内部 CAD/CAM 制作的复位导板,用于 Le Fort I 截骨术后的上颌骨复位。

IF 2.2 3区 医学 Q2 Dentistry
Jin-Yong Cho, Jaeyoung Ryu, Seunggon Jung, Min-Suk Kook, Hong-Ju Park, Hee-Kyun Oh
{"title":"内部 CAD/CAM 制作的复位导板,用于 Le Fort I 截骨术后的上颌骨复位。","authors":"Jin-Yong Cho, Jaeyoung Ryu, Seunggon Jung, Min-Suk Kook, Hong-Ju Park, Hee-Kyun Oh","doi":"10.1016/j.jormas.2024.102102","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to compare the accuracy of two transferring methods, which are the intermediate splint made by computer-aided design (CAD)/computer-aided manufacturing (CAM) and the customized maxillary repositioning guide for orthognathic surgery.</p><p><strong>Materials and methods: </strong>Patient data regarding virtual surgical simulations were collected. For analyzing the accuracy, the postoperative cone-beam computed tomography and preoperative simulation data were superimposed. The x, y, and z coordinates were obtained at three landmarks in the maxillary dentition, and the linear and angular differences between the surgical simulation and the actual surgery were evaluated.</p><p><strong>Results: </strong>Thirty-three patients were included in this study, 16 in the splint group and 17 in the guide group. One coordinate in the guide group and nine in the splint group showed errors of >2 mm, with a statistically significant difference. There was no significant difference between the two groups in the three-dimensional error distance at each reference point. In most measurements, the interquartile range of the guide group showed a narrower distribution than that of the splint group.</p><p><strong>Conclusion: </strong>It is more advantageous to use a customized maxillary repositioning guide than an intermediate splint made via CAD/CAM to obtain an accuracy within the 2 mm discrepancy range.</p>","PeriodicalId":56038,"journal":{"name":"Journal of Stomatology Oral and Maxillofacial Surgery","volume":" ","pages":"102102"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In-house CAD/CAM fabricated repositioning guide in maxillary repositioning after Le Fort I osteotomy.\",\"authors\":\"Jin-Yong Cho, Jaeyoung Ryu, Seunggon Jung, Min-Suk Kook, Hong-Ju Park, Hee-Kyun Oh\",\"doi\":\"10.1016/j.jormas.2024.102102\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study aimed to compare the accuracy of two transferring methods, which are the intermediate splint made by computer-aided design (CAD)/computer-aided manufacturing (CAM) and the customized maxillary repositioning guide for orthognathic surgery.</p><p><strong>Materials and methods: </strong>Patient data regarding virtual surgical simulations were collected. For analyzing the accuracy, the postoperative cone-beam computed tomography and preoperative simulation data were superimposed. The x, y, and z coordinates were obtained at three landmarks in the maxillary dentition, and the linear and angular differences between the surgical simulation and the actual surgery were evaluated.</p><p><strong>Results: </strong>Thirty-three patients were included in this study, 16 in the splint group and 17 in the guide group. One coordinate in the guide group and nine in the splint group showed errors of >2 mm, with a statistically significant difference. There was no significant difference between the two groups in the three-dimensional error distance at each reference point. In most measurements, the interquartile range of the guide group showed a narrower distribution than that of the splint group.</p><p><strong>Conclusion: </strong>It is more advantageous to use a customized maxillary repositioning guide than an intermediate splint made via CAD/CAM to obtain an accuracy within the 2 mm discrepancy range.</p>\",\"PeriodicalId\":56038,\"journal\":{\"name\":\"Journal of Stomatology Oral and Maxillofacial Surgery\",\"volume\":\" \",\"pages\":\"102102\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Stomatology Oral and Maxillofacial Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.jormas.2024.102102\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Stomatology Oral and Maxillofacial Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jormas.2024.102102","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在比较两种转移方法的准确性,一种是计算机辅助设计(CAD)/计算机辅助制造(CAM)制作的中间夹板,另一种是为正颌外科手术定制的上颌骨复位指南:收集虚拟手术模拟的患者数据。为了分析准确性,将术后锥束计算机断层扫描数据和术前模拟数据进行了叠加。在上颌牙体的三个地标处获得 x、y 和 z 坐标,并评估手术模拟与实际手术之间的线性和角度差异:本研究共纳入 33 名患者,其中夹板组 16 人,导板组 17 人。导板组有 1 个坐标和夹板组有 9 个坐标的误差超过 2 毫米,差异有统计学意义。两组在每个参考点的三维误差距离没有明显差异。在大多数测量中,导板组的四分位间分布范围比夹板组窄:结论:与通过 CAD/CAM 制作的中间夹板相比,使用定制的上颌复位引导器更有利于获得 2 毫米误差范围内的精确度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In-house CAD/CAM fabricated repositioning guide in maxillary repositioning after Le Fort I osteotomy.

Objective: This study aimed to compare the accuracy of two transferring methods, which are the intermediate splint made by computer-aided design (CAD)/computer-aided manufacturing (CAM) and the customized maxillary repositioning guide for orthognathic surgery.

Materials and methods: Patient data regarding virtual surgical simulations were collected. For analyzing the accuracy, the postoperative cone-beam computed tomography and preoperative simulation data were superimposed. The x, y, and z coordinates were obtained at three landmarks in the maxillary dentition, and the linear and angular differences between the surgical simulation and the actual surgery were evaluated.

Results: Thirty-three patients were included in this study, 16 in the splint group and 17 in the guide group. One coordinate in the guide group and nine in the splint group showed errors of >2 mm, with a statistically significant difference. There was no significant difference between the two groups in the three-dimensional error distance at each reference point. In most measurements, the interquartile range of the guide group showed a narrower distribution than that of the splint group.

Conclusion: It is more advantageous to use a customized maxillary repositioning guide than an intermediate splint made via CAD/CAM to obtain an accuracy within the 2 mm discrepancy range.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.20
自引率
9.10%
发文量
305
期刊介绍: J Stomatol Oral Maxillofac Surg publishes research papers and techniques - (guest) editorials, original articles, reviews, technical notes, case reports, images, letters to the editor, guidelines - dedicated to enhancing surgical expertise in all fields relevant to oral and maxillofacial surgery: from plastic and reconstructive surgery of the face, oral surgery and medicine, … to dentofacial and maxillofacial orthopedics. Original articles include clinical or laboratory investigations and clinical or equipment reports. Reviews include narrative reviews, systematic reviews and meta-analyses. All manuscripts submitted to the journal are subjected to peer review by international experts, and must: Be written in excellent English, clear and easy to understand, precise and concise; Bring new, interesting, valid information - and improve clinical care or guide future research; Be solely the work of the author(s) stated; Not have been previously published elsewhere and not be under consideration by another journal; Be in accordance with the journal''s Guide for Authors'' instructions: manuscripts that fail to comply with these rules may be returned to the authors without being reviewed. Under no circumstances does the journal guarantee publication before the editorial board makes its final decision. The journal is indexed in the main international databases and is accessible worldwide through the ScienceDirect and ClinicalKey Platforms.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信