使用自动免疫测定法评估孕妇体内 25- 羟维生素 D 的实验室注意事项

IF 1.7 Q3 MEDICAL LABORATORY TECHNOLOGY
Darya Ayad Khalid , Bijan Nouri , Shakhawan Abdulrahman Mustafa , Mohammad Abdi
{"title":"使用自动免疫测定法评估孕妇体内 25- 羟维生素 D 的实验室注意事项","authors":"Darya Ayad Khalid ,&nbsp;Bijan Nouri ,&nbsp;Shakhawan Abdulrahman Mustafa ,&nbsp;Mohammad Abdi","doi":"10.1016/j.plabm.2024.e00430","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Because of the pathophysiological role of vitamin D in health, there is an increased interest to check the clinical status of this vitamin. Immunochemical assays are commonly employed to determine 25-hydroxyvitamin D (25 (OH) D) in clinical laboratories and its testing could be influenced by pre-analytic and analytic issues. The aim of this study was to compare the 25(OH)D results obtained from three commonly used immunoassays in pregnant women to check a possible discrepancy between tests.</div></div><div><h3>Material and methods</h3><div>A group of 50 pregnant women who were in their third trimester were included in this study. The quantification of serum vitamin D was performed utilizing three immunochemistry-based assays including Elecsys, VIDAS and Alegria. We also involved 21 non-pregnant volunteers to clinically assess the vitamin D status in this group of people.</div></div><div><h3>Results</h3><div>Our findings revealed a significant inconsistency between the obtained results from three assays for serum 25(OH)D. The 25(OH)D showed higher values when measured by the Elecsys assay while the VIDAS assay had lower values compared to the other immunoassays. More notably, the 25(OH)D testing in non-pregnant subjects showed consistent results in all three immunoassays.</div></div><div><h3>Conclusions</h3><div>The results of the 25(OH)D measurements in pregnant women should be interpreted carefully due to a great inaccuracy in immunoassay testing. There is no such disagreement in non-pregnant people. Standardization of vitamin D testing in various settings is a crucial matter for clinical laboratories.</div></div>","PeriodicalId":20421,"journal":{"name":"Practical Laboratory Medicine","volume":"42 ","pages":"Article e00430"},"PeriodicalIF":1.7000,"publicationDate":"2024-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Laboratory considerations in the assessment of 25-hydroxyvitamin D in pregnant women by automated immunoassays\",\"authors\":\"Darya Ayad Khalid ,&nbsp;Bijan Nouri ,&nbsp;Shakhawan Abdulrahman Mustafa ,&nbsp;Mohammad Abdi\",\"doi\":\"10.1016/j.plabm.2024.e00430\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><div>Because of the pathophysiological role of vitamin D in health, there is an increased interest to check the clinical status of this vitamin. Immunochemical assays are commonly employed to determine 25-hydroxyvitamin D (25 (OH) D) in clinical laboratories and its testing could be influenced by pre-analytic and analytic issues. The aim of this study was to compare the 25(OH)D results obtained from three commonly used immunoassays in pregnant women to check a possible discrepancy between tests.</div></div><div><h3>Material and methods</h3><div>A group of 50 pregnant women who were in their third trimester were included in this study. The quantification of serum vitamin D was performed utilizing three immunochemistry-based assays including Elecsys, VIDAS and Alegria. We also involved 21 non-pregnant volunteers to clinically assess the vitamin D status in this group of people.</div></div><div><h3>Results</h3><div>Our findings revealed a significant inconsistency between the obtained results from three assays for serum 25(OH)D. The 25(OH)D showed higher values when measured by the Elecsys assay while the VIDAS assay had lower values compared to the other immunoassays. More notably, the 25(OH)D testing in non-pregnant subjects showed consistent results in all three immunoassays.</div></div><div><h3>Conclusions</h3><div>The results of the 25(OH)D measurements in pregnant women should be interpreted carefully due to a great inaccuracy in immunoassay testing. There is no such disagreement in non-pregnant people. Standardization of vitamin D testing in various settings is a crucial matter for clinical laboratories.</div></div>\",\"PeriodicalId\":20421,\"journal\":{\"name\":\"Practical Laboratory Medicine\",\"volume\":\"42 \",\"pages\":\"Article e00430\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Practical Laboratory Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352551724000763\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Practical Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352551724000763","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景由于维生素 D 在健康中的病理生理作用,人们对检查这种维生素的临床状态越来越感兴趣。临床实验室通常采用免疫化学方法来测定 25- 羟基维生素 D(25 (OH) D),其检测结果可能会受到分析前和分析过程中问题的影响。本研究的目的是比较三种常用免疫测定法测定孕妇 25(OH)D 的结果,以检查不同检测方法之间可能存在的差异。使用三种基于免疫化学的检测方法(包括 Elecsys、VIDAS 和 Alegria)对血清维生素 D 进行定量。我们还邀请了 21 名非孕妇志愿者对这部分人群的维生素 D 状态进行临床评估。与其他免疫测定法相比,Elecsys 法测定的 25(OH)D 值较高,而 VIDAS 法测定的 25(OH)D 值较低。更值得注意的是,在对非孕妇进行 25(OH)D 检测时,所有三种免疫测定法的结果都是一致的。在非孕妇中则没有这种分歧。对临床实验室来说,在不同环境中进行维生素 D 检测的标准化至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Laboratory considerations in the assessment of 25-hydroxyvitamin D in pregnant women by automated immunoassays

