Bairi Levi Rakshith , Lazarus Godson Asirvatham , Appadurai Anitha Angeline , Bryan Lancy , J Perinba Selvin Raj , Jefferson Raja Bose , Somchai Wongwises
{"title":"嵌入内部冷却冷凝器的新型椭圆槽扁平热管系统的热管理性能","authors":"Bairi Levi Rakshith , Lazarus Godson Asirvatham , Appadurai Anitha Angeline , Bryan Lancy , J Perinba Selvin Raj , Jefferson Raja Bose , Somchai Wongwises","doi":"10.1016/j.ecmx.2024.100717","DOIUrl":null,"url":null,"abstract":"<div><div>Flat heat pipes (FHPs) with rectangular groove wick structures fail to sufficiently uplift the working fluid’s liquid meniscus to cover the upper sides of the groove walls due to the vertically flat wall design. This results in the formation of non-evaporative zones, particularly in the evaporator region, leading to elevated wall temperatures at high heat loads. To address this issue, a novel FHP with elliptical grooves as wick is designed and tested across heat loads ranging from 30 to 360 W. Elliptical groove depths of 0.5 mm and 0.7 mm are evaluated and compared to FHPs with rectangular grooves. Results showed that at 360 W, the 0.7 mm depth elliptical grooves resulted in 6.5 % reduction in evaporator wall temperature and 27.8 % reduction in thermal resistance, along with 31.5 % enhancement in effective thermal conductivity compared to rectangular grooves. The curvature of the elliptical grooves, combined with enhanced surface tension effects of the working fluid, efficiently uplifted the liquid meniscus to cover the upper wall of the groove, minimizing non-evaporative zones. Additionally, FHPs with elliptical grooves demonstrated lower entropy generation, indicating higher thermal efficiency. Consequently, FHPs with elliptical groove designs are concluded to be an efficient and suitable solution for the thermal management of miniaturized electronic devices.</div></div>","PeriodicalId":37131,"journal":{"name":"Energy Conversion and Management-X","volume":"24 ","pages":"Article 100717"},"PeriodicalIF":7.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal management performance of a novel elliptically grooved flat heat pipe system embedded with internally cooled condenser\",\"authors\":\"Bairi Levi Rakshith , Lazarus Godson Asirvatham , Appadurai Anitha Angeline , Bryan Lancy , J Perinba Selvin Raj , Jefferson Raja Bose , Somchai Wongwises\",\"doi\":\"10.1016/j.ecmx.2024.100717\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><div>Flat heat pipes (FHPs) with rectangular groove wick structures fail to sufficiently uplift the working fluid’s liquid meniscus to cover the upper sides of the groove walls due to the vertically flat wall design. This results in the formation of non-evaporative zones, particularly in the evaporator region, leading to elevated wall temperatures at high heat loads. To address this issue, a novel FHP with elliptical grooves as wick is designed and tested across heat loads ranging from 30 to 360 W. Elliptical groove depths of 0.5 mm and 0.7 mm are evaluated and compared to FHPs with rectangular grooves. Results showed that at 360 W, the 0.7 mm depth elliptical grooves resulted in 6.5 % reduction in evaporator wall temperature and 27.8 % reduction in thermal resistance, along with 31.5 % enhancement in effective thermal conductivity compared to rectangular grooves. The curvature of the elliptical grooves, combined with enhanced surface tension effects of the working fluid, efficiently uplifted the liquid meniscus to cover the upper wall of the groove, minimizing non-evaporative zones. Additionally, FHPs with elliptical grooves demonstrated lower entropy generation, indicating higher thermal efficiency. Consequently, FHPs with elliptical groove designs are concluded to be an efficient and suitable solution for the thermal management of miniaturized electronic devices.</div></div>\",\"PeriodicalId\":37131,\"journal\":{\"name\":\"Energy Conversion and Management-X\",\"volume\":\"24 \",\"pages\":\"Article 100717\"},\"PeriodicalIF\":7.1000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Conversion and Management-X\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2590174524001958\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management-X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590174524001958","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
摘要
采用矩形槽芯结构的扁平热管 (FHP) 由于采用垂直扁平的管壁设计,工作流体的液体半月板无法充分上浮以覆盖槽壁的上侧。这就形成了非蒸发区,尤其是在蒸发器区域,导致在高热负荷下壁温升高。为了解决这个问题,我们设计了一种新型的全功率变流器,采用椭圆形凹槽作为灯芯,并在 30 到 360 W 的热负荷范围内进行了测试。结果表明,在功率为 360 W 时,与矩形凹槽相比,0.7 mm 深的椭圆形凹槽使蒸发器壁温降低了 6.5%,热阻降低了 27.8%,有效热传导率提高了 31.5%。椭圆形凹槽的弧度与工作流体表面张力效应的增强相结合,有效地将液体半月板提升到凹槽上壁,最大限度地减少了非蒸发区。此外,带有椭圆形凹槽的 FHP 产生的熵值较低,表明热效率较高。因此,采用椭圆形凹槽设计的 FHP 是微型电子设备热管理的一种高效、合适的解决方案。
Thermal management performance of a novel elliptically grooved flat heat pipe system embedded with internally cooled condenser
Flat heat pipes (FHPs) with rectangular groove wick structures fail to sufficiently uplift the working fluid’s liquid meniscus to cover the upper sides of the groove walls due to the vertically flat wall design. This results in the formation of non-evaporative zones, particularly in the evaporator region, leading to elevated wall temperatures at high heat loads. To address this issue, a novel FHP with elliptical grooves as wick is designed and tested across heat loads ranging from 30 to 360 W. Elliptical groove depths of 0.5 mm and 0.7 mm are evaluated and compared to FHPs with rectangular grooves. Results showed that at 360 W, the 0.7 mm depth elliptical grooves resulted in 6.5 % reduction in evaporator wall temperature and 27.8 % reduction in thermal resistance, along with 31.5 % enhancement in effective thermal conductivity compared to rectangular grooves. The curvature of the elliptical grooves, combined with enhanced surface tension effects of the working fluid, efficiently uplifted the liquid meniscus to cover the upper wall of the groove, minimizing non-evaporative zones. Additionally, FHPs with elliptical grooves demonstrated lower entropy generation, indicating higher thermal efficiency. Consequently, FHPs with elliptical groove designs are concluded to be an efficient and suitable solution for the thermal management of miniaturized electronic devices.
期刊介绍:
Energy Conversion and Management: X is the open access extension of the reputable journal Energy Conversion and Management, serving as a platform for interdisciplinary research on a wide array of critical energy subjects. The journal is dedicated to publishing original contributions and in-depth technical review articles that present groundbreaking research on topics spanning energy generation, utilization, conversion, storage, transmission, conservation, management, and sustainability.
The scope of Energy Conversion and Management: X encompasses various forms of energy, including mechanical, thermal, nuclear, chemical, electromagnetic, magnetic, and electric energy. It addresses all known energy resources, highlighting both conventional sources like fossil fuels and nuclear power, as well as renewable resources such as solar, biomass, hydro, wind, geothermal, and ocean energy.