光子计数探测器计算机断层扫描在心脏成像中的应用。

IF 1.7 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Netherlands Heart Journal Pub Date : 2024-11-01 Epub Date: 2024-10-02 DOI:10.1007/s12471-024-01904-5
Simran P Sharma, Marie-Julie D K Lemmens, Martijn W Smulders, Ricardo P J Budde, Alexander Hirsch, Casper Mihl
{"title":"光子计数探测器计算机断层扫描在心脏成像中的应用。","authors":"Simran P Sharma, Marie-Julie D K Lemmens, Martijn W Smulders, Ricardo P J Budde, Alexander Hirsch, Casper Mihl","doi":"10.1007/s12471-024-01904-5","DOIUrl":null,"url":null,"abstract":"<p><p>Photon-counting detector computed tomography (PCD-CT) has emerged as a revolutionary technology in CT imaging. PCD-CT offers significant advancements over conventional energy-integrating detector CT, including increased spatial resolution, artefact reduction and inherent spectral imaging capabilities. In cardiac imaging, PCD-CT can offer a more accurate assessment of coronary artery disease, plaque characterisation and the in-stent lumen. Additionally, it might improve the visualisation of myocardial fibrosis through qualitative late enhancement imaging and quantitative extracellular volume measurements. The use of PCD-CT in cardiac imaging holds significant potential, positioning itself as a valuable modality that could serve as a one-stop-shop by integrating both angiography and tissue characterisation into a single examination. Despite its potential, large-scale clinical trials, standardisation of protocols and cost-effectiveness considerations are required for its broader integration into clinical practice. This narrative review provides an overview of the current literature on PCD-CT regarding the possibilities and limitations of cardiac imaging.</p>","PeriodicalId":18952,"journal":{"name":"Netherlands Heart Journal","volume":" ","pages":"405-416"},"PeriodicalIF":1.7000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11502613/pdf/","citationCount":"0","resultStr":"{\"title\":\"Photon-counting detector computed tomography in cardiac imaging.\",\"authors\":\"Simran P Sharma, Marie-Julie D K Lemmens, Martijn W Smulders, Ricardo P J Budde, Alexander Hirsch, Casper Mihl\",\"doi\":\"10.1007/s12471-024-01904-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Photon-counting detector computed tomography (PCD-CT) has emerged as a revolutionary technology in CT imaging. PCD-CT offers significant advancements over conventional energy-integrating detector CT, including increased spatial resolution, artefact reduction and inherent spectral imaging capabilities. In cardiac imaging, PCD-CT can offer a more accurate assessment of coronary artery disease, plaque characterisation and the in-stent lumen. Additionally, it might improve the visualisation of myocardial fibrosis through qualitative late enhancement imaging and quantitative extracellular volume measurements. The use of PCD-CT in cardiac imaging holds significant potential, positioning itself as a valuable modality that could serve as a one-stop-shop by integrating both angiography and tissue characterisation into a single examination. Despite its potential, large-scale clinical trials, standardisation of protocols and cost-effectiveness considerations are required for its broader integration into clinical practice. This narrative review provides an overview of the current literature on PCD-CT regarding the possibilities and limitations of cardiac imaging.</p>\",\"PeriodicalId\":18952,\"journal\":{\"name\":\"Netherlands Heart Journal\",\"volume\":\" \",\"pages\":\"405-416\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11502613/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Netherlands Heart Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s12471-024-01904-5\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/2 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Netherlands Heart Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12471-024-01904-5","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/2 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

光子计数探测器计算机断层扫描(PCD-CT)已成为 CT 成像领域的一项革命性技术。与传统的能量积分探测器 CT 相比,PCD-CT 具有明显的进步,包括提高空间分辨率、减少伪影和固有的光谱成像能力。在心脏成像中,PCD-CT 可以更准确地评估冠状动脉疾病、斑块特征和支架内腔。此外,它还可以通过定性的后期增强成像和定量的细胞外体积测量,改善心肌纤维化的可视化。PCD-CT 在心脏成像中的应用潜力巨大,它将自己定位为一种有价值的模式,可将血管造影和组织特征描述整合到一次检查中,从而提供一站式服务。尽管其潜力巨大,但要将其更广泛地应用于临床实践,还需要进行大规模临床试验、标准化方案和成本效益考量。这篇叙述性综述概述了目前有关 PCD-CT 的文献,涉及心脏成像的可能性和局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Photon-counting detector computed tomography in cardiac imaging.

Photon-counting detector computed tomography (PCD-CT) has emerged as a revolutionary technology in CT imaging. PCD-CT offers significant advancements over conventional energy-integrating detector CT, including increased spatial resolution, artefact reduction and inherent spectral imaging capabilities. In cardiac imaging, PCD-CT can offer a more accurate assessment of coronary artery disease, plaque characterisation and the in-stent lumen. Additionally, it might improve the visualisation of myocardial fibrosis through qualitative late enhancement imaging and quantitative extracellular volume measurements. The use of PCD-CT in cardiac imaging holds significant potential, positioning itself as a valuable modality that could serve as a one-stop-shop by integrating both angiography and tissue characterisation into a single examination. Despite its potential, large-scale clinical trials, standardisation of protocols and cost-effectiveness considerations are required for its broader integration into clinical practice. This narrative review provides an overview of the current literature on PCD-CT regarding the possibilities and limitations of cardiac imaging.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Netherlands Heart Journal
Netherlands Heart Journal CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
4.70
自引率
5.00%
发文量
84
审稿时长
6-12 weeks
期刊介绍: The scope of the Netherlands Heart Journal is to contribute to the national and international literature by publishing scientific papers in the field of cardiovascular medicine. It also provides a platform for Continuing Medical Education for cardiologists and those in training for the speciality of cardiology in the Netherlands. The Netherlands Heart Journal is made available to cardiologists, cardiologists in training, cardiopulmonary surgeons, cardiopulmonary surgeons in training, internists and paediatric cardiologists. The journal is the official journal of the Netherlands Society of Cardiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信