncoprotein IgGs slightly increased when MCC patients experienced partial tumour remission and/or stable disease, compared to baseline. Our data indicate that the newly developed immunoassay is reliable for detecting circulating anti-oncoprotein IgGs both in healthy individuals and MCC patients.</p>","PeriodicalId":209,"journal":{"name":"Microbial Biotechnology","volume":"17 10","pages":""},"PeriodicalIF":5.7000,"publicationDate":"2024-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11511775/pdf/","citationCount":"0","resultStr":"{\"title\":\"Serum antibodies against mimotopes of Merkel cell polyomavirus oncoproteins detected by a novel immunoassay in healthy individuals and Merkel cell carcinoma patients\",\"authors\":\"Chiara Mazziotta, Giada Badiale, Christian Felice Cervellera, Giulia Tonnini, Milena Oimo, Antoine Touzé, Françoise Arnold, Stefania Zanussi, Ornella Schioppa, Giuseppe Fanetti, Mauro Tognon, Fernanda Martini, John Charles Rotondo\",\"doi\":\"10.1111/1751-7915.14536\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Merkel cell polyomavirus (MCPyV) is the foremost causative factor of Merkel cell carcinoma (MCC), a rare yet highly aggressive skin cancer. Although the evaluation of circulating IgG antibodies against Merkel cell polyomavirus (MCPyV) LT/sT oncoproteins is clinically useful for MCC diagnosis/prognosis, a limited number of assays for identifying such antibodies have been developed. Herein, a novel indirect immunoassay with synthetic epitopes/mimotopes of MCPyV oncoproteins was computationally designed and experimentally validated on control sera and sera from healthy individuals and MCC patients. Upon computational design of five synthetic peptides, the performance of the immunoassay in detecting anti-oncoprotein IgGs in MCPyV-positive and -negative control sera was evaluated. The immunoassay was afterwards extended on sera from healthy individuals, and, for longitudinal analysis, MCC patients. Performance properties such as sensitivity and specificity and positive/negative predictive values were adequate. Receiver-operating characteristic (ROC) curves indicated that the areas under the curves (AUCs) were within the low/moderately accurate ranges. Immunoassay was repeatable, reproducible and accurate. As expected, the serum anti-oncoprotein IgG prevalence in healthy individuals was low (2%–5%). Anti-oncoprotein IgGs slightly increased when MCC patients experienced partial tumour remission and/or stable disease, compared to baseline. Our data indicate that the newly developed immunoassay is reliable for detecting circulating anti-oncoprotein IgGs both in healthy individuals and MCC patients.</p>\",\"PeriodicalId\":209,\"journal\":{\"name\":\"Microbial Biotechnology\",\"volume\":\"17 10\",\"pages\":\"\"},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11511775/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microbial Biotechnology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/1751-7915.14536\",\"RegionNum\":2,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microbial Biotechnology","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/1751-7915.14536","RegionNum":2,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Serum antibodies against mimotopes of Merkel cell polyomavirus oncoproteins detected by a novel immunoassay in healthy individuals and Merkel cell carcinoma patients
Merkel cell polyomavirus (MCPyV) is the foremost causative factor of Merkel cell carcinoma (MCC), a rare yet highly aggressive skin cancer. Although the evaluation of circulating IgG antibodies against Merkel cell polyomavirus (MCPyV) LT/sT oncoproteins is clinically useful for MCC diagnosis/prognosis, a limited number of assays for identifying such antibodies have been developed. Herein, a novel indirect immunoassay with synthetic epitopes/mimotopes of MCPyV oncoproteins was computationally designed and experimentally validated on control sera and sera from healthy individuals and MCC patients. Upon computational design of five synthetic peptides, the performance of the immunoassay in detecting anti-oncoprotein IgGs in MCPyV-positive and -negative control sera was evaluated. The immunoassay was afterwards extended on sera from healthy individuals, and, for longitudinal analysis, MCC patients. Performance properties such as sensitivity and specificity and positive/negative predictive values were adequate. Receiver-operating characteristic (ROC) curves indicated that the areas under the curves (AUCs) were within the low/moderately accurate ranges. Immunoassay was repeatable, reproducible and accurate. As expected, the serum anti-oncoprotein IgG prevalence in healthy individuals was low (2%–5%). Anti-oncoprotein IgGs slightly increased when MCC patients experienced partial tumour remission and/or stable disease, compared to baseline. Our data indicate that the newly developed immunoassay is reliable for detecting circulating anti-oncoprotein IgGs both in healthy individuals and MCC patients.
期刊介绍:
Microbial Biotechnology publishes papers of original research reporting significant advances in any aspect of microbial applications, including, but not limited to biotechnologies related to: Green chemistry; Primary metabolites; Food, beverages and supplements; Secondary metabolites and natural products; Pharmaceuticals; Diagnostics; Agriculture; Bioenergy; Biomining, including oil recovery and processing; Bioremediation; Biopolymers, biomaterials; Bionanotechnology; Biosurfactants and bioemulsifiers; Compatible solutes and bioprotectants; Biosensors, monitoring systems, quantitative microbial risk assessment; Technology development; Protein engineering; Functional genomics; Metabolic engineering; Metabolic design; Systems analysis, modelling; Process engineering; Biologically-based analytical methods; Microbially-based strategies in public health; Microbially-based strategies to influence global processes