用于轮状磁共振成像的梯度诱导采样误差的双参数预扫描校准。

IF 3 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Magnetic Resonance in Medicine Pub Date : 2025-03-01 Epub Date: 2024-10-22 DOI:10.1002/mrm.30355
Peter Latta, Radovan Jiřík, Jiří Vitouš, Ondřej Macíček, Lubomír Vojtíšek, Ivan Rektor, Michal Standara, Jan Křístek, Zenon Starčuk
{"title":"用于轮状磁共振成像的梯度诱导采样误差的双参数预扫描校准。","authors":"Peter Latta, Radovan Jiřík, Jiří Vitouš, Ondřej Macíček, Lubomír Vojtíšek, Ivan Rektor, Michal Standara, Jan Křístek, Zenon Starčuk","doi":"10.1002/mrm.30355","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to develop a simple, robust, and easy-to-use calibration procedure for correcting misalignments in rosette MRI k-space sampling, with the objective of producing images with minimal artifacts.</p><p><strong>Methods: </strong>Quick automatic calibration scans were proposed for the beginning of the measurement to collect information on the time course of the rosette acquisition trajectory. A two-parameter model was devised to match the measured time-varying readout gradient delays and approximate the actual rosette sampling trajectory. The proposed calibration approach was implemented, and performance assessment was conducted on both phantoms and human subjects.</p><p><strong>Results: </strong>The fidelity of phantom and in vivo images exhibited significant improvement compared with uncorrected rosette data. The two-parameter calibration approach also demonstrated enhanced precision and reliability, as evidenced by quantitative <math> <semantics> <mrow><msubsup><mi>T</mi> <mn>2</mn> <mo>*</mo></msubsup> </mrow> <annotation>$$ {\\mathrm{T}}_2^{\\ast } $$</annotation></semantics> </math> relaxometry analyses.</p><p><strong>Conclusion: </strong>Adequate correction of data sampling is a crucial step in rosette MRI. The presented experimental results underscore the robustness, ease of implementation, and suitability for routine experimental use of the proposed two-parameter rosette trajectory calibration approach.</p>","PeriodicalId":18065,"journal":{"name":"Magnetic Resonance in Medicine","volume":" ","pages":"1285-1297"},"PeriodicalIF":3.0000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11680729/pdf/","citationCount":"0","resultStr":"{\"title\":\"Two-parametric prescan calibration of gradient-induced sampling errors for rosette MRI.\",\"authors\":\"Peter Latta, Radovan Jiřík, Jiří Vitouš, Ondřej Macíček, Lubomír Vojtíšek, Ivan Rektor, Michal Standara, Jan Křístek, Zenon Starčuk\",\"doi\":\"10.1002/mrm.30355\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this study was to develop a simple, robust, and easy-to-use calibration procedure for correcting misalignments in rosette MRI k-space sampling, with the objective of producing images with minimal artifacts.</p><p><strong>Methods: </strong>Quick automatic calibration scans were proposed for the beginning of the measurement to collect information on the time course of the rosette acquisition trajectory. A two-parameter model was devised to match the measured time-varying readout gradient delays and approximate the actual rosette sampling trajectory. The proposed calibration approach was implemented, and performance assessment was conducted on both phantoms and human subjects.</p><p><strong>Results: </strong>The fidelity of phantom and in vivo images exhibited significant improvement compared with uncorrected rosette data. The two-parameter calibration approach also demonstrated enhanced precision and reliability, as evidenced by quantitative <math> <semantics> <mrow><msubsup><mi>T</mi> <mn>2</mn> <mo>*</mo></msubsup> </mrow> <annotation>$$ {\\\\mathrm{T}}_2^{\\\\ast } $$</annotation></semantics> </math> relaxometry analyses.</p><p><strong>Conclusion: </strong>Adequate correction of data sampling is a crucial step in rosette MRI. The presented experimental results underscore the robustness, ease of implementation, and suitability for routine experimental use of the proposed two-parameter rosette trajectory calibration approach.</p>\",\"PeriodicalId\":18065,\"journal\":{\"name\":\"Magnetic Resonance in Medicine\",\"volume\":\" \",\"pages\":\"1285-1297\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2025-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11680729/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic Resonance in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/mrm.30355\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/mrm.30355","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/22 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在开发一种简单、稳健且易于使用的校准程序,用于校正轮状磁共振成像 k 空间采样中的错位,目的是生成伪影最小的图像:方法:建议在测量开始时进行快速自动校准扫描,以收集花环采集轨迹的时间过程信息。设计了一个双参数模型,以匹配测量到的时变读出梯度延迟,并接近实际的玫瑰花采集轨迹。提出的校准方法已付诸实施,并在模型和人体上进行了性能评估:结果:与未校正的玫瑰花瓣数据相比,模型和活体图像的保真度有了显著提高。定量 T 2 * $$ {\mathrm{T}}_2^{\ast }$ 弛豫测量分析表明,双参数校准方法还提高了精确度和可靠性。$$ 松弛测量分析:结论:数据采样的充分校正是莲座磁共振成像的关键步骤。所展示的实验结果证明了所提出的双参数轮状轨迹校准方法的稳健性、易实施性和常规实验使用的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Two-parametric prescan calibration of gradient-induced sampling errors for rosette MRI.

Purpose: The aim of this study was to develop a simple, robust, and easy-to-use calibration procedure for correcting misalignments in rosette MRI k-space sampling, with the objective of producing images with minimal artifacts.

Methods: Quick automatic calibration scans were proposed for the beginning of the measurement to collect information on the time course of the rosette acquisition trajectory. A two-parameter model was devised to match the measured time-varying readout gradient delays and approximate the actual rosette sampling trajectory. The proposed calibration approach was implemented, and performance assessment was conducted on both phantoms and human subjects.

Results: The fidelity of phantom and in vivo images exhibited significant improvement compared with uncorrected rosette data. The two-parameter calibration approach also demonstrated enhanced precision and reliability, as evidenced by quantitative T 2 * $$ {\mathrm{T}}_2^{\ast } $$ relaxometry analyses.

Conclusion: Adequate correction of data sampling is a crucial step in rosette MRI. The presented experimental results underscore the robustness, ease of implementation, and suitability for routine experimental use of the proposed two-parameter rosette trajectory calibration approach.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.70
自引率
24.20%
发文量
376
审稿时长
2-4 weeks
期刊介绍: Magnetic Resonance in Medicine (Magn Reson Med) is an international journal devoted to the publication of original investigations concerned with all aspects of the development and use of nuclear magnetic resonance and electron paramagnetic resonance techniques for medical applications. Reports of original investigations in the areas of mathematics, computing, engineering, physics, biophysics, chemistry, biochemistry, and physiology directly relevant to magnetic resonance will be accepted, as well as methodology-oriented clinical studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信