W K Zhou, J J Wang, Y H Jiang, L Yang, Y L Luo, Y Man, J Wang
{"title":"机器人计算机辅助植入手术的临床和体外应用:范围综述。","authors":"W K Zhou, J J Wang, Y H Jiang, L Yang, Y L Luo, Y Man, J Wang","doi":"10.1016/j.ijom.2024.09.006","DOIUrl":null,"url":null,"abstract":"<p><p>In recent years, the emergence and application of robotic computer-assisted implant surgery (r-CAIS) has resulted in a revolutionary shift in conventional implant diagnosis and treatment. This scoping review was performed to verify the null hypothesis that r-CAIS has a relatively high accuracy of within 1 mm, with relatively few complications and a short operative time. This review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews (PRISMA-ScR). From the 3355 publications identified in the PubMed, Scopus, Web of Science, and Google Scholar databases, 28 were finally included after a comprehensive review and analysis. The null hypothesis is partly accepted, as r-CAIS has a relatively high accuracy (coronal and apical deviation within 1 mm), and no significant adverse events or complications have been reported to date, although additional confirmatory studies are needed. However, there is insufficient evidence for a shorter surgical time, and further clinical research on this topic is required.</p>","PeriodicalId":94053,"journal":{"name":"International journal of oral and maxillofacial surgery","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical and in vitro application of robotic computer-assisted implant surgery: a scoping review.\",\"authors\":\"W K Zhou, J J Wang, Y H Jiang, L Yang, Y L Luo, Y Man, J Wang\",\"doi\":\"10.1016/j.ijom.2024.09.006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In recent years, the emergence and application of robotic computer-assisted implant surgery (r-CAIS) has resulted in a revolutionary shift in conventional implant diagnosis and treatment. This scoping review was performed to verify the null hypothesis that r-CAIS has a relatively high accuracy of within 1 mm, with relatively few complications and a short operative time. This review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews (PRISMA-ScR). From the 3355 publications identified in the PubMed, Scopus, Web of Science, and Google Scholar databases, 28 were finally included after a comprehensive review and analysis. The null hypothesis is partly accepted, as r-CAIS has a relatively high accuracy (coronal and apical deviation within 1 mm), and no significant adverse events or complications have been reported to date, although additional confirmatory studies are needed. However, there is insufficient evidence for a shorter surgical time, and further clinical research on this topic is required.</p>\",\"PeriodicalId\":94053,\"journal\":{\"name\":\"International journal of oral and maxillofacial surgery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of oral and maxillofacial surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/j.ijom.2024.09.006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of oral and maxillofacial surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.ijom.2024.09.006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
近年来,机器人计算机辅助种植手术(r-CAIS)的出现和应用为传统的种植诊断和治疗带来了革命性的转变。本范围性综述旨在验证以下零假设:r-CAIS 的准确度相对较高,在 1 毫米以内,并发症相对较少,手术时间较短。本综述按照《系统综述和荟萃分析的首选报告项目》(Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews,PRISMA-ScR)进行。从 PubMed、Scopus、Web of Science 和 Google Scholar 数据库中找到的 3355 篇出版物中,经过全面审查和分析,最终纳入了 28 篇。零假设被部分接受,因为 r-CAIS 具有相对较高的准确性(冠状面和心尖偏差在 1 毫米以内),而且迄今为止尚未有重大不良事件或并发症的报道,但仍需进行更多的确证研究。不过,目前还没有足够的证据表明手术时间更短,因此还需要进一步的临床研究。
Clinical and in vitro application of robotic computer-assisted implant surgery: a scoping review.
In recent years, the emergence and application of robotic computer-assisted implant surgery (r-CAIS) has resulted in a revolutionary shift in conventional implant diagnosis and treatment. This scoping review was performed to verify the null hypothesis that r-CAIS has a relatively high accuracy of within 1 mm, with relatively few complications and a short operative time. This review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews (PRISMA-ScR). From the 3355 publications identified in the PubMed, Scopus, Web of Science, and Google Scholar databases, 28 were finally included after a comprehensive review and analysis. The null hypothesis is partly accepted, as r-CAIS has a relatively high accuracy (coronal and apical deviation within 1 mm), and no significant adverse events or complications have been reported to date, although additional confirmatory studies are needed. However, there is insufficient evidence for a shorter surgical time, and further clinical research on this topic is required.