单色调复合材料有可能模仿其他单色调复合材料的颜色、明度、色度和色调吗?体外研究。

IF 1.4 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
M Buldur, G Ayan
{"title":"单色调复合材料有可能模仿其他单色调复合材料的颜色、明度、色度和色调吗?体外研究。","authors":"M Buldur, G Ayan","doi":"10.2341/24-059-L","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to assess color matching post-repair using the same or different single-shade composites of three distinct composite resin materials (Omnichroma-OM, ZenChroma-ZC, and Charisma Topaz One-CTO) following aging in coffee solution and distilled water. Evaluation focused on color change parameters (∆E00, ∆L00, ∆C00, and ∆H00).</p><p><strong>Methods and materials: </strong>Specimens were prepared in disk shape with a diameter of 8 mm and a height of 2 mm (n=180). Half of each composite group was immersed in distilled water, while the other half was immersed in coffee solution for 12 days each (n=90). After aging, cylindrical cavities with a diameter of 4 mm and a depth of 1 mm were prepared at the center of the specimens. The cavities were repaired with both themselves and other composite resins (n=10). Color measurements of the specimens were performed using VITA Easyshade 5 (VITA Zahnfabrik, Bad Säckingen, Germany) at the following time points: baseline (T0), after aging (12 days) (T1), immediately after repair (T2), one day after repair (T3), one week after repair (T4), and one month after repair (T5).</p><p><strong>Results: </strong>Statistically significant differences were found in the mean ΔE00 measurements among the study groups at all time points for each of the three composite resins (p<0.05). Similarly, statistically significant differences were found in the mean ΔE00 measurements over time for each of the three composite resins in each study group (p<0.05). The baseline measurements of materials repaired with themselves in the distilled water groups and the final measurements of materials repaired with themselves in the coffee groups were found to be within acceptable ∆E00limits. At the end of the study, only CTO repaired with OM showed acceptable color matching with different composites in both coffee and distilled water groups.</p><p><strong>Conclusions: </strong>Acceptable color matching was achieved when using the same material for repair in specimens aged in distilled water and coffee. However, variations in matching were observed when different materials were used for repair, indicating the need for ongoing monitoring. Contributions of ΔL00, ΔC00, and ΔH00 values to color differences vary depending on the resins and repair process and change over time.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"691-703"},"PeriodicalIF":1.4000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Is It Possible for Single-shade Composites to Mimic the Color, Lightness, Chroma, and Hue of Other Single-shade Composites? An In Vitro Study.\",\"authors\":\"M Buldur, G Ayan\",\"doi\":\"10.2341/24-059-L\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This study aimed to assess color matching post-repair using the same or different single-shade composites of three distinct composite resin materials (Omnichroma-OM, ZenChroma-ZC, and Charisma Topaz One-CTO) following aging in coffee solution and distilled water. Evaluation focused on color change parameters (∆E00, ∆L00, ∆C00, and ∆H00).</p><p><strong>Methods and materials: </strong>Specimens were prepared in disk shape with a diameter of 8 mm and a height of 2 mm (n=180). Half of each composite group was immersed in distilled water, while the other half was immersed in coffee solution for 12 days each (n=90). After aging, cylindrical cavities with a diameter of 4 mm and a depth of 1 mm were prepared at the center of the specimens. The cavities were repaired with both themselves and other composite resins (n=10). Color measurements of the specimens were performed using VITA Easyshade 5 (VITA Zahnfabrik, Bad Säckingen, Germany) at the following time points: baseline (T0), after aging (12 days) (T1), immediately after repair (T2), one day after repair (T3), one week after repair (T4), and one month after repair (T5).</p><p><strong>Results: </strong>Statistically significant differences were found in the mean ΔE00 measurements among the study groups at all time points for each of the three composite resins (p<0.05). Similarly, statistically significant differences were found in the mean ΔE00 measurements over time for each of the three composite resins in each study group (p<0.05). The baseline measurements of materials repaired with themselves in the distilled water groups and the final measurements of materials repaired with themselves in the coffee groups were found to be within acceptable ∆E00limits. At the end of the study, only CTO repaired with OM showed acceptable color matching with different composites in both coffee and distilled water groups.</p><p><strong>Conclusions: </strong>Acceptable color matching was achieved when using the same material for repair in specimens aged in distilled water and coffee. However, variations in matching were observed when different materials were used for repair, indicating the need for ongoing monitoring. Contributions of ΔL00, ΔC00, and ΔH00 values to color differences vary depending on the resins and repair process and change over time.</p>\",\"PeriodicalId\":19502,\"journal\":{\"name\":\"Operative dentistry\",\"volume\":\" \",\"pages\":\"691-703\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Operative dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2341/24-059-L\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/24-059-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在评估三种不同的复合树脂材料(Omnichroma-OM、ZenChroma-ZC 和 Charisma Topaz One-CTO)在咖啡溶液和蒸馏水中老化后,使用相同或不同的单色复合材料进行修复后的颜色匹配。评估的重点是颜色变化参数(ΔE00、ΔL00、ΔC00 和 ΔH00):制备直径为 8 毫米、高度为 2 毫米的圆盘状试样(n=180)。每组复合材料的一半浸泡在蒸馏水中,另一半浸泡在咖啡溶液中各 12 天(n=90)。老化后,在试样中心制备直径为 4 毫米、深度为 1 毫米的圆柱形空腔。龋洞用自身和其他复合树脂修复(10 个)。使用 VITA Easyshade 5(VITA Zahnfabrik,德国 Bad Säckingen)在以下时间点测量试样的颜色:基线(T0)、老化(12 天)后(T1)、修复后立即(T2)、修复后一天(T3)、修复后一周(T4)和修复后一个月(T5):结果:对于三种复合树脂,各研究组在所有时间点的平均 ΔE00 测量值均存在明显的统计学差异(p 结论:在使用复合树脂时,色泽匹配度是可以接受的:在蒸馏水和咖啡中老化的试样中使用相同的材料进行修复时,可达到可接受的颜色匹配。然而,当使用不同的材料进行修复时,匹配度会出现差异,这表明有必要进行持续监测。ΔL00、ΔC00 和 ΔH00 值对颜色差异的影响因树脂和修复过程而异,并随着时间的推移而变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Is It Possible for Single-shade Composites to Mimic the Color, Lightness, Chroma, and Hue of Other Single-shade Composites? An In Vitro Study.

