Behailu Taye, Roma Melkamu, Fitsumbrhan Tajebe, Ana Victoria Ibarra-Meneses, Desalegn Adane, Saba Atnafu, Mohammed Adem, Gashaw Adane, Mekibib Kassa, Mezgebu Silamsaw Asres, Johan van Griensven, Saskia van Henten, Myrthe Pareyn
{"title":"评估用于诊断埃塞俄比亚皮肤利什曼病的 Loopamp 利什曼病检测试剂盒。","authors":"Behailu Taye, Roma Melkamu, Fitsumbrhan Tajebe, Ana Victoria Ibarra-Meneses, Desalegn Adane, Saba Atnafu, Mohammed Adem, Gashaw Adane, Mekibib Kassa, Mezgebu Silamsaw Asres, Johan van Griensven, Saskia van Henten, Myrthe Pareyn","doi":"10.1186/s13071-024-06475-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cutaneous leishmaniasis (CL) in Ethiopia and some parts of Kenya is predominantly caused by Leishmania aethiopica. While skin-slit (SS) microscopy is routinely used for CL diagnosis, more sensitive molecular tests are available. The Loopamp™ Leishmania detection kit (Loopamp) is a robust loop-mediated isothermal amplification (LAMP) assay with the potential for implementation in primary healthcare facilities. In this study, we comparatively assessed the diagnostic accuracy of four methods currently used to diagnose CL: Loopamp, kinetoplast DNA (kDNA) PCR, spliced leader RNA (SL-RNA) PCR and SS microscopy.</p><p><strong>Methods: </strong>A study on 122 stored tape disc samples of suspected CL patients was conducted in Gondar, northwestern Ethiopia. Routine SS microscopy results were obtained from all patients. Total nucleic acids were extracted from the tapes and subjected to PCR testing targeting kDNA and SL-RNA, and Loopamp. Diagnostic accuracy was calculated with SS microscopy as a reference test. The limit of detection (LoD) of Loopamp and kDNA PCR were determined for cultured L. aethiopica and Leishmania donovani.</p><p><strong>Results: </strong>Of the 122 patients, 64 (52.5%) were identified as CL cases based on SS microscopy. Although the PCR tests showed a sensitivity of 95.3% (95% confidence interval [CI] 91.6-99.1), Loopamp only had 48.4% (95% CI 39.6-57.3) sensitivity and 87.9% (95% CI 82.1-93.7) specificity. The LoD of Loopamp for L. donovani was 100-fold lower (20 fg/µl) than that for L. aethiopica (2 pg/µl).</p><p><strong>Conclusions: </strong>The Loopamp™ Leishmania detection kit is not suitable for the diagnosis of CL in Ethiopia, presumably due to a primer mismatch with the L. aethiopica 18S rRNA target. Further research is needed to develop a simple and sensitive point-of-care test that allows the decentralization of CL diagnosis in Ethiopia.</p>","PeriodicalId":19793,"journal":{"name":"Parasites & Vectors","volume":null,"pages":null},"PeriodicalIF":3.0000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11481786/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Loopamp Leishmania detection kit for the diagnosis of cutaneous leishmaniasis in Ethiopia.\",\"authors\":\"Behailu Taye, Roma Melkamu, Fitsumbrhan Tajebe, Ana Victoria Ibarra-Meneses, Desalegn Adane, Saba Atnafu, Mohammed Adem, Gashaw Adane, Mekibib Kassa, Mezgebu Silamsaw Asres, Johan van Griensven, Saskia van Henten, Myrthe Pareyn\",\"doi\":\"10.1186/s13071-024-06475-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Cutaneous leishmaniasis (CL) in Ethiopia and some parts of Kenya is predominantly caused by Leishmania aethiopica. While skin-slit (SS) microscopy is routinely used for CL diagnosis, more sensitive molecular tests are available. The Loopamp™ Leishmania detection kit (Loopamp) is a robust loop-mediated isothermal amplification (LAMP) assay with the potential for implementation in primary healthcare facilities. In this study, we comparatively assessed the diagnostic accuracy of four methods currently used to diagnose CL: Loopamp, kinetoplast DNA (kDNA) PCR, spliced leader RNA (SL-RNA) PCR and SS microscopy.</p><p><strong>Methods: </strong>A study on 122 stored tape disc samples of suspected CL patients was conducted in Gondar, northwestern Ethiopia. Routine SS microscopy results were obtained from all patients. Total nucleic acids were extracted from the tapes and subjected to PCR testing targeting kDNA and SL-RNA, and Loopamp. Diagnostic accuracy was calculated with SS microscopy as a reference test. The limit of detection (LoD) of Loopamp and kDNA PCR were determined for cultured L. aethiopica and Leishmania donovani.