开发基于 ZnS(Ag):6Li 和硅光电倍增管的线性位置敏感闪烁中子探测器

IF 0.5 Q4 PHYSICS, CONDENSED MATTER
D. N. Trunov, V. N. Marin, R. A. Sadykov, E. V. Altynbaev, T. I. Glushkova
{"title":"开发基于 ZnS(Ag):6Li 和硅光电倍增管的线性位置敏感闪烁中子探测器","authors":"D. N. Trunov,&nbsp;V. N. Marin,&nbsp;R. A. Sadykov,&nbsp;E. V. Altynbaev,&nbsp;T. I. Glushkova","doi":"10.1134/S1027451024700599","DOIUrl":null,"url":null,"abstract":"<p>A linear position-sensitive neutron detector based on two silicon photomultipliers and an organic light guide has been developed. Determination of the coordinate of the neutron hitting the detector comes from analyzing the amplitude of the signal received from two silicon photomultipliers located at the ends of the light guide. The results of measurements using a collimated <sup>252</sup>Cf source and two types of detectors based on silicon photomultipliers from Sensl with a diffusion reflector and from Hamamatsu without and with a diffusion reflector are presented. Signals from silicon photomultipliers are recorded using an analog-to-digital converter. The neutron impact coordinates are analyzed using the amplitude characteristics of the photosignal. For a detector based on silicon photomultiplier from Sensl, there is no obvious dependence of the signal amplitude on the coordinate of the neutron detection event, in contrast to detectors from Hamamatsu. The resolution of the detector coated with a diffusion reflector is about 10 mm, and without the diffusion reflector it is approximately 5 mm.</p>","PeriodicalId":671,"journal":{"name":"Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques","volume":"18 4","pages":"881 - 886"},"PeriodicalIF":0.5000,"publicationDate":"2024-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers\",\"authors\":\"D. N. Trunov,&nbsp;V. N. Marin,&nbsp;R. A. Sadykov,&nbsp;E. V. Altynbaev,&nbsp;T. I. Glushkova\",\"doi\":\"10.1134/S1027451024700599\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A linear position-sensitive neutron detector based on two silicon photomultipliers and an organic light guide has been developed. Determination of the coordinate of the neutron hitting the detector comes from analyzing the amplitude of the signal received from two silicon photomultipliers located at the ends of the light guide. The results of measurements using a collimated <sup>252</sup>Cf source and two types of detectors based on silicon photomultipliers from Sensl with a diffusion reflector and from Hamamatsu without and with a diffusion reflector are presented. Signals from silicon photomultipliers are recorded using an analog-to-digital converter. The neutron impact coordinates are analyzed using the amplitude characteristics of the photosignal. For a detector based on silicon photomultiplier from Sensl, there is no obvious dependence of the signal amplitude on the coordinate of the neutron detection event, in contrast to detectors from Hamamatsu. The resolution of the detector coated with a diffusion reflector is about 10 mm, and without the diffusion reflector it is approximately 5 mm.</p>\",\"PeriodicalId\":671,\"journal\":{\"name\":\"Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques\",\"volume\":\"18 4\",\"pages\":\"881 - 886\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2024-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1027451024700599\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, CONDENSED MATTER\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1134/S1027451024700599","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, CONDENSED MATTER","Score":null,"Total":0}
引用次数: 0

摘要

基于两个硅光电倍增管和一个有机光导的线性位置敏感中子探测器已经研制成功。通过分析位于光导两端的两个硅光电倍增管接收到的信号的振幅,可以确定撞击探测器的中子的坐标。本文介绍了使用准直 252Cf 中子源和两种探测器进行测量的结果,这两种探测器分别基于 Sensl 公司生产的带有扩散反射器的硅光电倍增管和 Hamamatsu 公司生产的不带扩散反射器和带扩散反射器的硅光电倍增管。使用模数转换器记录来自硅光电倍增管的信号。利用光信号的振幅特性分析中子撞击坐标。与 Hamamatsu 公司的探测器相比,Sensl 公司基于硅光电倍增管的探测器的信号振幅与中子探测事件的坐标没有明显的关系。带扩散反射器的探测器的分辨率约为 10 毫米,不带扩散反射器的探测器的分辨率约为 5 毫米。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers

Development of a Linear Position-Sensitive Scintillation Neutron Detector Based on ZnS(Ag):6Li and Silicon Photomultipliers

A linear position-sensitive neutron detector based on two silicon photomultipliers and an organic light guide has been developed. Determination of the coordinate of the neutron hitting the detector comes from analyzing the amplitude of the signal received from two silicon photomultipliers located at the ends of the light guide. The results of measurements using a collimated 252Cf source and two types of detectors based on silicon photomultipliers from Sensl with a diffusion reflector and from Hamamatsu without and with a diffusion reflector are presented. Signals from silicon photomultipliers are recorded using an analog-to-digital converter. The neutron impact coordinates are analyzed using the amplitude characteristics of the photosignal. For a detector based on silicon photomultiplier from Sensl, there is no obvious dependence of the signal amplitude on the coordinate of the neutron detection event, in contrast to detectors from Hamamatsu. The resolution of the detector coated with a diffusion reflector is about 10 mm, and without the diffusion reflector it is approximately 5 mm.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.90
自引率
25.00%
发文量
144
审稿时长
3-8 weeks
期刊介绍: Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques publishes original articles on the topical problems of solid-state physics, materials science, experimental techniques, condensed media, nanostructures, surfaces of thin films, and phase boundaries: geometric and energetical structures of surfaces, the methods of computer simulations; physical and chemical properties and their changes upon radiation and other treatments; the methods of studies of films and surface layers of crystals (XRD, XPS, synchrotron radiation, neutron and electron diffraction, electron microscopic, scanning tunneling microscopic, atomic force microscopic studies, and other methods that provide data on the surfaces and thin films). Articles related to the methods and technics of structure studies are the focus of the journal. The journal accepts manuscripts of regular articles and reviews in English or Russian language from authors of all countries. All manuscripts are peer-reviewed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信