使用压电锯对下颌骨颊皮层进行截骨术后下牙槽神经潜在损伤的组织学评估。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY
Shamal Hassan Qadir, Khurshid Abubakir Kheder, Snur M A Hassan
{"title":"使用压电锯对下颌骨颊皮层进行截骨术后下牙槽神经潜在损伤的组织学评估。","authors":"Shamal Hassan Qadir, Khurshid Abubakir Kheder, Snur M A Hassan","doi":"10.14715/cmb/2024.70.9.6","DOIUrl":null,"url":null,"abstract":"<p><p>The present study aimed to evaluate the effect of Piezosurgery on histopathologic features of the inferior alveolar nerve (IAN) damage after osteotomy of the buccal cortex of the mandible using piezoelectric devices in Hamdani sheep. A total of ten healthy mature female sheep were included. Each side of the mandible underwent two different experiments: the first experiment operated directly on the mental nerve by touching and activating the piezo tip on the nerve for ten seconds for the left side and thirty seconds for the right side. In the second experiment, the inferior alveolar nerve was touched by an activated piezo tip inside the mandibular canal for ten seconds on the left side and thirty seconds on the right side. All the nerve samples underwent histopathological evaluation, and the scoring system was performed to assess the nerve structures. Mental nerves exposed to piezo tip for 10 seconds showed mild abnormality including disruption of the perineurium with the endoneurium remaining intact. Mental nerves exposed for 30 seconds showed moderate injury with destruction of the perineurium and moderate degeneration of nerve fibers, nevertheless, the endoneurium remained continuous with normal node of Ranvier. Severe damage of the inferior alveolar nerve was seen after exposure to piezo tip for 10 seconds, which showed sloughing of the perineurium and severe vacuolar degeneration of nerve fibers, partial disruption of the endoneurium; however, the axons were still intact. Inferior alveolar nerves exposed for 30 seconds revealed destruction of the perineurium, marked vacuolar degeneration of nerve fibers, focal damage of axon and loss of endoneurium (axonotmesis). Piezosurgery devices have the potential to cause severe nerve damage during surgery and should be used very carefully.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Histological assessment of potential inferior alveolar nerve injury following osteotomy of the mandibular buccal cortex using a piezoelectric saw.\",\"authors\":\"Shamal Hassan Qadir, Khurshid Abubakir Kheder, Snur M A Hassan\",\"doi\":\"10.14715/cmb/2024.70.9.6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The present study aimed to evaluate the effect of Piezosurgery on histopathologic features of the inferior alveolar nerve (IAN) damage after osteotomy of the buccal cortex of the mandible using piezoelectric devices in Hamdani sheep. A total of ten healthy mature female sheep were included. Each side of the mandible underwent two different experiments: the first experiment operated directly on the mental nerve by touching and activating the piezo tip on the nerve for ten seconds for the left side and thirty seconds for the right side. In the second experiment, the inferior alveolar nerve was touched by an activated piezo tip inside the mandibular canal for ten seconds on the left side and thirty seconds on the right side. All the nerve samples underwent histopathological evaluation, and the scoring system was performed to assess the nerve structures. Mental nerves exposed to piezo tip for 10 seconds showed mild abnormality including disruption of the perineurium with the endoneurium remaining intact. Mental nerves exposed for 30 seconds showed moderate injury with destruction of the perineurium and moderate degeneration of nerve fibers, nevertheless, the endoneurium remained continuous with normal node of Ranvier. Severe damage of the inferior alveolar nerve was seen after exposure to piezo tip for 10 seconds, which showed sloughing of the perineurium and severe vacuolar degeneration of nerve fibers, partial disruption of the endoneurium; however, the axons were still intact. Inferior alveolar nerves exposed for 30 seconds revealed destruction of the perineurium, marked vacuolar degeneration of nerve fibers, focal damage of axon and loss of endoneurium (axonotmesis). Piezosurgery devices have the potential to cause severe nerve damage during surgery and should be used very carefully.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.14715/cmb/2024.70.9.6\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.14715/cmb/2024.70.9.6","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在评估压电手术对哈姆达尼绵羊下颌骨颊皮层截骨后下牙槽神经(IAN)损伤组织病理学特征的影响。共纳入 10 只健康成熟的雌性绵羊。下颌骨的两侧分别进行了两次不同的实验:第一次实验直接对精神神经进行操作,左侧绵羊和右侧绵羊分别在十秒钟和三十秒内接触并激活压电尖端。在第二个实验中,下牙槽神经被下颌管内的激活压电头触及,左侧为十秒钟,右侧为三十秒。所有神经样本都进行了组织病理学评估,并采用评分系统对神经结构进行评估。暴露于压电头 10 秒的精神神经显示出轻度异常,包括神经周围膜破坏,而神经内膜保持完好。暴露 30 秒的精神神经显示出中度损伤,神经周围被破坏,神经纤维中度变性,但神经内膜仍保持连续,Ranvier 节正常。下肺泡神经在压电尖端暴露 10 秒后出现严重损伤,表现为神经被膜脱落,神经纤维严重空泡变性,内膜部分破坏,但轴突仍然完整。暴露 30 秒的下齿槽神经显示神经外膜破坏、神经纤维明显空泡变性、轴突局灶性损伤和内膜缺失(轴突瘤)。压电手术器械有可能在手术过程中造成严重的神经损伤,使用时应非常小心。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Histological assessment of potential inferior alveolar nerve injury following osteotomy of the mandibular buccal cortex using a piezoelectric saw.

The present study aimed to evaluate the effect of Piezosurgery on histopathologic features of the inferior alveolar nerve (IAN) damage after osteotomy of the buccal cortex of the mandible using piezoelectric devices in Hamdani sheep. A total of ten healthy mature female sheep were included. Each side of the mandible underwent two different experiments: the first experiment operated directly on the mental nerve by touching and activating the piezo tip on the nerve for ten seconds for the left side and thirty seconds for the right side. In the second experiment, the inferior alveolar nerve was touched by an activated piezo tip inside the mandibular canal for ten seconds on the left side and thirty seconds on the right side. All the nerve samples underwent histopathological evaluation, and the scoring system was performed to assess the nerve structures. Mental nerves exposed to piezo tip for 10 seconds showed mild abnormality including disruption of the perineurium with the endoneurium remaining intact. Mental nerves exposed for 30 seconds showed moderate injury with destruction of the perineurium and moderate degeneration of nerve fibers, nevertheless, the endoneurium remained continuous with normal node of Ranvier. Severe damage of the inferior alveolar nerve was seen after exposure to piezo tip for 10 seconds, which showed sloughing of the perineurium and severe vacuolar degeneration of nerve fibers, partial disruption of the endoneurium; however, the axons were still intact. Inferior alveolar nerves exposed for 30 seconds revealed destruction of the perineurium, marked vacuolar degeneration of nerve fibers, focal damage of axon and loss of endoneurium (axonotmesis). Piezosurgery devices have the potential to cause severe nerve damage during surgery and should be used very carefully.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信