放射性核素骨 SPECT/CT 成像定量分析在椎体压缩性骨折中的价值:一项回顾性研究。

IF 2.9 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Yuhua Wang, Feifei Qiao, Na Li, Ye Liu, Yahong Long, Kang Xu, Jiantao Wang, Wanchun Zhang
{"title":"放射性核素骨 SPECT/CT 成像定量分析在椎体压缩性骨折中的价值:一项回顾性研究。","authors":"Yuhua Wang, Feifei Qiao, Na Li, Ye Liu, Yahong Long, Kang Xu, Jiantao Wang, Wanchun Zhang","doi":"10.1186/s12880-024-01452-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Most patients with osteoporosis experience vertebral compression fracture (VCF), which significantly reduces their quality of life. These patients are at a high risk of secondary VCF regardless of treatment. Thus, accurate diagnosis of VCF is important for treating and preventing new fractures. We aimed to investigate the diagnostic and predictive value of quantitative bone imaging techniques for fresh VCF.</p><p><strong>Methods: </strong>From November 2021 to March 2023, 34 patients with VCF were enrolled in this study, all of whom underwent routine <sup>99m</sup>Tc-MDP whole-body bone planar scan and local SPECT/CT imaging. The maximum standard uptake value (SUVmax) of 57 fresh VCF, 57 normal adjacent vertebrae, and 19 old VCF were measured. Based on the site of the fracture, fresh VCFs were regrouped into the intervertebral-type group and the margin-type group. Meanwhile, 52 patients who had no bone metastasis or VCFs in their bone scan were assigned to the control group. The SUVmax of 110 normal vertebral bodies and 10 old VCFs in the control group were measured.</p><p><strong>Results: </strong>The median SUVmax of fresh VCF was 19.80, which was significantly higher than the SUVmax of other groups. The receiver operator characteristic (ROC) curve showed that the cut-off value of SUVmax was 9.925 for diagnosing fresh VCF. The SUVmax in the intervertebral-type group was significantly higher than that in the margin-type group (P = 0.04). The SUVmax of normal vertebrae was higher among patients than among the control group (P<0.01), but the CT HU value showed no significant difference.</p><p><strong>Conclusion: </strong>The quantitative technique of bone SPECT/CT has a significant value in diagnosing fresh VCF. It can also determine the severity of fractures. In addition, whether the SUVs of the vertebrae adjacent to the fractured vertebra can predict re-fracture deserves further studies.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"24 1","pages":"270"},"PeriodicalIF":2.9000,"publicationDate":"2024-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11459896/pdf/","citationCount":"0","resultStr":"{\"title\":\"The value of quantitative analysis of radionuclide bone SPECT/CT imaging in vertebral compression fracture: a retrospective study.\",\"authors\":\"Yuhua Wang, Feifei Qiao, Na Li, Ye Liu, Yahong Long, Kang Xu, Jiantao Wang, Wanchun Zhang\",\"doi\":\"10.1186/s12880-024-01452-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Most patients with osteoporosis experience vertebral compression fracture (VCF), which significantly reduces their quality of life. These patients are at a high risk of secondary VCF regardless of treatment. Thus, accurate diagnosis of VCF is important for treating and preventing new fractures. We aimed to investigate the diagnostic and predictive value of quantitative bone imaging techniques for fresh VCF.</p><p><strong>Methods: </strong>From November 2021 to March 2023, 34 patients with VCF were enrolled in this study, all of whom underwent routine <sup>99m</sup>Tc-MDP whole-body bone planar scan and local SPECT/CT imaging. The maximum standard uptake value (SUVmax) of 57 fresh VCF, 57 normal adjacent vertebrae, and 19 old VCF were measured. Based on the site of the fracture, fresh VCFs were regrouped into the intervertebral-type group and the margin-type group. Meanwhile, 52 patients who had no bone metastasis or VCFs in their bone scan were assigned to the control group. The SUVmax of 110 normal vertebral bodies and 10 old VCFs in the control group were measured.</p><p><strong>Results: </strong>The median SUVmax of fresh VCF was 19.80, which was significantly higher than the SUVmax of other groups. The receiver operator characteristic (ROC) curve showed that the cut-off value of SUVmax was 9.925 for diagnosing fresh VCF. The SUVmax in the intervertebral-type group was significantly higher than that in the margin-type group (P = 0.04). The SUVmax of normal vertebrae was higher among patients than among the control group (P<0.01), but the CT HU value showed no significant difference.</p><p><strong>Conclusion: </strong>The quantitative technique of bone SPECT/CT has a significant value in diagnosing fresh VCF. It can also determine the severity of fractures. In addition, whether the SUVs of the vertebrae adjacent to the fractured vertebra can predict re-fracture deserves further studies.</p>\",\"PeriodicalId\":9020,\"journal\":{\"name\":\"BMC Medical Imaging\",\"volume\":\"24 1\",\"pages\":\"270\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11459896/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Medical Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12880-024-01452-9\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-024-01452-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:大多数骨质疏松症患者都会发生椎体压缩性骨折(VCF),这大大降低了他们的生活质量。无论治疗与否,这些患者都有继发椎体压缩性骨折的高风险。因此,准确诊断 VCF 对治疗和预防新的骨折非常重要。我们旨在研究定量骨成像技术对新鲜 VCF 的诊断和预测价值:方法:2021 年 11 月至 2023 年 3 月,本研究共纳入 34 例 VCF 患者,所有患者均接受了常规 99mTc-MDP 全身骨平面扫描和局部 SPECT/CT 成像检查。测量了 57 个新鲜 VCF、57 个正常邻近椎体和 19 个陈旧 VCF 的最大标准摄取值(SUVmax)。根据骨折部位,将新鲜椎体后凸面分为椎间型和边缘型两组。同时,将 52 名骨扫描中未发现骨转移或 VCF 的患者列为对照组。测量对照组 110 个正常椎体和 10 个陈旧 VCF 的 SUVmax:结果:新鲜 VCF 的 SUVmax 中位数为 19.80,明显高于其他组的 SUVmax。接收器操作特征曲线(ROC)显示,诊断新鲜 VCF 的 SUVmax 临界值为 9.925。椎间型组的 SUVmax 明显高于边缘型组(P = 0.04)。正常椎体的 SUVmax 在患者中高于对照组(PC 结论:骨 SPECT-X 定量技术可用于 VCF 的诊断:骨 SPECT/CT 定量技术在诊断新鲜 VCF 方面具有重要价值。它还能确定骨折的严重程度。此外,骨折椎体邻近椎体的 SUV 值能否预测再次骨折也值得进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The value of quantitative analysis of radionuclide bone SPECT/CT imaging in vertebral compression fracture: a retrospective study.

