一种基于卟啉的镍共价有机框架修饰电极,用于电化学检测对乙酰氨基酚。

IF 2.7 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Lu Hou, Yue Jiang, Li-Zhen Chen, Sheng-Feng Zhang, Heng-Ye Li, Mei-Jie Wei, Fen-Ying Kong, Wei Wang
{"title":"一种基于卟啉的镍共价有机框架修饰电极,用于电化学检测对乙酰氨基酚。","authors":"Lu Hou, Yue Jiang, Li-Zhen Chen, Sheng-Feng Zhang, Heng-Ye Li, Mei-Jie Wei, Fen-Ying Kong, Wei Wang","doi":"10.1039/d4ay01447b","DOIUrl":null,"url":null,"abstract":"<p><p>Covalent organic frameworks (COFs) can be rationally designed with functional organic ligands to improve the electrochemical responsiveness of the electrode toward certain medicinal compounds. In this study, we synthesized a COF-Ni electrocatalyst material, which is formed by covalent coupling of electron-rich 2,3,6,7-tetrakis (4-formylphenyl) tetrakis (4-imidazolyl) (TTF-4CHO) and hole-rich 5,10,15,20-tetrakis (4-aminophenyl) porphyrin nickel(II) (TAPP-Ni). The reasonable electron transfer path design, the large specific surface area of the COF and the physical properties of ordered nanopores, as well as the Ni-N<sub>4</sub> bond as a highly active catalytic center, allow the COF-Ni material modified electrode to exhibit excellent sensing performance for acetaminophen (ACOP). The detection limit for ACOP is as low as 47.6 nM, with a linear range of 1-1500 μM, which is better than for most of the reported sensors. With superior interference resistance and good stability performance, COF-Ni is a highly suited electrode modification material for real-world sample detection, which provided a new perspective for application of COF materials in drug analysis.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A nickel porphyrin-based covalent organic framework modified electrode for the electrochemical detection of acetaminophen.\",\"authors\":\"Lu Hou, Yue Jiang, Li-Zhen Chen, Sheng-Feng Zhang, Heng-Ye Li, Mei-Jie Wei, Fen-Ying Kong, Wei Wang\",\"doi\":\"10.1039/d4ay01447b\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Covalent organic frameworks (COFs) can be rationally designed with functional organic ligands to improve the electrochemical responsiveness of the electrode toward certain medicinal compounds. In this study, we synthesized a COF-Ni electrocatalyst material, which is formed by covalent coupling of electron-rich 2,3,6,7-tetrakis (4-formylphenyl) tetrakis (4-imidazolyl) (TTF-4CHO) and hole-rich 5,10,15,20-tetrakis (4-aminophenyl) porphyrin nickel(II) (TAPP-Ni). The reasonable electron transfer path design, the large specific surface area of the COF and the physical properties of ordered nanopores, as well as the Ni-N<sub>4</sub> bond as a highly active catalytic center, allow the COF-Ni material modified electrode to exhibit excellent sensing performance for acetaminophen (ACOP). The detection limit for ACOP is as low as 47.6 nM, with a linear range of 1-1500 μM, which is better than for most of the reported sensors. With superior interference resistance and good stability performance, COF-Ni is a highly suited electrode modification material for real-world sample detection, which provided a new perspective for application of COF materials in drug analysis.</p>\",\"PeriodicalId\":64,\"journal\":{\"name\":\"Analytical Methods\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Methods\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1039/d4ay01447b\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d4ay01447b","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

共价有机框架(COF)可与功能性有机配体进行合理设计,以提高电极对某些药物化合物的电化学响应性。本研究中,我们合成了一种 COF-Ni 电催化剂材料,它是由富含电子的 2,3,6,7-四(4-甲酰基苯基)四(4-咪唑基)(TTF-4CHO)和富含空穴的 5,10,15,20-四(4-氨基苯基)卟啉镍(II)(TAPP-Ni)共价偶联而成。合理的电子传递路径设计、COF 的大比表面积和有序纳米孔的物理性质,以及作为高活性催化中心的 Ni-N4 键,使得 COF-Ni 材料修饰的电极对对乙酰氨基酚(ACOP)具有优异的传感性能。对乙酰氨基酚(ACOP)的检测限低至 47.6 nM,线性范围为 1-1500 μM,优于大多数已报道的传感器。COF-Ni 具有优异的抗干扰性和良好的稳定性,是一种非常适合实际样品检测的电极改性材料,为 COF 材料在药物分析中的应用提供了新的视角。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A nickel porphyrin-based covalent organic framework modified electrode for the electrochemical detection of acetaminophen.

Covalent organic frameworks (COFs) can be rationally designed with functional organic ligands to improve the electrochemical responsiveness of the electrode toward certain medicinal compounds. In this study, we synthesized a COF-Ni electrocatalyst material, which is formed by covalent coupling of electron-rich 2,3,6,7-tetrakis (4-formylphenyl) tetrakis (4-imidazolyl) (TTF-4CHO) and hole-rich 5,10,15,20-tetrakis (4-aminophenyl) porphyrin nickel(II) (TAPP-Ni). The reasonable electron transfer path design, the large specific surface area of the COF and the physical properties of ordered nanopores, as well as the Ni-N4 bond as a highly active catalytic center, allow the COF-Ni material modified electrode to exhibit excellent sensing performance for acetaminophen (ACOP). The detection limit for ACOP is as low as 47.6 nM, with a linear range of 1-1500 μM, which is better than for most of the reported sensors. With superior interference resistance and good stability performance, COF-Ni is a highly suited electrode modification material for real-world sample detection, which provided a new perspective for application of COF materials in drug analysis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信