{"title":"使用显微镜线圈对牙齿和牙周组织进行高分辨率磁共振成像。","authors":"Shinya Kotaki, Hiroshi Watanabe, Junichiro Sakamoto, Ami Kuribayashi, Marino Araragi, Hironori Akiyama, Yoshiko Ariji","doi":"10.5624/isd.20240052","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to assess the performance of 2-dimensional (2D) imaging with microscopy coils in delineating teeth and periodontal tissues compared with conventional 3-dimensional (3D) imaging on a 3 T magnetic resonance imaging (MRI) unit.</p><p><strong>Materials and methods: </strong>Twelve healthy participants (4 men and 8 women; mean age: 25.6 years; range: 20-52 years) with no dental symptoms were included. The left mandibular first molars and surrounding periodontal tissues were examined using the following 2 sequences: 2D proton density-weighted (PDw) images and 3D enhanced T1 high-resolution isotropic volume excitation (eTHRIVE) images. Two-dimensional MRI images were taken using a 3 T MRI unit and a 47 mm microscopy coil, while 3D MRI imaging used a 3 T MRI unit and head-neck coil. Oral radiologists assessed dental and periodontal structures using a 4-point Likert scale. Inter- and intra-observer agreement was determined using the weighted kappa coefficient. The Wilcoxon signed-rank test was used to compare 2D-PDw and 3D-eTHRIVE images.</p><p><strong>Results: </strong>Qualitative analysis showed significantly better visualization scores for 2D-PDw imaging than for 3D-eTHRIVE imaging (Wilcoxon signed-rank test). 2D-PDw images provided improved visibility of the tooth, root dental pulp, periodontal ligament, lamina dura, coronal dental pulp, gingiva, and nutrient tract. Inter-observer reliability ranged from moderate agreement to almost perfect agreement, and intra-observer agreement was in a similar range.</p><p><strong>Conclusion: </strong>Two-dimensional-PDw images acquired using a 3 T MRI unit and microscopy coil effectively visualized nearly all aspects of teeth and periodontal tissues.</p>","PeriodicalId":51714,"journal":{"name":"Imaging Science in Dentistry","volume":"54 3","pages":"276-282"},"PeriodicalIF":1.7000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11450415/pdf/","citationCount":"0","resultStr":"{\"title\":\"High-resolution magnetic resonance imaging of teeth and periodontal tissues using a microscopy coil.\",\"authors\":\"Shinya Kotaki, Hiroshi Watanabe, Junichiro Sakamoto, Ami Kuribayashi, Marino Araragi, Hironori Akiyama, Yoshiko Ariji\",\"doi\":\"10.5624/isd.20240052\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study aimed to assess the performance of 2-dimensional (2D) imaging with microscopy coils in delineating teeth and periodontal tissues compared with conventional 3-dimensional (3D) imaging on a 3 T magnetic resonance imaging (MRI) unit.</p><p><strong>Materials and methods: </strong>Twelve healthy participants (4 men and 8 women; mean age: 25.6 years; range: 20-52 years) with no dental symptoms were included. The left mandibular first molars and surrounding periodontal tissues were examined using the following 2 sequences: 2D proton density-weighted (PDw) images and 3D enhanced T1 high-resolution isotropic volume excitation (eTHRIVE) images. Two-dimensional MRI images were taken using a 3 T MRI unit and a 47 mm microscopy coil, while 3D MRI imaging used a 3 T MRI unit and head-neck coil. Oral radiologists assessed dental and periodontal structures using a 4-point Likert scale. Inter- and intra-observer agreement was determined using the weighted kappa coefficient. The Wilcoxon signed-rank test was used to compare 2D-PDw and 3D-eTHRIVE images.