持久性左心室辅助装置 (LVAD) 植入术后的早期中风:胸外科医师学会 Intermacs 国家数据库分析。

IF 6.4 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Ezequiel J Molina, Daniel Goldstein, Ryan S Cantor, Manreet K Kanwar, Dan Meyer, Ulrich Jorde, Omar Saeed, Katherine Wood, Rama Raju Rudraraju, Seth Lewis, James K Kirklin, Francis D Pagani, Arman Kilic
{"title":"持久性左心室辅助装置 (LVAD) 植入术后的早期中风:胸外科医师学会 Intermacs 国家数据库分析。","authors":"Ezequiel J Molina, Daniel Goldstein, Ryan S Cantor, Manreet K Kanwar, Dan Meyer, Ulrich Jorde, Omar Saeed, Katherine Wood, Rama Raju Rudraraju, Seth Lewis, James K Kirklin, Francis D Pagani, Arman Kilic","doi":"10.1016/j.healun.2024.09.031","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Stroke remains a devastating complication of durable left ventricular assist device (LVAD) therapy. This study evaluated the incidence and risk factors for early stroke within 7 days following LVAD implantation investigating both traditional pre-implant and new intraoperative variables collected by The Society of Thoracic Surgeons (STS) Intermacs National Database.</p><p><strong>Methods: </strong>STS Intermacs was queried for patients undergoing implantation of a fully magnetically levitated centrifugal LVAD between November 25, 2020 and June 30, 2023. STS Intermacs stroke definitions were used to identify patients who suffered a stroke within the first 7 postoperative days (POD). A multivariable logistic regression model was created to generate adjusted odd ratios (OR) for variables associated with early stroke.</p><p><strong>Results: </strong>Among 6,950 patients in the study cohort, 5.9% (413/6950) developed a stroke after a median follow-up of 11 months, with 50% (205/413) of strokes occurring within 7 days after LVAD implantation. Of the strokes occurring during POD 0-7, 70% (144/205) occurred on POD 0-2. By multivariable analysis, the following factors were associated with early stroke: older age (70 vs 50; OR 1.4, p = 0.0129), white race (OR 1.5, p = 0.0078), pre-implant temporary mechanical circulatory support (MCS) bridge (temporary LVAD only: OR 1.6, extracorporeal membrane oxygenation [ECMO] only: OR 1.7, combination of both devices: OR 3.3; p = 0.0001) and presence of an unremoved left atrial clot (OR 8.0, p < 0.0001).</p><p><strong>Conclusions: </strong>A significant proportion of strokes occur within the first 7 days following LVAD implantation, particularly within the first 2 days. In addition to pre-implant variables, we identified modifiable intraoperative factors associated with stroke that provide an opportunity for further risk mitigation and improvement in quality of care.</p>","PeriodicalId":15900,"journal":{"name":"Journal of Heart and Lung Transplantation","volume":" ","pages":""},"PeriodicalIF":6.4000,"publicationDate":"2024-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Early stroke following durable left ventricular assist device (LVAD) implantation: An analysis of the Society of Thoracic Surgeons Intermacs National Database.\",\"authors\":\"Ezequiel J Molina, Daniel Goldstein, Ryan S Cantor, Manreet K Kanwar, Dan Meyer, Ulrich Jorde, Omar Saeed, Katherine Wood, Rama Raju Rudraraju, Seth Lewis, James K Kirklin, Francis D Pagani, Arman Kilic\",\"doi\":\"10.1016/j.healun.2024.09.031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Stroke remains a devastating complication of durable left ventricular assist device (LVAD) therapy. This study evaluated the incidence and risk factors for early stroke within 7 days following LVAD implantation investigating both traditional pre-implant and new intraoperative variables collected by The Society of Thoracic Surgeons (STS) Intermacs National Database.</p><p><strong>Methods: </strong>STS Intermacs was queried for patients undergoing implantation of a fully magnetically levitated centrifugal LVAD between November 25, 2020 and June 30, 2023. STS Intermacs stroke definitions were used to identify patients who suffered a stroke within the first 7 postoperative days (POD). A multivariable logistic regression model was created to generate adjusted odd ratios (OR) for variables associated with early stroke.</p><p><strong>Results: </strong>Among 6,950 patients in the study cohort, 5.9% (413/6950) developed a stroke after a median follow-up of 11 months, with 50% (205/413) of strokes occurring within 7 days after LVAD implantation. Of the strokes occurring during POD 0-7, 70% (144/205) occurred on POD 0-2. By multivariable analysis, the following factors were associated with early stroke: older age (70 vs 50; OR 1.4, p = 0.0129), white race (OR 1.5, p = 0.0078), pre-implant temporary mechanical circulatory support (MCS) bridge (temporary LVAD only: OR 1.6, extracorporeal membrane oxygenation [ECMO] only: OR 1.7, combination of both devices: OR 3.3; p = 0.0001) and presence of an unremoved left atrial clot (OR 8.0, p < 0.0001).</p><p><strong>Conclusions: </strong>A significant proportion of strokes occur within the first 7 days following LVAD implantation, particularly within the first 2 days. In addition to pre-implant variables, we identified modifiable intraoperative factors associated with stroke that provide an opportunity for further risk mitigation and improvement in quality of care.</p>\",\"PeriodicalId\":15900,\"journal\":{\"name\":\"Journal of Heart and Lung Transplantation\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":6.4000,\"publicationDate\":\"2024-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Heart and Lung Transplantation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.healun.2024.09.031\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Heart and Lung Transplantation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.healun.2024.09.031","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:中风仍然是左心室辅助装置(LVAD)持久治疗的一种破坏性并发症。本研究通过胸外科医师学会(STS)Intermacs 国家数据库收集的传统植入前变量和新的术中变量,评估了 LVAD 植入术后 7 天内早期中风的发生率和风险因素:对 2020 年 11 月 25 日至 2023 年 6 月 30 日期间接受全磁悬浮离心式 LVAD 植入术的患者进行了 STS Intermacs 查询。STS Intermacs 中风定义用于识别术后前 7 天 (POD) 内发生中风的患者。建立了一个多变量逻辑回归模型,以生成与早期中风相关变量的调整奇数比 (OR):结果:在研究队列的 6950 名患者中,5.9%(413/6950)的患者在中位随访 11 个月后发生中风,其中 50%(205/413)的中风发生在 LVAD 植入术后 7 天内。在 POD 0-7 期间发生的中风中,70%(144/205)发生在 POD 0-2。通过多变量分析,以下因素与早期中风相关:年龄较大(70 岁对 50 岁;OR 1.4,P=0.0129)、白种人(OR 1.5,P=0.0078)、植入前临时 MCS 桥接(仅临时 LVAD:OR 1.6,仅 ECMO:OR 1.7,两者结合:OR 1.7:OR1.7,两种装置的组合:OR3.3;P=0.0001)以及存在未移除的左心房血栓(OR8.0,PC结论:很大一部分中风发生在植入 LVAD 后的头 7 天内,尤其是头 2 天内。除了植入前的变量外,我们还发现了与中风相关的术中可改变因素,这些因素为进一步降低风险和提高护理质量提供了机会。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Early stroke following durable left ventricular assist device (LVAD) implantation: An analysis of the Society of Thoracic Surgeons Intermacs National Database.

