结合石英晶体微天平和电化学阻抗光谱法,通过在镀有纳菲昂的金电极上进行剥离伏安法测定蒸馏水中的银离子。

IF 5.6 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Talanta Pub Date : 2025-01-01 Epub Date: 2024-10-09 DOI:10.1016/j.talanta.2024.127006
Tingting Han, Sini Chen, Songlin Yang, Tao Song, Xuliang Lin, Qin Yu, Dongxue Han, Johan Bobacka, Li Niu
{"title":"结合石英晶体微天平和电化学阻抗光谱法,通过在镀有纳菲昂的金电极上进行剥离伏安法测定蒸馏水中的银离子。","authors":"Tingting Han, Sini Chen, Songlin Yang, Tao Song, Xuliang Lin, Qin Yu, Dongxue Han, Johan Bobacka, Li Niu","doi":"10.1016/j.talanta.2024.127006","DOIUrl":null,"url":null,"abstract":"<p><p>Here, we propose a stripping voltammetric method for Ag<sup>+</sup> ion determination in distilled water utilizing screen-printed Au electrodes coated with Nafion (Nafion/Au screen-printed electrodes). The concentration of Ag<sup>+</sup> in pure water was determined by linear sweep voltammetry (LSV) after silver deposition on the Nafion/Au electrode. The anodic stripping peak current increased linearly with the concentration of Ag<sup>+</sup> ion in the range from 1 ppm to 22 ppm. The LSV oxidative peak current was increased by extending the silver deposition time from 300 s to 500 s. Repetitive LSV measurements revealed satisfactory reproducibility of the Nafion/Au screen-printed electrodes. The detection mechanism was elucidated by recording mass changes of the Nafion/Au electrode with a quartz crystal microbalance (QCM), and by determining changes in the low-frequency capacitance of the Nafion/Au electrode by electrochemical impedance spectroscopy (EIS). The observed changes in mass and capacitance confirmed Ag<sup>+</sup> accumulation and release processes at the Nafion/Au electrodes, in good agreement with stripping voltammetry. The combination of stripping voltammetry, QCM and EIS allowed a detailed characterization of the ion transfer, deposition and stripping processes at the Nafion/Au electrodes in presence of Ag<sup>+</sup> ions. The Nafion/Au screen-printed electrode enabled voltammetric determination of low Ag<sup>+</sup> concentrations in distilled water, without any sample pretreatment nor addition of supporting electrolyte.</p>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"282 ","pages":"127006"},"PeriodicalIF":5.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of silver ions in distilled water by stripping voltammetry at a Nafion-coated gold electrode in combination with quartz crystal microbalance and electrochemical impedance spectroscopy.\",\"authors\":\"Tingting Han, Sini Chen, Songlin Yang, Tao Song, Xuliang Lin, Qin Yu, Dongxue Han, Johan Bobacka, Li Niu\",\"doi\":\"10.1016/j.talanta.2024.127006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Here, we propose a stripping voltammetric method for Ag<sup>+</sup> ion determination in distilled water utilizing screen-printed Au electrodes coated with Nafion (Nafion/Au screen-printed electrodes). The concentration of Ag<sup>+</sup> in pure water was determined by linear sweep voltammetry (LSV) after silver deposition on the Nafion/Au electrode. The anodic stripping peak current increased linearly with the concentration of Ag<sup>+</sup> ion in the range from 1 ppm to 22 ppm. The LSV oxidative peak current was increased by extending the silver deposition time from 300 s to 500 s. Repetitive LSV measurements revealed satisfactory reproducibility of the Nafion/Au screen-printed electrodes. The detection mechanism was elucidated by recording mass changes of the Nafion/Au electrode with a quartz crystal microbalance (QCM), and by determining changes in the low-frequency capacitance of the Nafion/Au electrode by electrochemical impedance spectroscopy (EIS). The observed changes in mass and capacitance confirmed Ag<sup>+</sup> accumulation and release processes at the Nafion/Au electrodes, in good agreement with stripping voltammetry. The combination of stripping voltammetry, QCM and EIS allowed a detailed characterization of the ion transfer, deposition and stripping processes at the Nafion/Au electrodes in presence of Ag<sup>+</sup> ions. The Nafion/Au screen-printed electrode enabled voltammetric determination of low Ag<sup>+</sup> concentrations in distilled water, without any sample pretreatment nor addition of supporting electrolyte.</p>\",\"PeriodicalId\":435,\"journal\":{\"name\":\"Talanta\",\"volume\":\"282 \",\"pages\":\"127006\"},\"PeriodicalIF\":5.6000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1016/j.talanta.2024.127006\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.talanta.2024.127006","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

在此,我们提出了一种利用涂有 Nafion 的丝网印刷金电极(Nafion/Au 丝网印刷电极)测定蒸馏水中 Ag+ 离子的剥离伏安法。在 Nafion/Au 电极上沉积银后,采用线性扫描伏安法(LSV)测定纯水中的 Ag+ 浓度。在 1 ppm 至 22 ppm 的范围内,阳极剥离峰电流随 Ag+ 离子浓度的增加而线性增加。通过将银沉积时间从 300 秒延长到 500 秒,LSV 氧化峰电流也随之增加。重复 LSV 测量显示,Nafion/Au 丝网印刷电极的再现性令人满意。通过石英晶体微天平 (QCM) 记录 Nafion/Au 电极的质量变化,以及通过电化学阻抗光谱 (EIS) 确定 Nafion/Au 电极的低频电容变化,阐明了检测机制。观察到的质量和电容变化证实了 Ag+ 在 Nafion/Au 电极上的积累和释放过程,这与剥离伏安法十分吻合。结合剥离伏安法、QCM 和 EIS,可以详细描述 Ag+ 离子存在时 Nafion/Au 电极的离子转移、沉积和剥离过程。Nafion/Au 丝网印刷电极可对蒸馏水中的低浓度 Ag+ 进行伏安测定,无需对样品进行任何预处理,也无需添加支撑电解质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of silver ions in distilled water by stripping voltammetry at a Nafion-coated gold electrode in combination with quartz crystal microbalance and electrochemical impedance spectroscopy.

Here, we propose a stripping voltammetric method for Ag+ ion determination in distilled water utilizing screen-printed Au electrodes coated with Nafion (Nafion/Au screen-printed electrodes). The concentration of Ag+ in pure water was determined by linear sweep voltammetry (LSV) after silver deposition on the Nafion/Au electrode. The anodic stripping peak current increased linearly with the concentration of Ag+ ion in the range from 1 ppm to 22 ppm. The LSV oxidative peak current was increased by extending the silver deposition time from 300 s to 500 s. Repetitive LSV measurements revealed satisfactory reproducibility of the Nafion/Au screen-printed electrodes. The detection mechanism was elucidated by recording mass changes of the Nafion/Au electrode with a quartz crystal microbalance (QCM), and by determining changes in the low-frequency capacitance of the Nafion/Au electrode by electrochemical impedance spectroscopy (EIS). The observed changes in mass and capacitance confirmed Ag+ accumulation and release processes at the Nafion/Au electrodes, in good agreement with stripping voltammetry. The combination of stripping voltammetry, QCM and EIS allowed a detailed characterization of the ion transfer, deposition and stripping processes at the Nafion/Au electrodes in presence of Ag+ ions. The Nafion/Au screen-printed electrode enabled voltammetric determination of low Ag+ concentrations in distilled water, without any sample pretreatment nor addition of supporting electrolyte.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Talanta
Talanta 化学-分析化学
CiteScore
12.30
自引率
4.90%
发文量
861
审稿时长
29 days
期刊介绍: Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome. Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信