Background: Most patients with osteoporosis experience vertebral compression fracture (VCF), which significantly reduces their quality of life. These patients are at a high risk of secondary VCF regardless of treatment. Thus, accurate diagnosis of VCF is important for treating and preventing new fractures. We aimed to investigate the diagnostic and predictive value of quantitative bone imaging techniques for fresh VCF.

Methods: From November 2021 to March 2023, 34 patients with VCF were enrolled in this study, all of whom underwent routine 99mTc-MDP whole-body bone planar scan and local SPECT/CT imaging. The maximum standard uptake value (SUVmax) of 57 fresh VCF, 57 normal adjacent vertebrae, and 19 old VCF were measured. Based on the site of the fracture, fresh VCFs were regrouped into the intervertebral-type group and the margin-type group. Meanwhile, 52 patients who had no bone metastasis or VCFs in their bone scan were assigned to the control group. The SUVmax of 110 normal vertebral bodies and 10 old VCFs in the control group were measured.

Results: The median SUVmax of fresh VCF was 19.80, which was significantly higher than the SUVmax of other groups. The receiver operator characteristic (ROC) curve showed that the cut-off value of SUVmax was 9.925 for diagnosing fresh VCF. The SUVmax in the intervertebral-type group was significantly higher than that in the margin-type group (P = 0.04). The SUVmax of normal vertebrae was higher among patients than among the control group (P<0.01), but the CT HU value showed no significant difference.

Conclusion: The quantitative technique of bone SPECT/CT has a significant value in diagnosing fresh VCF. It can also determine the severity of fractures. In addition, whether the SUVs of the vertebrae adjacent to the fractured vertebra can predict re-fracture deserves further studies.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Medical Imaging
BMC Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
3.70%
发文量
198
审稿时长
27 weeks
期刊介绍: BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信