{"title":"单侧耳聋患者使用人工耳蜗的情况及其影响因素。","authors":"Vanessa Y J Tan, Rodney Hollow, Sylvia Tari, Alex Rousset, Raoul Wills, Robert J S Briggs, Richard Charles Dowell","doi":"10.1080/14670100.2024.2403224","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The primary objective was to examine duration of daily cochlear implant (CI) usage at 12 and 24 months post-operatively in single sided deafness (SSD). The secondary objective was to examine factors that could affect CI usage.</p><p><strong>Methods: </strong>Retrospective cohort of patients with SSD who received CI from January 2015 to March 2020. CI usage was evaluated at 12 and 24 months. Hearing loss duration, tinnitus scores and signal-to-noise ratio (SNR) were correlated with CI usage at 12 months.</p><p><strong>Results: </strong>Usage data was available for 54 patients at 12 months and 38 patients at 24 months. The mean usage was 8.2 h/day (SD 4.2) at 12 months, 7.0 h/day (SD 5.1) at 24 months. 5 out of 54 (9.3%) and 7 out of 38 patients (18.4%) were non-users at 12 and 24 months post-operatively. An improved mean SNR score from pre-operative 4.4 dB (SD 2.8) to - 0.70 dB (SD 4.2) at 12 months post-operative was positively correlated with CI usage at 12 and 24 months. Hearing loss duration and tinnitus scores were not associated with CI usage.</p><p><strong>Conclusions: </strong>18.4% of our patients were non-users at 24 months. Mean usage at 24 months was 7.0 h/day. Improved hearing in noise at 12 months was correlated with better usage.</p>","PeriodicalId":53553,"journal":{"name":"COCHLEAR IMPLANTS INTERNATIONAL","volume":" ","pages":"387-393"},"PeriodicalIF":1.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cochlear implant usage in single sided deafness and factors affecting usage.\",\"authors\":\"Vanessa Y J Tan, Rodney Hollow, Sylvia Tari, Alex Rousset, Raoul Wills, Robert J S Briggs, Richard Charles Dowell\",\"doi\":\"10.1080/14670100.2024.2403224\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The primary objective was to examine duration of daily cochlear implant (CI) usage at 12 and 24 months post-operatively in single sided deafness (SSD). The secondary objective was to examine factors that could affect CI usage.</p><p><strong>Methods: </strong>Retrospective cohort of patients with SSD who received CI from January 2015 to March 2020. CI usage was evaluated at 12 and 24 months. Hearing loss duration, tinnitus scores and signal-to-noise ratio (SNR) were correlated with CI usage at 12 months.</p><p><strong>Results: </strong>Usage data was available for 54 patients at 12 months and 38 patients at 24 months. The mean usage was 8.2 h/day (SD 4.2) at 12 months, 7.0 h/day (SD 5.1) at 24 months. 5 out of 54 (9.3%) and 7 out of 38 patients (18.4%) were non-users at 12 and 24 months post-operatively. An improved mean SNR score from pre-operative 4.4 dB (SD 2.8) to - 0.70 dB (SD 4.2) at 12 months post-operative was positively correlated with CI usage at 12 and 24 months. Hearing loss duration and tinnitus scores were not associated with CI usage.</p><p><strong>Conclusions: </strong>18.4% of our patients were non-users at 24 months. Mean usage at 24 months was 7.0 h/day. Improved hearing in noise at 12 months was correlated with better usage.</p>\",\"PeriodicalId\":53553,\"journal\":{\"name\":\"COCHLEAR IMPLANTS INTERNATIONAL\",\"volume\":\" \",\"pages\":\"387-393\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"COCHLEAR IMPLANTS INTERNATIONAL\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/14670100.2024.2403224\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OTORHINOLARYNGOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"COCHLEAR IMPLANTS INTERNATIONAL","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14670100.2024.2403224","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/9 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目标:主要目的是研究单侧耳聋(SSD)患者术后 12 个月和 24 个月每天使用人工耳蜗(CI)的持续时间。次要目标是研究可能影响 CI 使用的因素:方法:对 2015 年 1 月至 2020 年 3 月期间接受 CI 治疗的 SSD 患者进行回顾性队列研究。在 12 个月和 24 个月时对 CI 使用情况进行评估。听力损失持续时间、耳鸣评分和信噪比(SNR)与 12 个月时的 CI 使用情况相关:结果:54 名患者获得了 12 个月的使用数据,38 名患者获得了 24 个月的使用数据。12 个月时的平均使用时间为 8.2 小时/天(标清 4.2),24 个月时为 7.0 小时/天(标清 5.1)。术后 12 个月和 24 个月,54 位患者中有 5 位(9.3%)和 38 位患者中有 7 位(18.4%)不使用。术后 12 个月时,信噪比平均值从术前的 4.4 dB (SD 2.8) 降至 - 0.70 dB (SD 4.2),这与术后 12 个月和 24 个月时使用人工耳蜗呈正相关。听力损失持续时间和耳鸣评分与使用人工耳蜗无关:18.4%的患者在24个月时未使用人工耳蜗。24 个月时的平均使用时间为 7.0 小时/天。12 个月时噪音中听力的改善与更好的使用率相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cochlear implant usage in single sided deafness and factors affecting usage.

Objectives: The primary objective was to examine duration of daily cochlear implant (CI) usage at 12 and 24 months post-operatively in single sided deafness (SSD). The secondary objective was to examine factors that could affect CI usage.

Methods: Retrospective cohort of patients with SSD who received CI from January 2015 to March 2020. CI usage was evaluated at 12 and 24 months. Hearing loss duration, tinnitus scores and signal-to-noise ratio (SNR) were correlated with CI usage at 12 months.

Results: Usage data was available for 54 patients at 12 months and 38 patients at 24 months. The mean usage was 8.2 h/day (SD 4.2) at 12 months, 7.0 h/day (SD 5.1) at 24 months. 5 out of 54 (9.3%) and 7 out of 38 patients (18.4%) were non-users at 12 and 24 months post-operatively. An improved mean SNR score from pre-operative 4.4 dB (SD 2.8) to - 0.70 dB (SD 4.2) at 12 months post-operative was positively correlated with CI usage at 12 and 24 months. Hearing loss duration and tinnitus scores were not associated with CI usage.

Conclusions: 18.4% of our patients were non-users at 24 months. Mean usage at 24 months was 7.0 h/day. Improved hearing in noise at 12 months was correlated with better usage.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
COCHLEAR IMPLANTS INTERNATIONAL
COCHLEAR IMPLANTS INTERNATIONAL Medicine-Otorhinolaryngology
CiteScore
3.10
自引率
0.00%
发文量
29
期刊介绍: Cochlear Implants International was founded as an interdisciplinary, peer-reviewed journal in response to the growing number of publications in the field of cochlear implants. It was designed to meet a need to include scientific contributions from all the disciplines that are represented in cochlear implant teams: audiology, medicine and surgery, speech therapy and speech pathology, psychology, hearing therapy, radiology, pathology, engineering and acoustics, teaching, and communication. The aim was to found a truly interdisciplinary journal, representing the full breadth of the field of cochlear implantation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信