利用悬臂增强型光声探测光功率的免校准红外吸收光谱法

IF 7.1 1区 医学 Q1 ENGINEERING, BIOMEDICAL
Jussi Rossi , Markku Vainio
{"title":"利用悬臂增强型光声探测光功率的免校准红外吸收光谱法","authors":"Jussi Rossi ,&nbsp;Markku Vainio","doi":"10.1016/j.pacs.2024.100655","DOIUrl":null,"url":null,"abstract":"<div><div>We report on sensitive tunable laser absorption spectroscopy using a multipass gas cell and a solid-state photoacoustic optical power detector. Unlike photoacoustic spectroscopy (PAS), this method readily allows a low gas pressure for high spectral selectivity and a free gas flow for continuous measurements. Our photoacoustic optical power detector has a large linear dynamic range and can be used at almost any optical wavelength, including the middle infrared and THz regions that are challenging to cover with traditional optical detectors. Furthermore, our approach allows for compensation of laser power drifts with a single detector. As a proof of concept, we have measured very weak CO<sub>2</sub> absorption lines at 9.2 µm wavelength and achieved a normalized noise equivalent absorption (NNEA) of 2.35·10<sup>−9</sup> Wcm<sup>−1</sup>Hz<sup>−1/2</sup> with a low-power quantum cascade laser. The absolute value of the gas absorption coefficient is obtained directly from the Beer-Lambert law, making the technique calibration-free.</div></div>","PeriodicalId":56025,"journal":{"name":"Photoacoustics","volume":"40 ","pages":"Article 100655"},"PeriodicalIF":7.1000,"publicationDate":"2024-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Calibration-free infrared absorption spectroscopy using cantilever-enhanced photoacoustic detection of the optical power\",\"authors\":\"Jussi Rossi ,&nbsp;Markku Vainio\",\"doi\":\"10.1016/j.pacs.2024.100655\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>We report on sensitive tunable laser absorption spectroscopy using a multipass gas cell and a solid-state photoacoustic optical power detector. Unlike photoacoustic spectroscopy (PAS), this method readily allows a low gas pressure for high spectral selectivity and a free gas flow for continuous measurements. Our photoacoustic optical power detector has a large linear dynamic range and can be used at almost any optical wavelength, including the middle infrared and THz regions that are challenging to cover with traditional optical detectors. Furthermore, our approach allows for compensation of laser power drifts with a single detector. As a proof of concept, we have measured very weak CO<sub>2</sub> absorption lines at 9.2 µm wavelength and achieved a normalized noise equivalent absorption (NNEA) of 2.35·10<sup>−9</sup> Wcm<sup>−1</sup>Hz<sup>−1/2</sup> with a low-power quantum cascade laser. The absolute value of the gas absorption coefficient is obtained directly from the Beer-Lambert law, making the technique calibration-free.</div></div>\",\"PeriodicalId\":56025,\"journal\":{\"name\":\"Photoacoustics\",\"volume\":\"40 \",\"pages\":\"Article 100655\"},\"PeriodicalIF\":7.1000,\"publicationDate\":\"2024-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Photoacoustics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2213597924000727\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photoacoustics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2213597924000727","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

我们报告了使用多通道气体池和固态光声光学功率检测器进行灵敏可调激光吸收光谱分析的情况。与光声光谱法(PAS)不同的是,这种方法可以利用低气体压力实现高光谱选择性,并利用自由气体流实现连续测量。我们的光声光学功率检测器具有较大的线性动态范围,可用于几乎所有光学波长,包括传统光学检测器难以覆盖的中红外和太赫兹区域。此外,我们的方法还允许使用单个探测器对激光功率漂移进行补偿。作为概念验证,我们测量了波长为 9.2 µm 的极弱二氧化碳吸收线,并利用低功率量子级联激光器实现了 2.35-10-9 Wcm-1Hz-1/2 的归一化噪声等效吸收(NNEA)。气体吸收系数的绝对值可直接从比尔-朗伯定律中获得,因此该技术无需校准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Calibration-free infrared absorption spectroscopy using cantilever-enhanced photoacoustic detection of the optical power
We report on sensitive tunable laser absorption spectroscopy using a multipass gas cell and a solid-state photoacoustic optical power detector. Unlike photoacoustic spectroscopy (PAS), this method readily allows a low gas pressure for high spectral selectivity and a free gas flow for continuous measurements. Our photoacoustic optical power detector has a large linear dynamic range and can be used at almost any optical wavelength, including the middle infrared and THz regions that are challenging to cover with traditional optical detectors. Furthermore, our approach allows for compensation of laser power drifts with a single detector. As a proof of concept, we have measured very weak CO2 absorption lines at 9.2 µm wavelength and achieved a normalized noise equivalent absorption (NNEA) of 2.35·10−9 Wcm−1Hz−1/2 with a low-power quantum cascade laser. The absolute value of the gas absorption coefficient is obtained directly from the Beer-Lambert law, making the technique calibration-free.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Photoacoustics
Photoacoustics Physics and Astronomy-Atomic and Molecular Physics, and Optics
CiteScore
11.40
自引率
16.50%
发文量
96
审稿时长
53 days
期刊介绍: The open access Photoacoustics journal (PACS) aims to publish original research and review contributions in the field of photoacoustics-optoacoustics-thermoacoustics. This field utilizes acoustical and ultrasonic phenomena excited by electromagnetic radiation for the detection, visualization, and characterization of various materials and biological tissues, including living organisms. Recent advancements in laser technologies, ultrasound detection approaches, inverse theory, and fast reconstruction algorithms have greatly supported the rapid progress in this field. The unique contrast provided by molecular absorption in photoacoustic-optoacoustic-thermoacoustic methods has allowed for addressing unmet biological and medical needs such as pre-clinical research, clinical imaging of vasculature, tissue and disease physiology, drug efficacy, surgery guidance, and therapy monitoring. Applications of this field encompass a wide range of medical imaging and sensing applications, including cancer, vascular diseases, brain neurophysiology, ophthalmology, and diabetes. Moreover, photoacoustics-optoacoustics-thermoacoustics is a multidisciplinary field, with contributions from chemistry and nanotechnology, where novel materials such as biodegradable nanoparticles, organic dyes, targeted agents, theranostic probes, and genetically expressed markers are being actively developed. These advanced materials have significantly improved the signal-to-noise ratio and tissue contrast in photoacoustic methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信