{"title":"利用介电泳技术高效捕获和浓缩细菌大小微粒的三维微尖电极微流体装置","authors":"Young-Ho Nam ,&nbsp;Seok-Young Lee ,&nbsp;Seung-Ki Lee ,&nbsp;Jong-Ho Kim ,&nbsp;Jae-Hyoung Park","doi":"10.1016/j.sna.2024.115957","DOIUrl":null,"url":null,"abstract":"<div><div>Microfluidics-based systems have gained considerable attention in the lab-on-chip field owing to their ability to separate, concentrate, and analyze microparticles. Concentrating microparticles is crucial for the high-sensitivity measurement of biomarkers in the analysis of cells or bacteria. This study presents a microfluidic chip using dielectrophoresis (DEP) to capture bacterial microparticles. The chip features a vertically arranged microtip electrode and an indium tin oxide (ITO) electrode, enhancing the electric field concentration effect and enabling optical analysis of the collected particles. The device was designed and fabricated using microfabrication techniques that incorporate a patterned array of microtip electrodes on a polydimethylsiloxane (PDMS) substrate. Experimental studies and numerical simulations were conducted to evaluate the device performance. The fabricated device was applied to the concentration of fluorescent beads with various variables such as particle size, frequency, voltage, and flow rate. The experimental results demonstrated the successful trapping and concentration of microparticles using DEP forces. The recovery rates of the 2.29 µm and 4.42 µm PS beads, when introduced at a flow rate of 1 μL/min and subjected to an applied alternating current (AC) voltage of 200 kHz and 10 V<sub>pp</sub> at the microtip electrode, were measured to be 85.50±2.69 % and 91.83±0.63 %, respectively. Additionally, to assess the applicability of the microtip electrode-based DEP device proposed here for bacteria concentration, capture experiments were conducted using <em>Escherichia coli</em>, demonstrating a recovery rate performance of 77.93±7.31 %. These findings highlight the potential of the proposed microfluidic chip for the concentration and measurement of bacteria, such as <em>E. coli</em>.</div></div>","PeriodicalId":4,"journal":{"name":"ACS Applied Energy Materials","volume":null,"pages":null},"PeriodicalIF":5.4000,"publicationDate":"2024-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Microfluidic device with three-dimensional microtip electrodes for efficient capture and concentration of bacteria-sized microparticles using dielectrophoresis\",\"authors\":\"Young-Ho Nam ,&nbsp;Seok-Young Lee ,&nbsp;Seung-Ki Lee ,&nbsp;Jong-Ho Kim ,&nbsp;Jae-Hyoung Park\",\"doi\":\"10.1016/j.sna.2024.115957\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Microfluidics-based systems have gained considerable attention in the lab-on-chip field owing to their ability to separate, concentrate, and analyze microparticles. Concentrating microparticles is crucial for the high-sensitivity measurement of biomarkers in the analysis of cells or bacteria. This study presents a microfluidic chip using dielectrophoresis (DEP) to capture bacterial microparticles. The chip features a vertically arranged microtip electrode and an indium tin oxide (ITO) electrode, enhancing the electric field concentration effect and enabling optical analysis of the collected particles. The device was designed and fabricated using microfabrication techniques that incorporate a patterned array of microtip electrodes on a polydimethylsiloxane (PDMS) substrate. Experimental studies and numerical simulations were conducted to evaluate the device performance. The fabricated device was applied to the concentration of fluorescent beads with various variables such as particle size, frequency, voltage, and flow rate. The experimental results demonstrated the successful trapping and concentration of microparticles using DEP forces. The recovery rates of the 2.29 µm and 4.42 µm PS beads, when introduced at a flow rate of 1 μL/min and subjected to an applied alternating current (AC) voltage of 200 kHz and 10 V<sub>pp</sub> at the microtip electrode, were measured to be 85.50±2.69 % and 91.83±0.63 %, respectively. Additionally, to assess the applicability of the microtip electrode-based DEP device proposed here for bacteria concentration, capture experiments were conducted using <em>Escherichia coli</em>, demonstrating a recovery rate performance of 77.93±7.31 %. These findings highlight the potential of the proposed microfluidic chip for the concentration and measurement of bacteria, such as <em>E. coli</em>.