Joo Won Choi, Yang Qiao, Tej I Mehta, Thomas M Clausen, Y Jonathan Zhang, Samuel Tsappidi, Ferdinand K Hui
{"title":"Vecta 46 中间导管用于远端中血管闭塞的机械血栓切除术:单中心经验。","authors":"Joo Won Choi, Yang Qiao, Tej I Mehta, Thomas M Clausen, Y Jonathan Zhang, Samuel Tsappidi, Ferdinand K Hui","doi":"10.1177/15910199241283513","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>With emerging evidence supporting the clinical efficacy and safety of mechanical thrombectomy (MT) for distal medium vessel occlusions (DMVOs), MT devices specifically designed to navigate through smaller caliber and more delicate tortuous distal cerebrovasculature are required. This study describes our single-center experience using the AXS Vecta 46 intermediate catheter for first-line thromboaspiration of DMVOs.</p><p><strong>Methods: </strong>We identified all patients who underwent MT using the Vecta 46 for first-line thromboaspiration for primary or secondary DMVOs. We collected baseline clinical data, angiographic and clinical outcomes, as well as procedural complications. The primary outcome in question was the rate of successful recanalization, which was defined as a modified Thrombolysis in Cerebral Infarction score of ≥2b.</p><p><strong>Results: </strong>We identified 43 patients who underwent MT using the Vecta 46 catheter for thromboaspiration of 54 DMVOs. Intervened vessels included the M2 (23/54), M3 (19/54), and M4 (6/54) branches of the middle cerebral artery, A2 (1/54), A3 (1/54), and A4 (1/54) branches of the anterior cerebral artery, and P1 (1/54), P2 (1/54), and P4 (1/54) branches of the posterior cerebral artery. The median number of passes for primary DMVOs was 2 (IQR: 1-3) and 1 (IQR: 1-1.25) for secondary DMVOs. The rate of successful recanalization was 100% (18/18) for primary DMVOs and 80.6% (29/36) for secondary DMVOs. First-pass effect (FPE) was noted in 55.6% (30/54) of all primary and secondary DMVO cases. Improved short-term clinical outcomes were observed in both the primary (National Institute of Health Stroke Scale [NIHSS] shift: -5 [IQR: -14.25 to -0.25]) and secondary (NIHSS shift: -5 [IQR: -10 to -2]) DMVO groups. A total of six patients died during their hospitalization, though none were deemed procedural-related.</p><p><strong>Conclusions: </strong>Our study demonstrates the safety and efficacy of the Vecta 46 intermediate catheter for thromboaspiration of both primary and secondary DMVOs, achieving high rates of successful recanalization and FPE.</p>","PeriodicalId":14380,"journal":{"name":"Interventional Neuroradiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11559915/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Vecta 46 intermediate catheter for mechanical thrombectomy of distal medium vessel occlusions: A single-center experience.\",\"authors\":\"Joo Won Choi, Yang Qiao, Tej I Mehta, Thomas M Clausen, Y Jonathan Zhang, Samuel Tsappidi, Ferdinand K Hui\",\"doi\":\"10.1177/15910199241283513\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>With emerging evidence supporting the clinical efficacy and safety of mechanical thrombectomy (MT) for distal medium vessel occlusions (DMVOs), MT devices specifically designed to navigate through smaller caliber and more delicate tortuous distal cerebrovasculature are required. This study describes our single-center experience using the AXS Vecta 46 intermediate catheter for first-line thromboaspiration of DMVOs.</p><p><strong>Methods: </strong>We identified all patients who underwent MT using the Vecta 46 for first-line thromboaspiration for primary or secondary DMVOs. We collected baseline clinical data, angiographic and clinical outcomes, as well as procedural complications. The primary outcome in question was the rate of successful recanalization, which was defined as a modified Thrombolysis in Cerebral Infarction score of ≥2b.</p><p><strong>Results: </strong>We identified 43 patients who underwent MT using the Vecta 46 catheter for thromboaspiration of 54 DMVOs. Intervened vessels included the M2 (23/54), M3 (19/54), and M4 (6/54) branches of the middle cerebral artery, A2 (1/54), A3 (1/54), and A4 (1/54) branches of the anterior cerebral artery, and P1 (1/54), P2 (1/54), and P4 (1/54) branches of the posterior cerebral artery. The median number of passes for primary DMVOs was 2 (IQR: 1-3) and 1 (IQR: 1-1.25) for secondary DMVOs. The rate of successful recanalization was 100% (18/18) for primary DMVOs and 80.6% (29/36) for secondary DMVOs. First-pass effect (FPE) was noted in 55.6% (30/54) of all primary and secondary DMVO cases. Improved short-term clinical outcomes were observed in both the primary (National Institute of Health Stroke Scale [NIHSS] shift: -5 [IQR: -14.25 to -0.25]) and secondary (NIHSS shift: -5 [IQR: -10 to -2]) DMVO groups. A total of six patients died during their hospitalization, though none were deemed procedural-related.</p><p><strong>Conclusions: </strong>Our study demonstrates the safety and efficacy of the Vecta 46 intermediate catheter for thromboaspiration of both primary and secondary DMVOs, achieving high rates of successful recanalization and FPE.</p>\",\"PeriodicalId\":14380,\"journal\":{\"name\":\"Interventional Neuroradiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11559915/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Neuroradiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15910199241283513\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199241283513","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
The Vecta 46 intermediate catheter for mechanical thrombectomy of distal medium vessel occlusions: A single-center experience.
Introduction: With emerging evidence supporting the clinical efficacy and safety of mechanical thrombectomy (MT) for distal medium vessel occlusions (DMVOs), MT devices specifically designed to navigate through smaller caliber and more delicate tortuous distal cerebrovasculature are required. This study describes our single-center experience using the AXS Vecta 46 intermediate catheter for first-line thromboaspiration of DMVOs.
Methods: We identified all patients who underwent MT using the Vecta 46 for first-line thromboaspiration for primary or secondary DMVOs. We collected baseline clinical data, angiographic and clinical outcomes, as well as procedural complications. The primary outcome in question was the rate of successful recanalization, which was defined as a modified Thrombolysis in Cerebral Infarction score of ≥2b.
Results: We identified 43 patients who underwent MT using the Vecta 46 catheter for thromboaspiration of 54 DMVOs. Intervened vessels included the M2 (23/54), M3 (19/54), and M4 (6/54) branches of the middle cerebral artery, A2 (1/54), A3 (1/54), and A4 (1/54) branches of the anterior cerebral artery, and P1 (1/54), P2 (1/54), and P4 (1/54) branches of the posterior cerebral artery. The median number of passes for primary DMVOs was 2 (IQR: 1-3) and 1 (IQR: 1-1.25) for secondary DMVOs. The rate of successful recanalization was 100% (18/18) for primary DMVOs and 80.6% (29/36) for secondary DMVOs. First-pass effect (FPE) was noted in 55.6% (30/54) of all primary and secondary DMVO cases. Improved short-term clinical outcomes were observed in both the primary (National Institute of Health Stroke Scale [NIHSS] shift: -5 [IQR: -14.25 to -0.25]) and secondary (NIHSS shift: -5 [IQR: -10 to -2]) DMVO groups. A total of six patients died during their hospitalization, though none were deemed procedural-related.
Conclusions: Our study demonstrates the safety and efficacy of the Vecta 46 intermediate catheter for thromboaspiration of both primary and secondary DMVOs, achieving high rates of successful recanalization and FPE.
期刊介绍:
Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...