Laboratory considerations in the assessment of 25-hydroxyvitamin D in pregnant women by automated immunoassays

Background

Because of the pathophysiological role of vitamin D in health, there is an increased interest to check the clinical status of this vitamin. Immunochemical assays are commonly employed to determine 25-hydroxyvitamin D (25 (OH) D) in clinical laboratories and its testing could be influenced by pre-analytic and analytic issues. The aim of this study was to compare the 25(OH)D results obtained from three commonly used immunoassays in pregnant women to check a possible discrepancy between tests.

Material and methods

A group of 50 pregnant women who were in their third trimester were included in this study. The quantification of serum vitamin D was performed utilizing three immunochemistry-based assays including Elecsys, VIDAS and Alegria. We also involved 21 non-pregnant volunteers to clinically assess the vitamin D status in this group of people.

Results

Our findings revealed a significant inconsistency between the obtained results from three assays for serum 25(OH)D. The 25(OH)D showed higher values when measured by the Elecsys assay while the VIDAS assay had lower values compared to the other immunoassays. More notably, the 25(OH)D testing in non-pregnant subjects showed consistent results in all three immunoassays.

Conclusions

The results of the 25(OH)D measurements in pregnant women should be interpreted carefully due to a great inaccuracy in immunoassay testing. There is no such disagreement in non-pregnant people. Standardization of vitamin D testing in various settings is a crucial matter for clinical laboratories.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Practical Laboratory Medicine
Practical Laboratory Medicine Health Professions-Radiological and Ultrasound Technology
CiteScore
3.50
自引率
0.00%
发文量
40
审稿时长
7 weeks
期刊介绍: Practical Laboratory Medicine is a high-quality, peer-reviewed, international open-access journal publishing original research, new methods and critical evaluations, case reports and short papers in the fields of clinical chemistry and laboratory medicine. The objective of the journal is to provide practical information of immediate relevance to workers in clinical laboratories. The primary scope of the journal covers clinical chemistry, hematology, molecular biology and genetics relevant to laboratory medicine, microbiology, immunology, therapeutic drug monitoring and toxicology, laboratory management and informatics. We welcome papers which describe critical evaluations of biomarkers and their role in the diagnosis and treatment of clinically significant disease, validation of commercial and in-house IVD methods, method comparisons, interference reports, the development of new reagents and reference materials, reference range studies and regulatory compliance reports. Manuscripts describing the development of new methods applicable to laboratory medicine (including point-of-care testing) are particularly encouraged, even if preliminary or small scale.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信