</p><p><strong>Results: </strong>Qualitative analysis showed significantly better visualization scores for 2D-PDw imaging than for 3D-eTHRIVE imaging (Wilcoxon signed-rank test). 2D-PDw images provided improved visibility of the tooth, root dental pulp, periodontal ligament, lamina dura, coronal dental pulp, gingiva, and nutrient tract. Inter-observer reliability ranged from moderate agreement to almost perfect agreement, and intra-observer agreement was in a similar range.</p><p><strong>Conclusion: </strong>Two-dimensional-PDw images acquired using a 3 T MRI unit and microscopy coil effectively visualized nearly all aspects of teeth and periodontal tissues.</p>\",\"PeriodicalId\":51714,\"journal\":{\"name\":\"Imaging Science in Dentistry\",\"volume\":\"54 3\",\"pages\":\"276-282\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11450415/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Imaging Science in Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5624/isd.20240052\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging Science in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5624/isd.20240052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
目的:本研究旨在评估在 3 T 磁共振成像(MRI)设备上使用显微镜线圈进行的二维(2D)成像与传统的三维(3D)成像在勾画牙齿和牙周组织方面的性能比较:纳入 12 名无牙科症状的健康参与者(4 名男性和 8 名女性;平均年龄:25.6 岁;范围:20-52 岁)。使用以下两种序列对左下颌第一磨牙和周围牙周组织进行检查:二维质子密度加权(PDw)图像和三维增强 T1 高分辨率各向同性容积激发(eTHRIVE)图像。二维核磁共振成像使用 3 T 核磁共振成像设备和 47 毫米显微镜线圈,三维核磁共振成像使用 3 T 核磁共振成像设备和头颈线圈。口腔放射科医生采用李克特 4 点量表对牙齿和牙周结构进行评估。采用加权卡帕系数确定观察者之间和观察者内部的一致性。Wilcoxon 符号秩检验用于比较 2D-PDw 和 3D-eTHRIVE 图像:定性分析显示,2D-PDw 成像的可视化评分明显优于 3D-eTHRIVE 成像(Wilcoxon 符号秩检验)。2D-PDw 成像提高了牙齿、牙根牙髓、牙周韧带、硬膜、冠状牙髓、牙龈和营养道的可见度。观察者之间的可靠性从中度一致到几乎完全一致,观察者内部的一致性也在类似范围内:结论:使用 3 T 磁共振成像设备和显微镜线圈获取的二维-PDw 图像可有效显示牙齿和牙周组织的几乎所有方面。
High-resolution magnetic resonance imaging of teeth and periodontal tissues using a microscopy coil.
Purpose: This study aimed to assess the performance of 2-dimensional (2D) imaging with microscopy coils in delineating teeth and periodontal tissues compared with conventional 3-dimensional (3D) imaging on a 3 T magnetic resonance imaging (MRI) unit.
Materials and methods: Twelve healthy participants (4 men and 8 women; mean age: 25.6 years; range: 20-52 years) with no dental symptoms were included. The left mandibular first molars and surrounding periodontal tissues were examined using the following 2 sequences: 2D proton density-weighted (PDw) images and 3D enhanced T1 high-resolution isotropic volume excitation (eTHRIVE) images. Two-dimensional MRI images were taken using a 3 T MRI unit and a 47 mm microscopy coil, while 3D MRI imaging used a 3 T MRI unit and head-neck coil. Oral radiologists assessed dental and periodontal structures using a 4-point Likert scale. Inter- and intra-observer agreement was determined using the weighted kappa coefficient. The Wilcoxon signed-rank test was used to compare 2D-PDw and 3D-eTHRIVE images.
Results: Qualitative analysis showed significantly better visualization scores for 2D-PDw imaging than for 3D-eTHRIVE imaging (Wilcoxon signed-rank test). 2D-PDw images provided improved visibility of the tooth, root dental pulp, periodontal ligament, lamina dura, coronal dental pulp, gingiva, and nutrient tract. Inter-observer reliability ranged from moderate agreement to almost perfect agreement, and intra-observer agreement was in a similar range.
Conclusion: Two-dimensional-PDw images acquired using a 3 T MRI unit and microscopy coil effectively visualized nearly all aspects of teeth and periodontal tissues.