比较测量健康猫眼内压的三种方法。

IF 1.7 Q2 AGRICULTURE, DAIRY & ANIMAL SCIENCE
Veterinary World Pub Date : 2024-08-01 Epub Date: 2024-08-20 DOI:10.14202/vetworld.2024.1803-1809
Claudia Lizandra Ricci, João Victor Goulart Consoni Passareli, Felipe Franco Nascimento, Glaucia Prada Kanashiro, Luís Felipe da Costa Zulim, Rogério Giuffrida, Silvia Franco Andrade
{"title":"比较测量健康猫眼内压的三种方法。","authors":"Claudia Lizandra Ricci, João Victor Goulart Consoni Passareli, Felipe Franco Nascimento, Glaucia Prada Kanashiro, Luís Felipe da Costa Zulim, Rogério Giuffrida, Silvia Franco Andrade","doi":"10.14202/vetworld.2024.1803-1809","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aim: </strong>Measuring intraocular pressure (IOP) is crucial for identifying potentially damaging changes in the eyes, including diseases as glaucoma and uveitis. This study compared intraocular pressure (IOP) measurements in cats using the Tonovet and Tonovet Plus (rebound), Tono-Pen Avia Vet (applanation), and Kowa HA-2 (Goldman's methodology applanation) tonometers.</p><p><strong>Materials and methods: </strong>55 healthy cats (108 eyes) were assessed through three distinct studies: An <i>ex vivo</i> experiment (10 eyes of five cats) to correlate IOP manometry and tonometry values and ascertain the correlation coefficient (r2); an <i>in vivo</i> study (10 eyes of five sedated cats) to contrast manometer and tonometer readings; and an outpatient clinical trial (80 eyes of 45 cats) to analyze only tonometer measurements.</p><p><strong>Results: </strong>The <i>r</i> <sup>2</sup> values observed in the <i>ex vivo</i> study were Tonovet (0.923), Tonovet Plus (0.925), Tono-Pen Avia Vet (0.877), and Kowa HA-2 (0.901). The IOP values in mmHg in the <i>in vivo</i> study were as follows: Manometer (16.1 ± 2.7), Tonovet (21.1 ± 3.6), Tonovet Plus (19.7 ± 7.2), Tono-Pen Avia Vet (17.6 ± 7.9), and Kowa HA-2 (16.8 ± 2.0). In the outpatient clinical study, the IOP values in mmHg were as follows: Tonovet (19.7 ± 6.6), Tonovet Plus (17.1 ± 5.4), Tono-Pen Avia Vet (16.3 ± 4.3), and Kowa HA-2 (14.5 ± 2.2).</p><p><strong>Conclusion: </strong>IOP and manometry readings were strongly correlated by all tonometers. In the clinical setting, the most and least IOP measurements were recorded using Tonovet and Kowa HA-2, respectively, stressing the importance of an IOP reference table for each tonometer in feline practice.</p>","PeriodicalId":23587,"journal":{"name":"Veterinary World","volume":"17 8","pages":"1803-1809"},"PeriodicalIF":1.7000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11422646/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of three methodologies for measuring intraocular pressure in healthy cats.\",\"authors\":\"Claudia Lizandra Ricci, João Victor Goulart Consoni Passareli, Felipe Franco Nascimento, Glaucia Prada Kanashiro, Luís Felipe da Costa Zulim, Rogério Giuffrida, Silvia Franco Andrade\",\"doi\":\"10.14202/vetworld.2024.1803-1809\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and aim: </strong>Measuring intraocular pressure (IOP) is crucial for identifying potentially damaging changes in the eyes, including diseases as glaucoma and uveitis. This study compared intraocular pressure (IOP) measurements in cats using the Tonovet and Tonovet Plus (rebound), Tono-Pen Avia Vet (applanation), and Kowa HA-2 (Goldman's methodology applanation) tonometers.</p><p><strong>Materials and methods: </strong>55 healthy cats (108 eyes) were assessed through three distinct studies: An <i>ex vivo</i> experiment (10 eyes of five cats) to correlate IOP manometry and tonometry values and ascertain the correlation coefficient (r2); an <i>in vivo</i> study (10 eyes of five sedated cats) to contrast manometer and tonometer readings; and an outpatient clinical trial (80 eyes of 45 cats) to analyze only tonometer measurements.</p><p><strong>Results: </strong>The <i>r</i> <sup>2</sup> values observed in the <i>ex vivo</i> study were Tonovet (0.923), Tonovet Plus (0.925), Tono-Pen Avia Vet (0.877), and Kowa HA-2 (0.901). The IOP values in mmHg in the <i>in vivo</i> study were as follows: Manometer (16.1 ± 2.7), Tonovet (21.1 ± 3.6), Tonovet Plus (19.7 ± 7.2), Tono-Pen Avia Vet (17.6 ± 7.9), and Kowa HA-2 (16.8 ± 2.0). In the outpatient clinical study, the IOP values in mmHg were as follows: Tonovet (19.7 ± 6.6), Tonovet Plus (17.1 ± 5.4), Tono-Pen Avia Vet (16.3 ± 4.3), and Kowa HA-2 (14.5 ± 2.2).</p><p><strong>Conclusion: </strong>IOP and manometry readings were strongly correlated by all tonometers. In the clinical setting, the most and least IOP measurements were recorded using Tonovet and Kowa HA-2, respectively, stressing the importance of an IOP reference table for each tonometer in feline practice.</p>\",\"PeriodicalId\":23587,\"journal\":{\"name\":\"Veterinary World\",\"volume\":\"17 8\",\"pages\":\"1803-1809\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11422646/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary World\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14202/vetworld.2024.1803-1809\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/8/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"AGRICULTURE, DAIRY & ANIMAL SCIENCE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary World","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14202/vetworld.2024.1803-1809","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/20 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"AGRICULTURE, DAIRY & ANIMAL SCIENCE","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:测量眼压(IOP)对于识别眼睛中潜在的损害性变化(包括青光眼和葡萄膜炎)至关重要。本研究比较了使用 Tonovet 和 Tonovet Plus(回弹式)、Tono-Pen Avia Vet(applanation)和 Kowa HA-2(Goldman 方法学 applanation)眼压计对猫进行的眼压测量:一项体外实验(5 只猫的 10 只眼睛)将眼压计和眼压计的数值相关联,并确定相关系数 (r2);一项体内研究(5 只镇静猫的 10 只眼睛)将眼压计和眼压计的读数进行对比;一项门诊临床试验(45 只猫的 80 只眼睛)仅对眼压计的测量值进行分析:体内研究中观察到的 r 2 值分别为 Tonovet(0.923)、Tonovet Plus(0.925)、Tono-Pen Avia Vet(0.877)和 Kowa HA-2(0.901)。在体内研究中,以毫米汞柱为单位的眼压值如下:Manometer (16.1 ± 2.7)、Tonovet (21.1 ± 3.6)、Tonovet Plus (19.7 ± 7.2)、Tono-Pen Avia Vet (17.6 ± 7.9) 和 Kowa HA-2 (16.8 ± 2.0)。在门诊临床研究中,以毫米汞柱为单位的眼压值如下:Tonovet(19.7 ± 6.6)、Tonovet Plus(17.1 ± 5.4)、Tono-Pen Avia Vet(16.3 ± 4.3)和 Kowa HA-2(14.5 ± 2.2):结论:所有眼压计的眼压和测压读数都密切相关。在临床环境中,Tonovet 和 Kowa HA-2 分别记录了最多和最少的眼压测量值,这强调了为猫科动物使用的每种眼压计制定眼压参考表的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of three methodologies for measuring intraocular pressure in healthy cats.

