血液透析患者扫描次数越多,准确性越高:观察性研究发现 28 区方案更胜一筹。

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Christodoulos Keskinis, Stylianos Panagoutsos, Parthena Kyriklidou, Panagiotis Pateinakis, Eleni Manou, Eleni Soilemezi, Dorothea Papadopoulou, Ploumis Passadakis
{"title":"血液透析患者扫描次数越多,准确性越高:观察性研究发现 28 区方案更胜一筹。","authors":"Christodoulos Keskinis, Stylianos Panagoutsos, Parthena Kyriklidou, Panagiotis Pateinakis, Eleni Manou, Eleni Soilemezi, Dorothea Papadopoulou, Ploumis Passadakis","doi":"10.1007/s40477-024-00964-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Hypervolemia remains a problem in hemodialysis patients and is associated with hypertension, cardiovascular events and mortality. Lung Ultrasound (LUS) is a technique that detects hypervolemia via 4 different protocols depending on the number of sites checked on the chest wall. It has not been established which protocol should be preferred in the literature.</p><p><strong>Methods: </strong>This study included 68 hemodialysis patients from one Dialysis Unit. All the patients underwent LUS with every single protocol 30 min before and after the end of the middle-week dialysis session by a nephrology trainee. Patients' ideal weight was modified based on daily clinical practice rather than ultrasound findings.</p><p><strong>Results: </strong>Seventeen patients (25%) had ultrasound findings compatible with hypervolemia before the dialysis session, while eleven patients (16.2%) had still pulmonary congestion after the end of the session. These findings were similar to the number of patients considered hyperhydrated based on clinical criteria (10 patients). The rest protocols (8-zone, 6-zone and 4-zone protocol) considered fewer patients as hypervolemic.</p><p><strong>Conclusions: </strong>The 28-zone protocol can effectively detect hypervolemia and even classify the degree of it, although It is a time-consuming method. However, the other protocols can detect the hypervolemia in hemodialysis patients only when severe lung congestion exists. Their usefulness is limited in daily clinical practice in hemodialysis patients. More studies should be carried out for further and more reliable conclusions.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Scanning more corresponds to more accuracy in hemodialysis patients: 28-zone protocol's superior findings from an observational study.\",\"authors\":\"Christodoulos Keskinis, Stylianos Panagoutsos, Parthena Kyriklidou, Panagiotis Pateinakis, Eleni Manou, Eleni Soilemezi, Dorothea Papadopoulou, Ploumis Passadakis\",\"doi\":\"10.1007/s40477-024-00964-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>Hypervolemia remains a problem in hemodialysis patients and is associated with hypertension, cardiovascular events and mortality. Lung Ultrasound (LUS) is a technique that detects hypervolemia via 4 different protocols depending on the number of sites checked on the chest wall. It has not been established which protocol should be preferred in the literature.</p><p><strong>Methods: </strong>This study included 68 hemodialysis patients from one Dialysis Unit. All the patients underwent LUS with every single protocol 30 min before and after the end of the middle-week dialysis session by a nephrology trainee. Patients' ideal weight was modified based on daily clinical practice rather than ultrasound findings.</p><p><strong>Results: </strong>Seventeen patients (25%) had ultrasound findings compatible with hypervolemia before the dialysis session, while eleven patients (16.2%) had still pulmonary congestion after the end of the session. These findings were similar to the number of patients considered hyperhydrated based on clinical criteria (10 patients). The rest protocols (8-zone, 6-zone and 4-zone protocol) considered fewer patients as hypervolemic.</p><p><strong>Conclusions: </strong>The 28-zone protocol can effectively detect hypervolemia and even classify the degree of it, although It is a time-consuming method. However, the other protocols can detect the hypervolemia in hemodialysis patients only when severe lung congestion exists. Their usefulness is limited in daily clinical practice in hemodialysis patients. More studies should be carried out for further and more reliable conclusions.</p>\",\"PeriodicalId\":51528,\"journal\":{\"name\":\"Journal of Ultrasound\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ultrasound\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s40477-024-00964-y\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-024-00964-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:高血容量仍然是血液透析患者的一个问题,与高血压、心血管事件和死亡率有关。肺部超声波(LUS)是一种通过四种不同方案检测高血容量的技术,具体方案取决于胸壁检查部位的数量。文献中尚未确定哪种方案更可取:本研究包括来自一个透析室的 68 名血液透析患者。所有患者均在一周透析疗程中期结束前后 30 分钟接受了由一名肾内科见习医师进行的 LUS 检查。患者的理想体重根据日常临床实践而非超声检查结果进行调整:17名患者(25%)在透析前的超声检查结果与高血容量症相符,而11名患者(16.2%)在透析结束后仍有肺充血。这些结果与根据临床标准被认为患有高血容量症的患者人数(10 人)相似。其余方案(8 区、6 区和 4 区方案)被视为高血容量的患者人数较少:结论:28 区方案能有效检测出高血容量,甚至能对高血容量程度进行分类,尽管这种方法耗时较长。然而,其他方案只有在存在严重肺充血的情况下才能检测出血液透析患者的高血容量。这些方法在血液透析患者的日常临床实践中作用有限。应开展更多研究,以得出更可靠的结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Scanning more corresponds to more accuracy in hemodialysis patients: 28-zone protocol's superior findings from an observational study.

Aims: Hypervolemia remains a problem in hemodialysis patients and is associated with hypertension, cardiovascular events and mortality. Lung Ultrasound (LUS) is a technique that detects hypervolemia via 4 different protocols depending on the number of sites checked on the chest wall. It has not been established which protocol should be preferred in the literature.

Methods: This study included 68 hemodialysis patients from one Dialysis Unit. All the patients underwent LUS with every single protocol 30 min before and after the end of the middle-week dialysis session by a nephrology trainee. Patients' ideal weight was modified based on daily clinical practice rather than ultrasound findings.

Results: Seventeen patients (25%) had ultrasound findings compatible with hypervolemia before the dialysis session, while eleven patients (16.2%) had still pulmonary congestion after the end of the session. These findings were similar to the number of patients considered hyperhydrated based on clinical criteria (10 patients). The rest protocols (8-zone, 6-zone and 4-zone protocol) considered fewer patients as hypervolemic.

Conclusions: The 28-zone protocol can effectively detect hypervolemia and even classify the degree of it, although It is a time-consuming method. However, the other protocols can detect the hypervolemia in hemodialysis patients only when severe lung congestion exists. Their usefulness is limited in daily clinical practice in hemodialysis patients. More studies should be carried out for further and more reliable conclusions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Ultrasound
Journal of Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
15.00%
发文量
133
期刊介绍: The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信