基于分子印迹聚合物的电化学传感器用于检测莫西沙星

IF 1.1 4区 工程技术 Q4 ELECTROCHEMISTRY
Memoona Shakoor, Nauman Sadiq, Muafia Akbar, Muhammad Shafique, Ghulam Mustafa
{"title":"基于分子印迹聚合物的电化学传感器用于检测莫西沙星","authors":"Memoona Shakoor,&nbsp;Nauman Sadiq,&nbsp;Muafia Akbar,&nbsp;Muhammad Shafique,&nbsp;Ghulam Mustafa","doi":"10.1134/S1023193524700320","DOIUrl":null,"url":null,"abstract":"<p>Moxifloxacin evaluation in pharmaceuticals and biological fluids is in high demand. It is important to fabricate a simple, sensitive, selective, miniaturized, and cost-effective chemical sensor to detect moxifloxacin in the environment. In this study, an electrochemical sensor based on molecularly imprinted polymer (MIP) was fabricated for the detection of moxifloxacin in which interdigital electrodes (IDEs) were used as transducers. Thermal free-radical bulk polymerization was used to synthesize MIP, methacrylic acid (MAA) was used as a functional monomer, ethylene glycol dimethacrylate (EGDMA) as a crosslinker, azobisisobutyronitrile (AIBN) as a free radical initiator, and dimethyl sulfoxide (DMSO) as a porogenic solvent in a poly (methacrylic acid) system for efficient recognition. The LCR meter was used to measure various electrical properties such as inductance and resistance. A concentration-dependent linear response was observed by the fabricated sensor having a lower limit of detection of 240 and 63 ppb for series and parallel resistance, respectively. Meanwhile, series and parallel inductance had lower detection limits of 48 and 8 ppb, respectively. Furthermore, in the presence of competing agents such as uric acid, ascorbic acid, and paracetamol, the fabricated sensor showed a selective response for moxifloxacin. The fabricated sensor also showed reversible and reproducible response.</p>","PeriodicalId":760,"journal":{"name":"Russian Journal of Electrochemistry","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrochemical Sensor Based on Molecularly Imprinted Polymer for the Detection of Moxifloxacin\",\"authors\":\"Memoona Shakoor,&nbsp;Nauman Sadiq,&nbsp;Muafia Akbar,&nbsp;Muhammad Shafique,&nbsp;Ghulam Mustafa\",\"doi\":\"10.1134/S1023193524700320\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Moxifloxacin evaluation in pharmaceuticals and biological fluids is in high demand. It is important to fabricate a simple, sensitive, selective, miniaturized, and cost-effective chemical sensor to detect moxifloxacin in the environment. In this study, an electrochemical sensor based on molecularly imprinted polymer (MIP) was fabricated for the detection of moxifloxacin in which interdigital electrodes (IDEs) were used as transducers. Thermal free-radical bulk polymerization was used to synthesize MIP, methacrylic acid (MAA) was used as a functional monomer, ethylene glycol dimethacrylate (EGDMA) as a crosslinker, azobisisobutyronitrile (AIBN) as a free radical initiator, and dimethyl sulfoxide (DMSO) as a porogenic solvent in a poly (methacrylic acid) system for efficient recognition. The LCR meter was used to measure various electrical properties such as inductance and resistance. A concentration-dependent linear response was observed by the fabricated sensor having a lower limit of detection of 240 and 63 ppb for series and parallel resistance, respectively. Meanwhile, series and parallel inductance had lower detection limits of 48 and 8 ppb, respectively. Furthermore, in the presence of competing agents such as uric acid, ascorbic acid, and paracetamol, the fabricated sensor showed a selective response for moxifloxacin. The fabricated sensor also showed reversible and reproducible response.</p>\",\"PeriodicalId\":760,\"journal\":{\"name\":\"Russian Journal of Electrochemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Russian Journal of Electrochemistry\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1134/S1023193524700320\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ELECTROCHEMISTRY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Russian Journal of Electrochemistry","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1134/S1023193524700320","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrochemical Sensor Based on Molecularly Imprinted Polymer for the Detection of Moxifloxacin

Moxifloxacin evaluation in pharmaceuticals and biological fluids is in high demand. It is important to fabricate a simple, sensitive, selective, miniaturized, and cost-effective chemical sensor to detect moxifloxacin in the environment. In this study, an electrochemical sensor based on molecularly imprinted polymer (MIP) was fabricated for the detection of moxifloxacin in which interdigital electrodes (IDEs) were used as transducers. Thermal free-radical bulk polymerization was used to synthesize MIP, methacrylic acid (MAA) was used as a functional monomer, ethylene glycol dimethacrylate (EGDMA) as a crosslinker, azobisisobutyronitrile (AIBN) as a free radical initiator, and dimethyl sulfoxide (DMSO) as a porogenic solvent in a poly (methacrylic acid) system for efficient recognition. The LCR meter was used to measure various electrical properties such as inductance and resistance. A concentration-dependent linear response was observed by the fabricated sensor having a lower limit of detection of 240 and 63 ppb for series and parallel resistance, respectively. Meanwhile, series and parallel inductance had lower detection limits of 48 and 8 ppb, respectively. Furthermore, in the presence of competing agents such as uric acid, ascorbic acid, and paracetamol, the fabricated sensor showed a selective response for moxifloxacin. The fabricated sensor also showed reversible and reproducible response.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Russian Journal of Electrochemistry
Russian Journal of Electrochemistry 工程技术-电化学
CiteScore
1.90
自引率
8.30%
发文量
102
审稿时长
6 months
期刊介绍: Russian Journal of Electrochemistry is a journal that covers all aspects of research in modern electrochemistry. The journal welcomes submissions in English or Russian regardless of country and nationality of authors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信