离体人类晶状体平均折射率的年龄依赖性。

IF 2.9 2区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Biomedical optics express Pub Date : 2024-09-17 eCollection Date: 2024-10-01 DOI:10.1364/BOE.536501
Ramya Natarajan, Bianca Maceo Heilman, Marco Ruggeri, Arthur Ho, Vivek M Singh, Robert Augusteyn, Jean-Marie Parel, Pravin K Vaddavalli, Fabrice Manns
{"title":"离体人类晶状体平均折射率的年龄依赖性。","authors":"Ramya Natarajan, Bianca Maceo Heilman, Marco Ruggeri, Arthur Ho, Vivek M Singh, Robert Augusteyn, Jean-Marie Parel, Pravin K Vaddavalli, Fabrice Manns","doi":"10.1364/BOE.536501","DOIUrl":null,"url":null,"abstract":"<p><p>We measured the average group refractive index (RI) of 120 isolated lenses from 120 human donors (age: 0.03 to 61 years). The average group RI was calculated from a measurement of the optical thickness of the lens using optical coherence tomography and the apparent window shift of the test chamber caused by the lens. The estimated measurement uncertainty was ±0.004. The group RI at 880 nm was converted to phase RI at 589 nm using the dispersion equation of water and protein. From 2 to 61 years, the mean value of the RI was 1.415 ± 0.002 (group index at 880 nm) and 1.406 ± 0.002 (phase index at 589 nm) independent of age (p = 0.774). Two lenses from donors of age 0.33 and 3 months had significantly lower RI (group index: 1.405 and 1.403; phase index: 1.396 and 1.394). From age 2 to 61, the average lens RI is constant with age within the measurement uncertainty (±0.004).</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"15 10","pages":"5901-5911"},"PeriodicalIF":2.9000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11482174/pdf/","citationCount":"0","resultStr":"{\"title\":\"Age dependence of the average refractive index of the isolated human crystalline lens.\",\"authors\":\"Ramya Natarajan, Bianca Maceo Heilman, Marco Ruggeri, Arthur Ho, Vivek M Singh, Robert Augusteyn, Jean-Marie Parel, Pravin K Vaddavalli, Fabrice Manns\",\"doi\":\"10.1364/BOE.536501\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We measured the average group refractive index (RI) of 120 isolated lenses from 120 human donors (age: 0.03 to 61 years). The average group RI was calculated from a measurement of the optical thickness of the lens using optical coherence tomography and the apparent window shift of the test chamber caused by the lens. The estimated measurement uncertainty was ±0.004. The group RI at 880 nm was converted to phase RI at 589 nm using the dispersion equation of water and protein. From 2 to 61 years, the mean value of the RI was 1.415 ± 0.002 (group index at 880 nm) and 1.406 ± 0.002 (phase index at 589 nm) independent of age (p = 0.774). Two lenses from donors of age 0.33 and 3 months had significantly lower RI (group index: 1.405 and 1.403; phase index: 1.396 and 1.394). From age 2 to 61, the average lens RI is constant with age within the measurement uncertainty (±0.004).</p>\",\"PeriodicalId\":8969,\"journal\":{\"name\":\"Biomedical optics express\",\"volume\":\"15 10\",\"pages\":\"5901-5911\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11482174/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical optics express\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1364/BOE.536501\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.536501","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

我们测量了来自 120 名人体捐献者(年龄:0.03 至 61 岁)的 120 个离体晶状体的平均组折射率 (RI)。通过光学相干断层扫描测量镜片的光学厚度以及镜片引起的测试室视窗偏移,计算出平均组别 RI。估计测量不确定性为 ±0.004。利用水和蛋白质的色散方程,将 880 纳米波长的组 RI 转换为 589 纳米波长的相 RI。从 2 岁到 61 岁,RI 的平均值为 1.415 ± 0.002(880 纳米波长的组指数)和 1.406 ± 0.002(589 纳米波长的相指数),与年龄无关(p = 0.774)。年龄分别为 0.33 个月和 3 个月的两个供体的镜片的 RI 明显较低(组指数:1.405 和 1.403;相指数:1.396 和 1.394)。从 2 岁到 61 岁,镜片平均 RI 随年龄的变化而变化,测量误差在 ±0.004 范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Age dependence of the average refractive index of the isolated human crystalline lens.

We measured the average group refractive index (RI) of 120 isolated lenses from 120 human donors (age: 0.03 to 61 years). The average group RI was calculated from a measurement of the optical thickness of the lens using optical coherence tomography and the apparent window shift of the test chamber caused by the lens. The estimated measurement uncertainty was ±0.004. The group RI at 880 nm was converted to phase RI at 589 nm using the dispersion equation of water and protein. From 2 to 61 years, the mean value of the RI was 1.415 ± 0.002 (group index at 880 nm) and 1.406 ± 0.002 (phase index at 589 nm) independent of age (p = 0.774). Two lenses from donors of age 0.33 and 3 months had significantly lower RI (group index: 1.405 and 1.403; phase index: 1.396 and 1.394). From age 2 to 61, the average lens RI is constant with age within the measurement uncertainty (±0.004).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical optics express
Biomedical optics express BIOCHEMICAL RESEARCH METHODS-OPTICS
CiteScore
6.80
自引率
11.80%
发文量
633
审稿时长
1 months
期刊介绍: The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including: Tissue optics and spectroscopy Novel microscopies Optical coherence tomography Diffuse and fluorescence tomography Photoacoustic and multimodal imaging Molecular imaging and therapies Nanophotonic biosensing Optical biophysics/photobiology Microfluidic optical devices Vision research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信