I-Min Chiu, Po-Jung Wu, Huan Zhang, J Weston Hughes, Albert J Rogers, Laleh Jalilian, Marco Perez, Chun-Hung Richard Lin, Chien-Te Lee, James Zou, David Ouyang
{"title":"利用人工智能智能手表心电图监测血清钾。","authors":"I-Min Chiu, Po-Jung Wu, Huan Zhang, J Weston Hughes, Albert J Rogers, Laleh Jalilian, Marco Perez, Chun-Hung Richard Lin, Chien-Te Lee, James Zou, David Ouyang","doi":"10.1016/j.jacep.2024.07.023","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Hyperkalemia, characterized by elevated serum potassium levels, heightens the risk of sudden cardiac death, particularly increasing risk for individuals with chronic kidney disease and end-stage renal disease (ESRD). Traditional laboratory test monitoring is resource-heavy, invasive, and unable to provide continuous tracking. Wearable technologies like smartwatches with electrocardiogram (ECG) capabilities are emerging as valuable tools for remote monitoring, potentially allowing for personalized monitoring with artificial intelligence (AI)-ECG interpretation.</p><p><strong>Objectives: </strong>The purpose of this study was to develop an AI-ECG algorithm to predict serum potassium level in ESRD patients with smartwatch-generated ECG waveforms.</p><p><strong>Methods: </strong>A cohort of 152,508 patients with 293,557 ECGs paired serum potassium levels obtained within 1 hour at Cedars Sinai Medical Center was used to train an AI-ECG model (\"Kardio-Net\") to predict serum potassium level. The model was further fine-tuned on 4,337 ECGs from 1,463 patients with ESRD using inputs from 12- and single-lead ECGs. Kardio-Net was evaluated in held-out test cohorts from Cedars Sinai Medical Center and Stanford Healthcare (SHC) as well as a prospective international cohort of 40 ESRD patients with smartwatch ECGs at Chang Gung Memorial Hospital.</p><p><strong>Results: </strong>The Kardio-Net, when applied to 12-lead ECGs, identified severe hyperkalemia (>6.5 mEq/L) with an AUC of 0.852 (95% CI: 0.745-0.956) and a mean absolute error (MAE) of 0.527 mEq/L. In external validation at SHC, the model achieved an AUC of 0.849 (95% CI: 0.823-0.875) and an MAE of 0.599 mEq/L. For single-lead ECGs, Kardio-Net detected severe hyperkalemia with an AUC of 0.876 (95% CI: 0.765-0.987) in the primary cohort and had an MAE of 0.575 mEq/L. In the external SHC validation, the AUC was 0.807 (95% CI: 0.778-0.835) with an MAE of 0.740 mEq/L. Using prospectively obtained smartwatch data, the AUC was 0.831 (95% CI: 0.693-0.975), with an MAE of 0.580 mEq/L.</p><p><strong>Conclusions: </strong>We validate a deep learning model to predict serum potassium levels from both 12-lead ECGs and single-lead smartwatch data, demonstrating its utility for remote monitoring of hyperkalemia.</p>","PeriodicalId":14573,"journal":{"name":"JACC. Clinical electrophysiology","volume":" ","pages":""},"PeriodicalIF":8.0000,"publicationDate":"2024-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Serum Potassium Monitoring Using AI-Enabled Smartwatch Electrocardiograms.\",\"authors\":\"I-Min Chiu, Po-Jung Wu, Huan Zhang, J Weston Hughes, Albert J Rogers, Laleh Jalilian, Marco Perez, Chun-Hung Richard Lin, Chien-Te Lee, James Zou, David Ouyang\",\"doi\":\"10.1016/j.jacep.2024.07.023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Hyperkalemia, characterized by elevated serum potassium levels, heightens the risk of sudden cardiac death, particularly increasing risk for individuals with chronic kidney disease and end-stage renal disease (ESRD). Traditional laboratory test monitoring is resource-heavy, invasive, and unable to provide continuous tracking. Wearable technologies like smartwatches with electrocardiogram (ECG) capabilities are emerging as valuable tools for remote monitoring, potentially allowing for personalized monitoring with artificial intelligence (AI)-ECG interpretation.</p><p><strong>Objectives: </strong>The purpose of this study was to develop an AI-ECG algorithm to predict serum potassium level in ESRD patients with smartwatch-generated ECG waveforms.</p><p><strong>Methods: </strong>A cohort of 152,508 patients with 293,557 ECGs paired serum potassium levels obtained within 1 hour at Cedars Sinai Medical Center was used to train an AI-ECG model (\\\"Kardio-Net\\\") to predict serum potassium level. The model was further fine-tuned on 4,337 ECGs from 1,463 patients with ESRD using inputs from 12- and single-lead ECGs. Kardio-Net was evaluated in held-out test cohorts from Cedars Sinai Medical Center and Stanford Healthcare (SHC) as well as a prospective international cohort of 40 ESRD patients with smartwatch ECGs at Chang Gung Memorial Hospital.