Boyu Zhu, Lihang Zhu, Xinru Li, Ziyi Zhao, Jiayi Cao, Min Qi, Zhigang Gao, Lin Zhou, Bin Su
{"title":"用于糖尿病患者运动管理的可穿戴式集成微针电极贴。","authors":"Boyu Zhu, Lihang Zhu, Xinru Li, Ziyi Zhao, Jiayi Cao, Min Qi, Zhigang Gao, Lin Zhou, Bin Su","doi":"10.34133/research.0508","DOIUrl":null,"url":null,"abstract":"<p><p>Exercise is one of the preferred management strategies for diabetic patients, but the exercise mode including type, intensity, and duration time is quite different for each patient because of individual differences. Inadequate exercise has no effect on the blood glucose control, while overexercise may cause serious side effects, such as hypoglycemia and loss of blood glucose control. In this work, we report a closed-loop feedback mode for exercise management in diabetes. A minimally invasive, biocompatible microneedle electrode patch was fabricated and used for continuously monitoring the glucose in the interstitial fluid. Further, in conjunction with using a wireless electrochemical device, the glucose signals can be analyzed to output the potency of exercise and give advice on exercise management. A custom exercise given by this closed-loop feedback mode can reduce the used dose of insulin and avoid side effect during and after exercise. We believe that this work can provide a novel comprehensive guidance for diabetic patients.</p>","PeriodicalId":21120,"journal":{"name":"Research","volume":"7 ","pages":"0508"},"PeriodicalIF":11.0000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11491670/pdf/","citationCount":"0","resultStr":"{\"title\":\"A Wearable Integrated Microneedle Electrode Patch for Exercise Management in Diabetes.\",\"authors\":\"Boyu Zhu, Lihang Zhu, Xinru Li, Ziyi Zhao, Jiayi Cao, Min Qi, Zhigang Gao, Lin Zhou, Bin Su\",\"doi\":\"10.34133/research.0508\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Exercise is one of the preferred management strategies for diabetic patients, but the exercise mode including type, intensity, and duration time is quite different for each patient because of individual differences. Inadequate exercise has no effect on the blood glucose control, while overexercise may cause serious side effects, such as hypoglycemia and loss of blood glucose control. In this work, we report a closed-loop feedback mode for exercise management in diabetes. A minimally invasive, biocompatible microneedle electrode patch was fabricated and used for continuously monitoring the glucose in the interstitial fluid. Further, in conjunction with using a wireless electrochemical device, the glucose signals can be analyzed to output the potency of exercise and give advice on exercise management. A custom exercise given by this closed-loop feedback mode can reduce the used dose of insulin and avoid side effect during and after exercise. We believe that this work can provide a novel comprehensive guidance for diabetic patients.</p>\",\"PeriodicalId\":21120,\"journal\":{\"name\":\"Research\",\"volume\":\"7 \",\"pages\":\"0508\"},\"PeriodicalIF\":11.0000,\"publicationDate\":\"2024-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11491670/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Research\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.34133/research.0508\",\"RegionNum\":1,\"RegionCategory\":\"综合性期刊\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"Multidisciplinary\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.34133/research.0508","RegionNum":1,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"Multidisciplinary","Score":null,"Total":0}
A Wearable Integrated Microneedle Electrode Patch for Exercise Management in Diabetes.
Exercise is one of the preferred management strategies for diabetic patients, but the exercise mode including type, intensity, and duration time is quite different for each patient because of individual differences. Inadequate exercise has no effect on the blood glucose control, while overexercise may cause serious side effects, such as hypoglycemia and loss of blood glucose control. In this work, we report a closed-loop feedback mode for exercise management in diabetes. A minimally invasive, biocompatible microneedle electrode patch was fabricated and used for continuously monitoring the glucose in the interstitial fluid. Further, in conjunction with using a wireless electrochemical device, the glucose signals can be analyzed to output the potency of exercise and give advice on exercise management. A custom exercise given by this closed-loop feedback mode can reduce the used dose of insulin and avoid side effect during and after exercise. We believe that this work can provide a novel comprehensive guidance for diabetic patients.
期刊介绍:
Research serves as a global platform for academic exchange, collaboration, and technological advancements. This journal welcomes high-quality research contributions from any domain, with open arms to authors from around the globe.
Comprising fundamental research in the life and physical sciences, Research also highlights significant findings and issues in engineering and applied science. The journal proudly features original research articles, reviews, perspectives, and editorials, fostering a diverse and dynamic scholarly environment.