通过牺牲芯鞘电纺丝技术制造临床相关尺寸的管状毛细管仿制品

IF 1.9 Q3 ENGINEERING, MANUFACTURING
Yan Chen, Yingge Zhou
{"title":"通过牺牲芯鞘电纺丝技术制造临床相关尺寸的管状毛细管仿制品","authors":"Yan Chen,&nbsp;Yingge Zhou","doi":"10.1016/j.mfglet.2024.09.056","DOIUrl":null,"url":null,"abstract":"<div><div>Electrospinning is a versatile technique that is often used to fabricate ultra-fine fibers. With the help of a coaxial spinneret, microtubes can be fabricated as potential biomimetic capillary vessels. However, the sizes of electrospun microtubes in recent research were around 5 μm which is smaller to native capillary vessels (5–10 μm). The electrospun microtube diameter can be determined by various electrospinning parameters such as spinning materials, solvent, spinning distance, solution pump rate, applied voltage, etc. In this research, we explored the effects of spinning distance and core/sheath pump rate ratio on microtube diameter and wall thickness. Viscosity, wettability, and tensile tests were also conducted for microtube characterization. The results indicated that the microtube diameters range from 5 μm to 12 μm, which provides a promising direction for the fabrication of biomimetic capillary vessels.</div></div>","PeriodicalId":38186,"journal":{"name":"Manufacturing Letters","volume":"41 ","pages":"Pages 462-468"},"PeriodicalIF":1.9000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical-relevant sized tubular capillary mimicries by sacrificial core-sheath electrospinning\",\"authors\":\"Yan Chen,&nbsp;Yingge Zhou\",\"doi\":\"10.1016/j.mfglet.2024.09.056\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Electrospinning is a versatile technique that is often used to fabricate ultra-fine fibers. With the help of a coaxial spinneret, microtubes can be fabricated as potential biomimetic capillary vessels. However, the sizes of electrospun microtubes in recent research were around 5 μm which is smaller to native capillary vessels (5–10 μm). The electrospun microtube diameter can be determined by various electrospinning parameters such as spinning materials, solvent, spinning distance, solution pump rate, applied voltage, etc. In this research, we explored the effects of spinning distance and core/sheath pump rate ratio on microtube diameter and wall thickness. Viscosity, wettability, and tensile tests were also conducted for microtube characterization. The results indicated that the microtube diameters range from 5 μm to 12 μm, which provides a promising direction for the fabrication of biomimetic capillary vessels.</div></div>\",\"PeriodicalId\":38186,\"journal\":{\"name\":\"Manufacturing Letters\",\"volume\":\"41 \",\"pages\":\"Pages 462-468\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Manufacturing Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2213846324001184\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MANUFACTURING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Manufacturing Letters","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2213846324001184","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MANUFACTURING","Score":null,"Total":0}
引用次数: 0

摘要

电纺丝是一种多功能技术,通常用于制造超细纤维。在同轴喷丝板的帮助下,微管可被制造成潜在的仿生物毛细血管。不过,近期研究中电纺微管的尺寸约为 5 μm,小于原生毛细血管(5-10 μm)。电纺微管的直径可由各种电纺参数决定,如纺丝材料、溶剂、纺丝距离、溶液泵速、施加电压等。本研究探讨了纺丝距离和芯/鞘泵率比对微管直径和壁厚的影响。此外,还进行了粘度、润湿性和拉伸测试,以确定微管的特性。结果表明,微管直径在 5 μm 至 12 μm 之间,这为制造仿生物毛细管容器提供了一个很好的方向。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Clinical-relevant sized tubular capillary mimicries by sacrificial core-sheath electrospinning
Electrospinning is a versatile technique that is often used to fabricate ultra-fine fibers. With the help of a coaxial spinneret, microtubes can be fabricated as potential biomimetic capillary vessels. However, the sizes of electrospun microtubes in recent research were around 5 μm which is smaller to native capillary vessels (5–10 μm). The electrospun microtube diameter can be determined by various electrospinning parameters such as spinning materials, solvent, spinning distance, solution pump rate, applied voltage, etc. In this research, we explored the effects of spinning distance and core/sheath pump rate ratio on microtube diameter and wall thickness. Viscosity, wettability, and tensile tests were also conducted for microtube characterization. The results indicated that the microtube diameters range from 5 μm to 12 μm, which provides a promising direction for the fabrication of biomimetic capillary vessels.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Manufacturing Letters
Manufacturing Letters Engineering-Industrial and Manufacturing Engineering
CiteScore
4.20
自引率
5.10%
发文量
192
审稿时长
60 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信