使用热塑性塑料和三维打印手术导板植入种植体的准确性比较评估:随机对照试验。

Q2 Dentistry
Firasat Husain, Vishakha Grover, Nandini Bhaskar, Ashish Jain
{"title":"使用热塑性塑料和三维打印手术导板植入种植体的准确性比较评估:随机对照试验。","authors":"Firasat Husain, Vishakha Grover, Nandini Bhaskar, Ashish Jain","doi":"10.4103/jisp.jisp_256_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The current study was planned to evaluate the accuracy of dental implant placement with two different types of surgical guides: Thermoplastic and three-dimensional (3D) printed.</p><p><strong>Materials and methods: </strong>A total of 32 implants were placed in 20 healthy, partially dentate individuals with an isolated single missing tooth. The implant sites were randomly allocated into two treatment groups: Group A (thermoplastic implant surgical guide, <i>n</i> = 16 implants) and Group B (3D printed implant surgical guide, <i>n</i> = 16 implants). All the cases in both groups were digitally planned according to a defined protocol, and a comparison of the planned and actual implant positions was performed using the medical image analysis software. The differences in the outcome variables, i.e., angular deviation (AD), 3D error at the entry, 3D error at the apex (3D EA), vertical deviation (VD), and composite deviation, were statistically analyzed.</p><p><strong>Results: </strong>All the outcome variables showed improvements, but statistically significant improvement was shown by AD (<i>P</i> = 0.005), 3D EA (<i>P</i> = 0.01), and VD (<i>P</i> = 0.007). The mean and standard deviation (SD) for AD, (3D EA), and VD were 5.58° ±1.93°, 0.96 ± 0.32 mm, and 0.58 ± 0.36 mm, respectively, for group A. The mean and SD for AD, (3D EA), and VD were 3.94° ± 0.64°, 0.64 ± 0.35 mm, and 0.29 ± 0.13 mm, respectively, for group B (<i>P</i> < 0.05).</p><p><strong>Conclusion: </strong>Within the limits of the study, dental implants placed using 3D-printed surgical guides were positioned clinically with greater accuracy, and fewer deviations were observed from their presurgical planned positions as compared to the thermoplastic surgical guides.</p>","PeriodicalId":15890,"journal":{"name":"Journal of Indian Society of Periodontology","volume":"28 2","pages":"244-251"},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11472977/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparative evaluation of accuracy of implants placed with thermoplastic and three-dimensional-printed surgical guides: A randomized controlled trial.\",\"authors\":\"Firasat Husain, Vishakha Grover, Nandini Bhaskar, Ashish Jain\",\"doi\":\"10.4103/jisp.jisp_256_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The current study was planned to evaluate the accuracy of dental implant placement with two different types of surgical guides: Thermoplastic and three-dimensional (3D) printed.</p><p><strong>Materials and methods: </strong>A total of 32 implants were placed in 20 healthy, partially dentate individuals with an isolated single missing tooth. The implant sites were randomly allocated into two treatment groups: Group A (thermoplastic implant surgical guide, <i>n</i> = 16 implants) and Group B (3D printed implant surgical guide, <i>n</i> = 16 implants). All the cases in both groups were digitally planned according to a defined protocol, and a comparison of the planned and actual implant positions was performed using the medical image analysis software. The differences in the outcome variables, i.e., angular deviation (AD), 3D error at the entry, 3D error at the apex (3D EA), vertical deviation (VD), and composite deviation, were statistically analyzed.</p><p><strong>Results: </strong>All the outcome variables showed improvements, but statistically significant improvement was shown by AD (<i>P</i> = 0.005), 3D EA (<i>P</i> = 0.01), and VD (<i>P</i> = 0.007). The mean and standard deviation (SD) for AD, (3D EA), and VD were 5.58° ±1.93°, 0.96 ± 0.32 mm, and 0.58 ± 0.36 mm, respectively, for group A. The mean and SD for AD, (3D EA), and VD were 3.94° ± 0.64°, 0.64 ± 0.35 mm, and 0.29 ± 0.13 mm, respectively, for group B (<i>P</i> < 0.05).</p><p><strong>Conclusion: </strong>Within the limits of the study, dental implants placed using 3D-printed surgical guides were positioned clinically with greater accuracy, and fewer deviations were observed from their presurgical planned positions as compared to the thermoplastic surgical guides.</p>\",\"PeriodicalId\":15890,\"journal\":{\"name\":\"Journal of Indian Society of Periodontology\",\"volume\":\"28 2\",\"pages\":\"244-251\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11472977/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Indian Society of Periodontology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jisp.jisp_256_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian Society of Periodontology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jisp.jisp_256_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/31 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