</div></div>\",\"PeriodicalId\":4,\"journal\":{\"name\":\"ACS Applied Energy Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2024-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Energy Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0924424724009518\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Energy Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0924424724009518","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

摘要

基于微流控技术的系统能够分离、浓缩和分析微颗粒,因此在片上实验室领域备受关注。在分析细胞或细菌时,浓缩微颗粒对于高灵敏度测量生物标记物至关重要。本研究介绍了一种利用介电泳(DEP)捕获细菌微颗粒的微流体芯片。该芯片采用垂直排列的微尖电极和氧化铟锡(ITO)电极,增强了电场集聚效应,可对收集到的微粒进行光学分析。该装置的设计和制造采用了微加工技术,在聚二甲基硅氧烷(PDMS)基底上集成了图案化的微尖电极阵列。为评估该装置的性能,进行了实验研究和数值模拟。所制造的装置被应用于荧光珠的浓缩,其中包含各种变量,如粒度、频率、电压和流速。实验结果表明,利用 DEP 力能成功捕获和浓缩微颗粒。当以 1 μL/min 的流速引入 2.29 µm 和 4.42 µm 的 PS 粒子,并在微尖电极上施加 200 kHz 和 10 Vpp 的交流电压时,测得的回收率分别为 85.50±2.69 % 和 91.83±0.63%。此外,为了评估本文提出的基于微尖电极的 DEP 设备在细菌浓缩方面的适用性,还使用大肠杆菌进行了捕获实验,结果表明回收率为 77.93±7.31%。这些发现凸显了所提出的微流控芯片在细菌(如大肠杆菌)浓缩和测量方面的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Microfluidic device with three-dimensional microtip electrodes for efficient capture and concentration of bacteria-sized microparticles using dielectrophoresis
Microfluidics-based systems have gained considerable attention in the lab-on-chip field owing to their ability to separate, concentrate, and analyze microparticles. Concentrating microparticles is crucial for the high-sensitivity measurement of biomarkers in the analysis of cells or bacteria. This study presents a microfluidic chip using dielectrophoresis (DEP) to capture bacterial microparticles. The chip features a vertically arranged microtip electrode and an indium tin oxide (ITO) electrode, enhancing the electric field concentration effect and enabling optical analysis of the collected particles. The device was designed and fabricated using microfabrication techniques that incorporate a patterned array of microtip electrodes on a polydimethylsiloxane (PDMS) substrate. Experimental studies and numerical simulations were conducted to evaluate the device performance. The fabricated device was applied to the concentration of fluorescent beads with various variables such as particle size, frequency, voltage, and flow rate. The experimental results demonstrated the successful trapping and concentration of microparticles using DEP forces. The recovery rates of the 2.29 µm and 4.42 µm PS beads, when introduced at a flow rate of 1 μL/min and subjected to an applied alternating current (AC) voltage of 200 kHz and 10 Vpp at the microtip electrode, were measured to be 85.50±2.69 % and 91.83±0.63 %, respectively. Additionally, to assess the applicability of the microtip electrode-based DEP device proposed here for bacteria concentration, capture experiments were conducted using Escherichia coli, demonstrating a recovery rate performance of 77.93±7.31 %. These findings highlight the potential of the proposed microfluidic chip for the concentration and measurement of bacteria, such as E. coli.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Energy Materials
ACS Applied Energy Materials Materials Science-Materials Chemistry
CiteScore
10.30
自引率
6.20%
发文量
1368
期刊介绍: ACS Applied Energy Materials is an interdisciplinary journal publishing original research covering all aspects of materials, engineering, chemistry, physics and biology relevant to energy conversion and storage. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important energy applications.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信