Arsalan Farhangee, Edward Davies, Guy Haywood, Katie Gaughan, Ion Mindrila
{"title":"使用 Vascutek 补丁对广泛前心肌梗死和左心室心尖内膜成形术的患者进行经房间隔左心室心内膜导联--病例报告。","authors":"Arsalan Farhangee, Edward Davies, Guy Haywood, Katie Gaughan, Ion Mindrila","doi":"10.21037/acr-23-109","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cardiac resynchronization therapy (CRT) implantation has significantly improved quality of life and reduced overall mortality due to heart failure. The conventional method of CRT implantation is implanting a left ventricle (LV) lead into a side branch of the coronary sinus (CS) tributary to pace the epicardial surface and capture the LV. This is safe, and well tolerated with a high success rate. The rate of failure to place an LV lead has decreased over time, however, there are still challenging cases where a conventional CRT implant fails and alternative techniques are being considered, one such technique is trans-septal endocardial LV lead placement used to capture the LV, endocardially but its use is limited due to lack of evidence, practice uptake and clinical trials.</p><p><strong>Case description: </strong>We present, a case report of a patient for whom we successfully used a trans-septal left ventricle (TSLV) endocardial lead implantation approach following a failed LV lead implant via the CS to get effective cardiac resynchronisation.</p><p><strong>Conclusions: </strong>Post-TSLV lead implantation follow-up checks were normal with good electrical parameters and appropriate biventricular pacing. No post-procedural complications were reported, and echocardiographic parameters improved at follow-up. We believe, although, TSLV lead implant is more complex and often double operators are required, in selected patients, it can be a safe alternative following a failed traditional LV lead implant via the CS.</p>","PeriodicalId":29752,"journal":{"name":"AME Case Reports","volume":"8 ","pages":"106"},"PeriodicalIF":0.7000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11459412/pdf/","citationCount":"0","resultStr":"{\"title\":\"Trans-septal left ventricular endocardial lead in a patient with extensive anterior myocardial infarction and left ventricle (LV) apical endoventriculoplasty using a Vascutek patch-case report.\",\"authors\":\"Arsalan Farhangee, Edward Davies, Guy Haywood, Katie Gaughan, Ion Mindrila\",\"doi\":\"10.21037/acr-23-109\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Cardiac resynchronization therapy (CRT) implantation has significantly improved quality of life and reduced overall mortality due to heart failure. The conventional method of CRT implantation is implanting a left ventricle (LV) lead into a side branch of the coronary sinus (CS) tributary to pace the epicardial surface and capture the LV. This is safe, and well tolerated with a high success rate. The rate of failure to place an LV lead has decreased over time, however, there are still challenging cases where a conventional CRT implant fails and alternative techniques are being considered, one such technique is trans-septal endocardial LV lead placement used to capture the LV, endocardially but its use is limited due to lack of evidence, practice uptake and clinical trials.</p><p><strong>Case description: </strong>We present, a case report of a patient for whom we successfully used a trans-septal left ventricle (TSLV) endocardial lead implantation approach following a failed LV lead implant via the CS to get effective cardiac resynchronisation.</p><p><strong>Conclusions: </strong>Post-TSLV lead implantation follow-up checks were normal with good electrical parameters and appropriate biventricular pacing. No post-procedural complications were reported, and echocardiographic parameters improved at follow-up. We believe, although, TSLV lead implant is more complex and often double operators are required, in selected patients, it can be a safe alternative following a failed traditional LV lead implant via the CS.</p>\",\"PeriodicalId\":29752,\"journal\":{\"name\":\"AME Case Reports\",\"volume\":\"8 \",\"pages\":\"106\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11459412/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AME Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21037/acr-23-109\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AME Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21037/acr-23-109","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
Trans-septal left ventricular endocardial lead in a patient with extensive anterior myocardial infarction and left ventricle (LV) apical endoventriculoplasty using a Vascutek patch-case report.
Background: Cardiac resynchronization therapy (CRT) implantation has significantly improved quality of life and reduced overall mortality due to heart failure. The conventional method of CRT implantation is implanting a left ventricle (LV) lead into a side branch of the coronary sinus (CS) tributary to pace the epicardial surface and capture the LV. This is safe, and well tolerated with a high success rate. The rate of failure to place an LV lead has decreased over time, however, there are still challenging cases where a conventional CRT implant fails and alternative techniques are being considered, one such technique is trans-septal endocardial LV lead placement used to capture the LV, endocardially but its use is limited due to lack of evidence, practice uptake and clinical trials.
Case description: We present, a case report of a patient for whom we successfully used a trans-septal left ventricle (TSLV) endocardial lead implantation approach following a failed LV lead implant via the CS to get effective cardiac resynchronisation.
Conclusions: Post-TSLV lead implantation follow-up checks were normal with good electrical parameters and appropriate biventricular pacing. No post-procedural complications were reported, and echocardiographic parameters improved at follow-up. We believe, although, TSLV lead implant is more complex and often double operators are required, in selected patients, it can be a safe alternative following a failed traditional LV lead implant via the CS.