{"title":"用于热辐射积算仪的 SSDLs 校准方法","authors":"Qian Yang,&nbsp;Shimeng Xu,&nbsp;Jie Fan","doi":"10.1016/j.radphyschem.2024.112299","DOIUrl":null,"url":null,"abstract":"<div><div>The kerma-area product meter (KAP meter) is mainly used for quality assurance in medical imaging research, providing dose quality assessment or dose monitoring for patients. It can be calibrated either in the laboratory or on-site. The purpose of this study is to propose a method for calibrating the KAP meter using a plane-parallel transmission ionization chamber in the SSDLs. In the range of 50 kV–150 kV, under RQR (standard radiation qualities) and RQR additional filtering conditions of the KAP meter, the correction factor <span><math><mrow><msubsup><mi>N</mi><mi>Q</mi><mi>m</mi></msubsup></mrow></math></span> of the transmission ionization chamber is calculated to select two types of KAP meters for the calibration of the transmitted beam. The collimators used to limit the size of the radiation field are respectively 50.07 mm in length, 30.03 mm in length, and 20.05 mm in radius. This method, with uncertainty not exceeding 3.0% while improving calibration efficiency, can replace the unit-specific correction of the laboratory method (Toroi et al., 2008).</div></div>","PeriodicalId":20861,"journal":{"name":"Radiation Physics and Chemistry","volume":"226 ","pages":"Article 112299"},"PeriodicalIF":2.8000,"publicationDate":"2024-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An SSDLs calibration method for the kerma-area product meter\",\"authors\":\"Qian Yang,&nbsp;Shimeng Xu,&nbsp;Jie Fan\",\"doi\":\"10.1016/j.radphyschem.2024.112299\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>The kerma-area product meter (KAP meter) is mainly used for quality assurance in medical imaging research, providing dose quality assessment or dose monitoring for patients. It can be calibrated either in the laboratory or on-site. The purpose of this study is to propose a method for calibrating the KAP meter using a plane-parallel transmission ionization chamber in the SSDLs. In the range of 50 kV–150 kV, under RQR (standard radiation qualities) and RQR additional filtering conditions of the KAP meter, the correction factor <span><math><mrow><msubsup><mi>N</mi><mi>Q</mi><mi>m</mi></msubsup></mrow></math></span> of the transmission ionization chamber is calculated to select two types of KAP meters for the calibration of the transmitted beam. The collimators used to limit the size of the radiation field are respectively 50.07 mm in length, 30.03 mm in length, and 20.05 mm in radius. This method, with uncertainty not exceeding 3.0% while improving calibration efficiency, can replace the unit-specific correction of the laboratory method (Toroi et al., 2008).</div></div>\",\"PeriodicalId\":20861,\"journal\":{\"name\":\"Radiation Physics and Chemistry\",\"volume\":\"226 \",\"pages\":\"Article 112299\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation Physics and Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0969806X24007916\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Physics and Chemistry","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0969806X24007916","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

摘要

KAP 计主要用于医学成像研究的质量保证,为患者提供剂量质量评估或剂量监测。它可以在实验室或现场进行校准。本研究的目的是提出一种在 SSDL 中使用平面平行透射电离室校准 KAP 计的方法。在 50 kV-150 kV 范围内,在 KAP 计的 RQR(标准辐射质量)和 RQR 附加滤波条件下,计算透射电离室的校正系数 NQm,以选择两种类型的 KAP 计对透射光束进行校准。用于限制辐射场大小的准直器长度分别为 50.07 毫米、30.03 毫米和 20.05 毫米。这种方法的不确定性不超过 3.0%,同时提高了校准效率,可以取代实验室方法的特定单位校正(Toroi 等人,2008 年)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An SSDLs calibration method for the kerma-area product meter
The kerma-area product meter (KAP meter) is mainly used for quality assurance in medical imaging research, providing dose quality assessment or dose monitoring for patients. It can be calibrated either in the laboratory or on-site. The purpose of this study is to propose a method for calibrating the KAP meter using a plane-parallel transmission ionization chamber in the SSDLs. In the range of 50 kV–150 kV, under RQR (standard radiation qualities) and RQR additional filtering conditions of the KAP meter, the correction factor NQm of the transmission ionization chamber is calculated to select two types of KAP meters for the calibration of the transmitted beam. The collimators used to limit the size of the radiation field are respectively 50.07 mm in length, 30.03 mm in length, and 20.05 mm in radius. This method, with uncertainty not exceeding 3.0% while improving calibration efficiency, can replace the unit-specific correction of the laboratory method (Toroi et al., 2008).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiation Physics and Chemistry
Radiation Physics and Chemistry 化学-核科学技术
CiteScore
5.60
自引率
17.20%
发文量
574
审稿时长
12 weeks
期刊介绍: Radiation Physics and Chemistry is a multidisciplinary journal that provides a medium for publication of substantial and original papers, reviews, and short communications which focus on research and developments involving ionizing radiation in radiation physics, radiation chemistry and radiation processing. The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria. This could include papers that are very similar to previous publications, only with changed target substrates, employed materials, analyzed sites and experimental methods, report results without presenting new insights and/or hypothesis testing, or do not focus on the radiation effects.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信