Background: Stroke remains a devastating complication of durable left ventricular assist device (LVAD) therapy. This study evaluated the incidence and risk factors for early stroke within 7 days following LVAD implantation investigating both traditional pre-implant and new intraoperative variables collected by The Society of Thoracic Surgeons (STS) Intermacs National Database.

Methods: STS Intermacs was queried for patients undergoing implantation of a fully magnetically levitated centrifugal LVAD between November 25, 2020 and June 30, 2023. STS Intermacs stroke definitions were used to identify patients who suffered a stroke within the first 7 postoperative days (POD). A multivariable logistic regression model was created to generate adjusted odd ratios (OR) for variables associated with early stroke.

Results: Among 6,950 patients in the study cohort, 5.9% (413/6950) developed a stroke after a median follow-up of 11 months, with 50% (205/413) of strokes occurring within 7 days after LVAD implantation. Of the strokes occurring during POD 0-7, 70% (144/205) occurred on POD 0-2. By multivariable analysis, the following factors were associated with early stroke: older age (70 vs 50; OR 1.4, p = 0.0129), white race (OR 1.5, p = 0.0078), pre-implant temporary mechanical circulatory support (MCS) bridge (temporary LVAD only: OR 1.6, extracorporeal membrane oxygenation [ECMO] only: OR 1.7, combination of both devices: OR 3.3; p = 0.0001) and presence of an unremoved left atrial clot (OR 8.0, p < 0.0001).

Conclusions: A significant proportion of strokes occur within the first 7 days following LVAD implantation, particularly within the first 2 days. In addition to pre-implant variables, we identified modifiable intraoperative factors associated with stroke that provide an opportunity for further risk mitigation and improvement in quality of care.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
10.10
自引率
6.70%
发文量
1667
审稿时长
69 days
期刊介绍: The Journal of Heart and Lung Transplantation, the official publication of the International Society for Heart and Lung Transplantation, brings readers essential scholarly and timely information in the field of cardio-pulmonary transplantation, mechanical and biological support of the failing heart, advanced lung disease (including pulmonary vascular disease) and cell replacement therapy. Importantly, the journal also serves as a medium of communication of pre-clinical sciences in all these rapidly expanding areas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信