Tudor Caciora, Dorina Camelia Ilies, Monica Costea, Lucian Blaga, Zharas Berdenov, Alexandru Ilies, Thowayeb H. Hassan, Ana Cornelia Peres, Bahodirhon Safarov, Ioana Josan, Ioan-Cristian Noje, Olivier Dehoorne, Vasile Grama, Stefan Baias
{"title":"罗马尼亚 19 世纪遗产建筑的微气候评估","authors":"Tudor Caciora, Dorina Camelia Ilies, Monica Costea, Lucian Blaga, Zharas Berdenov, Alexandru Ilies, Thowayeb H. Hassan, Ana Cornelia Peres, Bahodirhon Safarov, Ioana Josan, Ioan-Cristian Noje, Olivier Dehoorne, Vasile Grama, Stefan Baias","doi":"10.1155/2024/2989136","DOIUrl":null,"url":null,"abstract":"<p>The quality of the internal microclimate is a very important issue nowadays, considering that people in developed societies spend a good part of their day inside buildings and means of transport. But the poor quality of indoor air has a double effect; on the one hand, it can harm human health, and on the other hand, it can cause the degradation of materials. Thus, the current study considers the potential influence of a number of 20 pollutants on the exhibits, visitors, and employees of a synagogue that is over 140 years old in the Municipality of Oradea (Romania), which today is included in the list of historical monuments and is open to be visited. The monitoring period consisted of 9 months, during which parameters such as temperature, relative humidity, CO concentration, light intensity, concentration of particulate matter, and other pollutants were monitored. All the obtained values were then reported to the international standards in force for each indicator, both regarding the potential for human health and the integrity of the exhibits. The results indicate that the values of most pollutants respect the allowed thresholds, with more or less permitted exceptions. The most problematic are the values of temperature, relative humidity, HCHO, and VOC, which substantially exceed the allowed limits and vary a considerable difference. This can induce additional stress on the exhibits, leading over time to damage and premature aging; in terms of human health, the indoor microclimate can, in rare cases, cause discomfort associated with headaches, dizziness, and irritation, but the potential to cause persistent ailments is quite low. To maintain a clean internal microclimate, preventive conservation through the continuous monitoring of internal parameters as well as the establishment of long-term strategies to stabilize the values of pollutants are necessary actions.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":"2024 1","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2024-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2024/2989136","citationCount":"0","resultStr":"{\"title\":\"Microclimate Assessment in a 19th-Century Heritage Building From Romania\",\"authors\":\"Tudor Caciora, Dorina Camelia Ilies, Monica Costea, Lucian Blaga, Zharas Berdenov, Alexandru Ilies, Thowayeb H. Hassan, Ana Cornelia Peres, Bahodirhon Safarov, Ioana Josan, Ioan-Cristian Noje, Olivier Dehoorne, Vasile Grama, Stefan Baias\",\"doi\":\"10.1155/2024/2989136\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The quality of the internal microclimate is a very important issue nowadays, considering that people in developed societies spend a good part of their day inside buildings and means of transport. But the poor quality of indoor air has a double effect; on the one hand, it can harm human health, and on the other hand, it can cause the degradation of materials. Thus, the current study considers the potential influence of a number of 20 pollutants on the exhibits, visitors, and employees of a synagogue that is over 140 years old in the Municipality of Oradea (Romania), which today is included in the list of historical monuments and is open to be visited. The monitoring period consisted of 9 months, during which parameters such as temperature, relative humidity, CO concentration, light intensity, concentration of particulate matter, and other pollutants were monitored. All the obtained values were then reported to the international standards in force for each indicator, both regarding the potential for human health and the integrity of the exhibits. The results indicate that the values of most pollutants respect the allowed thresholds, with more or less permitted exceptions. The most problematic are the values of temperature, relative humidity, HCHO, and VOC, which substantially exceed the allowed limits and vary a considerable difference. This can induce additional stress on the exhibits, leading over time to damage and premature aging; in terms of human health, the indoor microclimate can, in rare cases, cause discomfort associated with headaches, dizziness, and irritation, but the potential to cause persistent ailments is quite low. To maintain a clean internal microclimate, preventive conservation through the continuous monitoring of internal parameters as well as the establishment of long-term strategies to stabilize the values of pollutants are necessary actions.</p>\",\"PeriodicalId\":13529,\"journal\":{\"name\":\"Indoor air\",\"volume\":\"2024 1\",\"pages\":\"\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2024/2989136\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indoor air\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1155/2024/2989136\",\"RegionNum\":2,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor air","FirstCategoryId":"93","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/2024/2989136","RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Microclimate Assessment in a 19th-Century Heritage Building From Romania
The quality of the internal microclimate is a very important issue nowadays, considering that people in developed societies spend a good part of their day inside buildings and means of transport. But the poor quality of indoor air has a double effect; on the one hand, it can harm human health, and on the other hand, it can cause the degradation of materials. Thus, the current study considers the potential influence of a number of 20 pollutants on the exhibits, visitors, and employees of a synagogue that is over 140 years old in the Municipality of Oradea (Romania), which today is included in the list of historical monuments and is open to be visited. The monitoring period consisted of 9 months, during which parameters such as temperature, relative humidity, CO concentration, light intensity, concentration of particulate matter, and other pollutants were monitored. All the obtained values were then reported to the international standards in force for each indicator, both regarding the potential for human health and the integrity of the exhibits. The results indicate that the values of most pollutants respect the allowed thresholds, with more or less permitted exceptions. The most problematic are the values of temperature, relative humidity, HCHO, and VOC, which substantially exceed the allowed limits and vary a considerable difference. This can induce additional stress on the exhibits, leading over time to damage and premature aging; in terms of human health, the indoor microclimate can, in rare cases, cause discomfort associated with headaches, dizziness, and irritation, but the potential to cause persistent ailments is quite low. To maintain a clean internal microclimate, preventive conservation through the continuous monitoring of internal parameters as well as the establishment of long-term strategies to stabilize the values of pollutants are necessary actions.
期刊介绍:
The quality of the environment within buildings is a topic of major importance for public health.
Indoor Air provides a location for reporting original research results in the broad area defined by the indoor environment of non-industrial buildings. An international journal with multidisciplinary content, Indoor Air publishes papers reflecting the broad categories of interest in this field: health effects; thermal comfort; monitoring and modelling; source characterization; ventilation and other environmental control techniques.
The research results present the basic information to allow designers, building owners, and operators to provide a healthy and comfortable environment for building occupants, as well as giving medical practitioners information on how to deal with illnesses related to the indoor environment.