Objectives: This study aimed to assess color matching post-repair using the same or different single-shade composites of three distinct composite resin materials (Omnichroma-OM, ZenChroma-ZC, and Charisma Topaz One-CTO) following aging in coffee solution and distilled water. Evaluation focused on color change parameters (∆E00, ∆L00, ∆C00, and ∆H00).

Methods and materials: Specimens were prepared in disk shape with a diameter of 8 mm and a height of 2 mm (n=180). Half of each composite group was immersed in distilled water, while the other half was immersed in coffee solution for 12 days each (n=90). After aging, cylindrical cavities with a diameter of 4 mm and a depth of 1 mm were prepared at the center of the specimens. The cavities were repaired with both themselves and other composite resins (n=10). Color measurements of the specimens were performed using VITA Easyshade 5 (VITA Zahnfabrik, Bad Säckingen, Germany) at the following time points: baseline (T0), after aging (12 days) (T1), immediately after repair (T2), one day after repair (T3), one week after repair (T4), and one month after repair (T5).

Results: Statistically significant differences were found in the mean ΔE00 measurements among the study groups at all time points for each of the three composite resins (p<0.05). Similarly, statistically significant differences were found in the mean ΔE00 measurements over time for each of the three composite resins in each study group (p<0.05). The baseline measurements of materials repaired with themselves in the distilled water groups and the final measurements of materials repaired with themselves in the coffee groups were found to be within acceptable ∆E00limits. At the end of the study, only CTO repaired with OM showed acceptable color matching with different composites in both coffee and distilled water groups.

Conclusions: Acceptable color matching was achieved when using the same material for repair in specimens aged in distilled water and coffee. However, variations in matching were observed when different materials were used for repair, indicating the need for ongoing monitoring. Contributions of ΔL00, ΔC00, and ΔH00 values to color differences vary depending on the resins and repair process and change over time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Operative dentistry
Operative dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
9.10%
发文量
124
审稿时长
6-12 weeks
期刊介绍: Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts. One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use. The journal does not accept any advertising but you will find postings for faculty positions. Additionally, the journal also does not rent, sell or otherwise allow its subscriber list to be used by any other entity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信