</p><p><strong>Results: </strong>Of the 122 patients, 64 (52.5%) were identified as CL cases based on SS microscopy. Although the PCR tests showed a sensitivity of 95.3% (95% confidence interval [CI] 91.6-99.1), Loopamp only had 48.4% (95% CI 39.6-57.3) sensitivity and 87.9% (95% CI 82.1-93.7) specificity. The LoD of Loopamp for L. donovani was 100-fold lower (20 fg/µl) than that for L. aethiopica (2 pg/µl).</p><p><strong>Conclusions: </strong>The Loopamp™ Leishmania detection kit is not suitable for the diagnosis of CL in Ethiopia, presumably due to a primer mismatch with the L. aethiopica 18S rRNA target. Further research is needed to develop a simple and sensitive point-of-care test that allows the decentralization of CL diagnosis in Ethiopia.</p>\",\"PeriodicalId\":19793,\"journal\":{\"name\":\"Parasites & Vectors\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11481786/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Parasites & Vectors\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s13071-024-06475-3\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"PARASITOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Parasites & Vectors","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13071-024-06475-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PARASITOLOGY","Score":null,"Total":0}
Evaluation of Loopamp Leishmania detection kit for the diagnosis of cutaneous leishmaniasis in Ethiopia.
Background: Cutaneous leishmaniasis (CL) in Ethiopia and some parts of Kenya is predominantly caused by Leishmania aethiopica. While skin-slit (SS) microscopy is routinely used for CL diagnosis, more sensitive molecular tests are available. The Loopamp™ Leishmania detection kit (Loopamp) is a robust loop-mediated isothermal amplification (LAMP) assay with the potential for implementation in primary healthcare facilities. In this study, we comparatively assessed the diagnostic accuracy of four methods currently used to diagnose CL: Loopamp, kinetoplast DNA (kDNA) PCR, spliced leader RNA (SL-RNA) PCR and SS microscopy.
Methods: A study on 122 stored tape disc samples of suspected CL patients was conducted in Gondar, northwestern Ethiopia. Routine SS microscopy results were obtained from all patients. Total nucleic acids were extracted from the tapes and subjected to PCR testing targeting kDNA and SL-RNA, and Loopamp. Diagnostic accuracy was calculated with SS microscopy as a reference test. The limit of detection (LoD) of Loopamp and kDNA PCR were determined for cultured L. aethiopica and Leishmania donovani.
Results: Of the 122 patients, 64 (52.5%) were identified as CL cases based on SS microscopy. Although the PCR tests showed a sensitivity of 95.3% (95% confidence interval [CI] 91.6-99.1), Loopamp only had 48.4% (95% CI 39.6-57.3) sensitivity and 87.9% (95% CI 82.1-93.7) specificity. The LoD of Loopamp for L. donovani was 100-fold lower (20 fg/µl) than that for L. aethiopica (2 pg/µl).
Conclusions: The Loopamp™ Leishmania detection kit is not suitable for the diagnosis of CL in Ethiopia, presumably due to a primer mismatch with the L. aethiopica 18S rRNA target. Further research is needed to develop a simple and sensitive point-of-care test that allows the decentralization of CL diagnosis in Ethiopia.
期刊介绍:
Parasites & Vectors is an open access, peer-reviewed online journal dealing with the biology of parasites, parasitic diseases, intermediate hosts, vectors and vector-borne pathogens. Manuscripts published in this journal will be available to all worldwide, with no barriers to access, immediately following acceptance. However, authors retain the copyright of their material and may use it, or distribute it, as they wish.
Manuscripts on all aspects of the basic and applied biology of parasites, intermediate hosts, vectors and vector-borne pathogens will be considered. In addition to the traditional and well-established areas of science in these fields, we also aim to provide a vehicle for publication of the rapidly developing resources and technology in parasite, intermediate host and vector genomics and their impacts on biological research. We are able to publish large datasets and extensive results, frequently associated with genomic and post-genomic technologies, which are not readily accommodated in traditional journals. Manuscripts addressing broader issues, for example economics, social sciences and global climate change in relation to parasites, vectors and disease control, are also welcomed.