腹主动脉瘤血液动力学的个性化数值模拟:模拟结果对输入边界条件的敏感性分析

IF 0.5 4区 工程技术 Q4 ENGINEERING, AEROSPACE
Ya. V. Fedotova, R. Yu. Epifanov, I. I. Volkova, M. S. Maus, N. A. Nikitin, S. A. Aivazov, M. Yu. Khrebtov, A. A. Karpenko, R. I. Mullyadzhanov
{"title":"腹主动脉瘤血液动力学的个性化数值模拟:模拟结果对输入边界条件的敏感性分析","authors":"Ya. V. Fedotova,&nbsp;R. Yu. Epifanov,&nbsp;I. I. Volkova,&nbsp;M. S. Maus,&nbsp;N. A. Nikitin,&nbsp;S. A. Aivazov,&nbsp;M. Yu. Khrebtov,&nbsp;A. A. Karpenko,&nbsp;R. I. Mullyadzhanov","doi":"10.1134/S0869864324020161","DOIUrl":null,"url":null,"abstract":"<div><p>The analysis was performed for input condition sensitivity of hemodynamic simulation performed for a zone of abdominal aortic aneurysm. We took three versions of patient-specific configurations of aneurysm decease and computed the haemodynamics with different spatial and velocity profiles at the aorta inlet. Their impact on hemodynamic characteristics was evaluated. At total, the study was performed for three spatial variants (uniform, parabolic, and parabolic-and-secondary-flow velocity profiles) and three versions of time behavior of velocity profiles: this produces nine cases for every of three chosen geometries. The study demonstrated that one can neglect the impact of the spatial profile for inlet velocity (including the non-coaxial velocity vector components). Meanwhile, the value of reverse diastolic flow is significant for the solution. However, simulation in the zone of abdominal aortic aneurysm does not demonstrate great differences in simulation results for the values of wall shear stress and velocity for the data averaged over a cardiac cycle. For the distribution of the oscillation index of shear, the maximum deviation from the basic solution is about ∼ 10 %, which is quite acceptable for clinical applications.</p></div>","PeriodicalId":800,"journal":{"name":"Thermophysics and Aeromechanics","volume":"31 2","pages":"375 - 391"},"PeriodicalIF":0.5000,"publicationDate":"2024-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Personalized numerical simulation for hemodynamics of abdominal aortic aneurysm: analysis of simulation results sensitivity to the input boundary conditions\",\"authors\":\"Ya. V. Fedotova,&nbsp;R. Yu. Epifanov,&nbsp;I. I. Volkova,&nbsp;M. S. Maus,&nbsp;N. A. Nikitin,&nbsp;S. A. Aivazov,&nbsp;M. Yu. Khrebtov,&nbsp;A. A. Karpenko,&nbsp;R. I. Mullyadzhanov\",\"doi\":\"10.1134/S0869864324020161\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The analysis was performed for input condition sensitivity of hemodynamic simulation performed for a zone of abdominal aortic aneurysm. We took three versions of patient-specific configurations of aneurysm decease and computed the haemodynamics with different spatial and velocity profiles at the aorta inlet. Their impact on hemodynamic characteristics was evaluated. At total, the study was performed for three spatial variants (uniform, parabolic, and parabolic-and-secondary-flow velocity profiles) and three versions of time behavior of velocity profiles: this produces nine cases for every of three chosen geometries. The study demonstrated that one can neglect the impact of the spatial profile for inlet velocity (including the non-coaxial velocity vector components). Meanwhile, the value of reverse diastolic flow is significant for the solution. However, simulation in the zone of abdominal aortic aneurysm does not demonstrate great differences in simulation results for the values of wall shear stress and velocity for the data averaged over a cardiac cycle. For the distribution of the oscillation index of shear, the maximum deviation from the basic solution is about ∼ 10 %, which is quite acceptable for clinical applications.</p></div>\",\"PeriodicalId\":800,\"journal\":{\"name\":\"Thermophysics and Aeromechanics\",\"volume\":\"31 2\",\"pages\":\"375 - 391\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2024-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Thermophysics and Aeromechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S0869864324020161\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, AEROSPACE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thermophysics and Aeromechanics","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1134/S0869864324020161","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, AEROSPACE","Score":null,"Total":0}
引用次数: 0

摘要

该分析是针对腹主动脉瘤区血液动力学模拟的输入条件敏感性进行的。我们采用了三种动脉瘤逝世的患者特定配置,并计算了主动脉入口处不同空间和速度剖面的血液动力学。评估了它们对血液动力学特征的影响。研究共针对三种空间变体(均匀、抛物线、抛物线和二次流速度曲线)和三种速度曲线的时间行为进行:这为每种选定的几何形状产生了九种情况。研究表明,可以忽略空间剖面对入口速度的影响(包括非同轴速度矢量分量)。同时,反向舒张流量的值对求解也很重要。然而,在腹主动脉瘤区进行模拟时,一个心动周期平均数据的壁剪应力和速度值的模拟结果差异不大。对于剪切力振荡指数的分布,与基本解的最大偏差约为∼10%,这在临床应用中是完全可以接受的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Personalized numerical simulation for hemodynamics of abdominal aortic aneurysm: analysis of simulation results sensitivity to the input boundary conditions

The analysis was performed for input condition sensitivity of hemodynamic simulation performed for a zone of abdominal aortic aneurysm. We took three versions of patient-specific configurations of aneurysm decease and computed the haemodynamics with different spatial and velocity profiles at the aorta inlet. Their impact on hemodynamic characteristics was evaluated. At total, the study was performed for three spatial variants (uniform, parabolic, and parabolic-and-secondary-flow velocity profiles) and three versions of time behavior of velocity profiles: this produces nine cases for every of three chosen geometries. The study demonstrated that one can neglect the impact of the spatial profile for inlet velocity (including the non-coaxial velocity vector components). Meanwhile, the value of reverse diastolic flow is significant for the solution. However, simulation in the zone of abdominal aortic aneurysm does not demonstrate great differences in simulation results for the values of wall shear stress and velocity for the data averaged over a cardiac cycle. For the distribution of the oscillation index of shear, the maximum deviation from the basic solution is about ∼ 10 %, which is quite acceptable for clinical applications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Thermophysics and Aeromechanics
Thermophysics and Aeromechanics THERMODYNAMICS-MECHANICS
CiteScore
0.90
自引率
40.00%
发文量
29
审稿时长
>12 weeks
期刊介绍: The journal Thermophysics and Aeromechanics publishes original reports, reviews, and discussions on the following topics: hydrogasdynamics, heat and mass transfer, turbulence, means and methods of aero- and thermophysical experiment, physics of low-temperature plasma, and physical and technical problems of energetics. These topics are the prior fields of investigation at the Institute of Thermophysics and the Institute of Theoretical and Applied Mechanics of the Siberian Branch of the Russian Academy of Sciences (SB RAS), which are the founders of the journal along with SB RAS. This publication promotes an exchange of information between the researchers of Russia and the international scientific community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信