Background and aim: Measuring intraocular pressure (IOP) is crucial for identifying potentially damaging changes in the eyes, including diseases as glaucoma and uveitis. This study compared intraocular pressure (IOP) measurements in cats using the Tonovet and Tonovet Plus (rebound), Tono-Pen Avia Vet (applanation), and Kowa HA-2 (Goldman's methodology applanation) tonometers.

Materials and methods: 55 healthy cats (108 eyes) were assessed through three distinct studies: An ex vivo experiment (10 eyes of five cats) to correlate IOP manometry and tonometry values and ascertain the correlation coefficient (r2); an in vivo study (10 eyes of five sedated cats) to contrast manometer and tonometer readings; and an outpatient clinical trial (80 eyes of 45 cats) to analyze only tonometer measurements.

Results: The r 2 values observed in the ex vivo study were Tonovet (0.923), Tonovet Plus (0.925), Tono-Pen Avia Vet (0.877), and Kowa HA-2 (0.901). The IOP values in mmHg in the in vivo study were as follows: Manometer (16.1 ± 2.7), Tonovet (21.1 ± 3.6), Tonovet Plus (19.7 ± 7.2), Tono-Pen Avia Vet (17.6 ± 7.9), and Kowa HA-2 (16.8 ± 2.0). In the outpatient clinical study, the IOP values in mmHg were as follows: Tonovet (19.7 ± 6.6), Tonovet Plus (17.1 ± 5.4), Tono-Pen Avia Vet (16.3 ± 4.3), and Kowa HA-2 (14.5 ± 2.2).

Conclusion: IOP and manometry readings were strongly correlated by all tonometers. In the clinical setting, the most and least IOP measurements were recorded using Tonovet and Kowa HA-2, respectively, stressing the importance of an IOP reference table for each tonometer in feline practice.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Veterinary World
Veterinary World Multiple-
CiteScore
3.60
自引率
12.50%
发文量
317
审稿时长
16 weeks
期刊介绍: Veterinary World publishes high quality papers focusing on Veterinary and Animal Science. The fields of study are bacteriology, parasitology, pathology, virology, immunology, mycology, public health, biotechnology, meat science, fish diseases, nutrition, gynecology, genetics, wildlife, laboratory animals, animal models of human infections, prion diseases and epidemiology. Studies on zoonotic and emerging infections are highly appreciated. Review articles are highly appreciated. All articles published by Veterinary World are made freely and permanently accessible online. All articles to Veterinary World are posted online immediately as they are ready for publication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信