Matthew Simpson, Julie Scott, Lara Bonney, Rachael Clitheroe, Daniel R McGowan
{"title":"开发在英国紧急情况下使用标准医院伽马相机作为分诊全身监测仪的方法。","authors":"Matthew Simpson, Julie Scott, Lara Bonney, Rachael Clitheroe, Daniel R McGowan","doi":"10.1088/1361-6498/ad82f5","DOIUrl":null,"url":null,"abstract":"<p><p>This paper outlines the process by which a medical gamma camera can be utilised to support assessment of internal radionuclides for the public. While hospital based gamma cameras are able to detect photopeaks, they are often limited to an energy range of 40-540 keV. However, radionuclides with photopeak energies above 540 keV can still be detected as the partial collection of photon energy increases the count rate at lower energies. By combining extensive mathematical modelling with empirical calibration of multiple gamma cameras it is possible to develop a linear correlation between the efficiency of counting point sources and the overall counting efficiency for the camera. Once established, a simple protocol can be used to characterise any gamma camera, using optimal system settings, and hence generate a system efficiency with sufficient accuracy to allow the camera to be used in a triage process to committed effective doses of 2 mSv.
.</p>","PeriodicalId":50068,"journal":{"name":"Journal of Radiological Protection","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a method to use standard hospital gamma cameras as triage whole body monitors in UK emergencies.\",\"authors\":\"Matthew Simpson, Julie Scott, Lara Bonney, Rachael Clitheroe, Daniel R McGowan\",\"doi\":\"10.1088/1361-6498/ad82f5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper outlines the process by which a medical gamma camera can be utilised to support assessment of internal radionuclides for the public. While hospital based gamma cameras are able to detect photopeaks, they are often limited to an energy range of 40-540 keV. However, radionuclides with photopeak energies above 540 keV can still be detected as the partial collection of photon energy increases the count rate at lower energies. By combining extensive mathematical modelling with empirical calibration of multiple gamma cameras it is possible to develop a linear correlation between the efficiency of counting point sources and the overall counting efficiency for the camera. Once established, a simple protocol can be used to characterise any gamma camera, using optimal system settings, and hence generate a system efficiency with sufficient accuracy to allow the camera to be used in a triage process to committed effective doses of 2 mSv.
.</p>\",\"PeriodicalId\":50068,\"journal\":{\"name\":\"Journal of Radiological Protection\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radiological Protection\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1088/1361-6498/ad82f5\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiological Protection","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1088/1361-6498/ad82f5","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Development of a method to use standard hospital gamma cameras as triage whole body monitors in UK emergencies.
This paper outlines the process by which a medical gamma camera can be utilised to support assessment of internal radionuclides for the public. While hospital based gamma cameras are able to detect photopeaks, they are often limited to an energy range of 40-540 keV. However, radionuclides with photopeak energies above 540 keV can still be detected as the partial collection of photon energy increases the count rate at lower energies. By combining extensive mathematical modelling with empirical calibration of multiple gamma cameras it is possible to develop a linear correlation between the efficiency of counting point sources and the overall counting efficiency for the camera. Once established, a simple protocol can be used to characterise any gamma camera, using optimal system settings, and hence generate a system efficiency with sufficient accuracy to allow the camera to be used in a triage process to committed effective doses of 2 mSv.
.
期刊介绍:
Journal of Radiological Protection publishes articles on all aspects of radiological protection, including non-ionising as well as ionising radiations. Fields of interest range from research, development and theory to operational matters, education and training. The very wide spectrum of its topics includes: dosimetry, instrument development, specialized measuring techniques, epidemiology, biological effects (in vivo and in vitro) and risk and environmental impact assessments.
The journal encourages publication of data and code as well as results.