</p><p><strong>Results: </strong>The Kardio-Net, when applied to 12-lead ECGs, identified severe hyperkalemia (>6.5 mEq/L) with an AUC of 0.852 (95% CI: 0.745-0.956) and a mean absolute error (MAE) of 0.527 mEq/L. In external validation at SHC, the model achieved an AUC of 0.849 (95% CI: 0.823-0.875) and an MAE of 0.599 mEq/L. For single-lead ECGs, Kardio-Net detected severe hyperkalemia with an AUC of 0.876 (95% CI: 0.765-0.987) in the primary cohort and had an MAE of 0.575 mEq/L. In the external SHC validation, the AUC was 0.807 (95% CI: 0.778-0.835) with an MAE of 0.740 mEq/L. Using prospectively obtained smartwatch data, the AUC was 0.831 (95% CI: 0.693-0.975), with an MAE of 0.580 mEq/L.</p><p><strong>Conclusions: </strong>We validate a deep learning model to predict serum potassium levels from both 12-lead ECGs and single-lead smartwatch data, demonstrating its utility for remote monitoring of hyperkalemia.</p>\",\"PeriodicalId\":14573,\"journal\":{\"name\":\"JACC. Clinical electrophysiology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":8.0000,\"publicationDate\":\"2024-09-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JACC. Clinical electrophysiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jacep.2024.07.023\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JACC. Clinical electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jacep.2024.07.023","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Serum Potassium Monitoring Using AI-Enabled Smartwatch Electrocardiograms.
Background: Hyperkalemia, characterized by elevated serum potassium levels, heightens the risk of sudden cardiac death, particularly increasing risk for individuals with chronic kidney disease and end-stage renal disease (ESRD). Traditional laboratory test monitoring is resource-heavy, invasive, and unable to provide continuous tracking. Wearable technologies like smartwatches with electrocardiogram (ECG) capabilities are emerging as valuable tools for remote monitoring, potentially allowing for personalized monitoring with artificial intelligence (AI)-ECG interpretation.
Objectives: The purpose of this study was to develop an AI-ECG algorithm to predict serum potassium level in ESRD patients with smartwatch-generated ECG waveforms.
Methods: A cohort of 152,508 patients with 293,557 ECGs paired serum potassium levels obtained within 1 hour at Cedars Sinai Medical Center was used to train an AI-ECG model ("Kardio-Net") to predict serum potassium level. The model was further fine-tuned on 4,337 ECGs from 1,463 patients with ESRD using inputs from 12- and single-lead ECGs. Kardio-Net was evaluated in held-out test cohorts from Cedars Sinai Medical Center and Stanford Healthcare (SHC) as well as a prospective international cohort of 40 ESRD patients with smartwatch ECGs at Chang Gung Memorial Hospital.
Results: The Kardio-Net, when applied to 12-lead ECGs, identified severe hyperkalemia (>6.5 mEq/L) with an AUC of 0.852 (95% CI: 0.745-0.956) and a mean absolute error (MAE) of 0.527 mEq/L. In external validation at SHC, the model achieved an AUC of 0.849 (95% CI: 0.823-0.875) and an MAE of 0.599 mEq/L. For single-lead ECGs, Kardio-Net detected severe hyperkalemia with an AUC of 0.876 (95% CI: 0.765-0.987) in the primary cohort and had an MAE of 0.575 mEq/L. In the external SHC validation, the AUC was 0.807 (95% CI: 0.778-0.835) with an MAE of 0.740 mEq/L. Using prospectively obtained smartwatch data, the AUC was 0.831 (95% CI: 0.693-0.975), with an MAE of 0.580 mEq/L.
Conclusions: We validate a deep learning model to predict serum potassium levels from both 12-lead ECGs and single-lead smartwatch data, demonstrating its utility for remote monitoring of hyperkalemia.
期刊介绍:
JACC: Clinical Electrophysiology is one of a family of specialist journals launched by the renowned Journal of the American College of Cardiology (JACC). It encompasses all aspects of the epidemiology, pathogenesis, diagnosis and treatment of cardiac arrhythmias. Submissions of original research and state-of-the-art reviews from cardiology, cardiovascular surgery, neurology, outcomes research, and related fields are encouraged. Experimental and preclinical work that directly relates to diagnostic or therapeutic interventions are also encouraged. In general, case reports will not be considered for publication.