研究背景本研究计划评估使用两种不同类型的手术导板植入牙科植入物的准确性:材料和方法:在 20 名健康、部分牙齿缺失、单颗牙齿缺失的患者身上共植入了 32 颗种植体。这些种植体被随机分配到两个治疗组:A组(热塑性种植体手术导板,n = 16颗种植体)和B组(3D打印种植体手术导板,n = 16颗种植体)。两组的所有病例均按照既定方案进行数字化规划,并使用医学图像分析软件对规划和实际种植体位置进行比较。对结果变量,即角度偏差(AD)、入口三维误差、顶点三维误差(3D EA)、垂直偏差(VD)和综合偏差的差异进行了统计分析:结果:所有结果变量均有改善,但 AD(P = 0.005)、3D EA(P = 0.01)和 VD(P = 0.007)有显著改善。A 组 AD、(三维 EA)和 VD 的平均值和标准差(SD)分别为 5.58°±1.93°、0.96±0.32 mm 和 0.58±0.36 mm;B 组 AD、(三维 EA)和 VD 的平均值和标准差(SD)分别为 3.94°±0.64°、0.64±0.35 mm 和 0.29±0.13 mm(P <0.05):在研究范围内,与热塑手术导板相比,使用 3D 打印手术导板植入的牙科种植体在临床上的定位精度更高,与手术前计划位置的偏差也更小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative evaluation of accuracy of implants placed with thermoplastic and three-dimensional-printed surgical guides: A randomized controlled trial.

Background: The current study was planned to evaluate the accuracy of dental implant placement with two different types of surgical guides: Thermoplastic and three-dimensional (3D) printed.

Materials and methods: A total of 32 implants were placed in 20 healthy, partially dentate individuals with an isolated single missing tooth. The implant sites were randomly allocated into two treatment groups: Group A (thermoplastic implant surgical guide, n = 16 implants) and Group B (3D printed implant surgical guide, n = 16 implants). All the cases in both groups were digitally planned according to a defined protocol, and a comparison of the planned and actual implant positions was performed using the medical image analysis software. The differences in the outcome variables, i.e., angular deviation (AD), 3D error at the entry, 3D error at the apex (3D EA), vertical deviation (VD), and composite deviation, were statistically analyzed.

Results: All the outcome variables showed improvements, but statistically significant improvement was shown by AD (P = 0.005), 3D EA (P = 0.01), and VD (P = 0.007). The mean and standard deviation (SD) for AD, (3D EA), and VD were 5.58° ±1.93°, 0.96 ± 0.32 mm, and 0.58 ± 0.36 mm, respectively, for group A. The mean and SD for AD, (3D EA), and VD were 3.94° ± 0.64°, 0.64 ± 0.35 mm, and 0.29 ± 0.13 mm, respectively, for group B (P < 0.05).

Conclusion: Within the limits of the study, dental implants placed using 3D-printed surgical guides were positioned clinically with greater accuracy, and fewer deviations were observed from their presurgical planned positions as compared to the thermoplastic surgical guides.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
87
审稿时长
44 weeks
期刊介绍: The Journal of Indian Society of Periodontology publishes original scientific articles to support practice , education and research in the dental specialty of periodontology and oral implantology. Journal of Indian Society of Periodontology (JISP), is the official publication of the Society and is managed and brought out by the Editor of the society. The journal is published Bimonthly with special issues being brought out for specific occasions. The ISP had a bulletin as its publication for a large number of years and was enhanced as a Journal a few years ago
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信