睑板形态是否会影响白种人和亚洲人眼睛的泪液半月板高度?

IF 1.6 4区 医学 Q3 OPHTHALMOLOGY
Optometry and Vision Science Pub Date : 2024-09-01 Epub Date: 2024-10-01 DOI:10.1097/OPX.0000000000002180
Maëlys Guinel, Etty Bitton
{"title":"睑板形态是否会影响白种人和亚洲人眼睛的泪液半月板高度?","authors":"Maëlys Guinel, Etty Bitton","doi":"10.1097/OPX.0000000000002180","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The central lower TMH is used as a clinical measure of tear volume in the assessment of contact lens candidates and patients with dry eyes. Ethnic differences in eyelid morphology may influence the measurement of the TMH. Furthermore, with the advent of larger contact lenses, such as scleral lenses, it would be of clinical value to assess the TMH centrally and peripherally. The purpose of this study was to evaluate and compare the TMH at different positions along the palpebral margin between Caucasian and Asian eyes.</p><p><strong>Methods: </strong>This prospective study evaluated the lower TMH in five positions (central, temporal and nasal limbus and temporal and nasal periphery) of the right eye using the Keratograph 5M (Oculus) instrument in Caucasian and Asian participants between 10 am and 12 pm . The TMH at each position was taken three times and averaged and analyzed using a 5 × 2 repeated-measures analysis of variance.</p><p><strong>Results: </strong>Central TMH did not differ significantly ( F = 0.02, p=0.88) in Caucasians (n = 20, aged 24.45 [2.30] years, TMH 0.320 [0.052] mm) and Asians (n = 20, aged 22.25 [3.43] years, TMH 0.325 [0.048] mm). A difference was noted with respect to TMH positions along the lid margin ( F = 64.17, p<0.001), independent of ethnicity ( F = 2.15, p=0.15). A post hoc analysis revealed a significantly higher TMH temporally when compared with centrally or nasally (p<0.001).</p><p><strong>Conclusions: </strong>This study demonstrated the similarity of the central TMH and the differences in the peripheral TMH within Caucasian and Asian eyes. This may be clinically relevant when using the Tear Film & Ocular Surface Society Dry Eye Workshop II diagnostic algorithm for dry eyes and when fitting scleral contact lenses. Future studies need to consider that ethnic differences may exist for certain tests in order to personalize the care and management of each patient.</p>","PeriodicalId":19649,"journal":{"name":"Optometry and Vision Science","volume":" ","pages":"537-541"},"PeriodicalIF":1.6000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Does the palpebral morphology influence the tear meniscus height between Caucasian and Asian eyes?\",\"authors\":\"Maëlys Guinel, Etty Bitton\",\"doi\":\"10.1097/OPX.0000000000002180\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The central lower TMH is used as a clinical measure of tear volume in the assessment of contact lens candidates and patients with dry eyes. Ethnic differences in eyelid morphology may influence the measurement of the TMH. Furthermore, with the advent of larger contact lenses, such as scleral lenses, it would be of clinical value to assess the TMH centrally and peripherally. The purpose of this study was to evaluate and compare the TMH at different positions along the palpebral margin between Caucasian and Asian eyes.</p><p><strong>Methods: </strong>This prospective study evaluated the lower TMH in five positions (central, temporal and nasal limbus and temporal and nasal periphery) of the right eye using the Keratograph 5M (Oculus) instrument in Caucasian and Asian participants between 10 am and 12 pm . The TMH at each position was taken three times and averaged and analyzed using a 5 × 2 repeated-measures analysis of variance.</p><p><strong>Results: </strong>Central TMH did not differ significantly ( F = 0.02, p=0.88) in Caucasians (n = 20, aged 24.45 [2.30] years, TMH 0.320 [0.052] mm) and Asians (n = 20, aged 22.25 [3.43] years, TMH 0.325 [0.048] mm). A difference was noted with respect to TMH positions along the lid margin ( F = 64.17, p<0.001), independent of ethnicity ( F = 2.15, p=0.15). A post hoc analysis revealed a significantly higher TMH temporally when compared with centrally or nasally (p<0.001).</p><p><strong>Conclusions: </strong>This study demonstrated the similarity of the central TMH and the differences in the peripheral TMH within Caucasian and Asian eyes. This may be clinically relevant when using the Tear Film & Ocular Surface Society Dry Eye Workshop II diagnostic algorithm for dry eyes and when fitting scleral contact lenses. Future studies need to consider that ethnic differences may exist for certain tests in order to personalize the care and management of each patient.</p>\",\"PeriodicalId\":19649,\"journal\":{\"name\":\"Optometry and Vision Science\",\"volume\":\" \",\"pages\":\"537-541\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Optometry and Vision Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/OPX.0000000000002180\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optometry and Vision Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/OPX.0000000000002180","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:在对隐形眼镜配戴者和干眼症患者进行评估时,中央下TMH被用作泪液容量的临床测量指标。眼睑形态的种族差异可能会影响 TMH 的测量。此外,随着较大型隐形眼镜(如巩膜镜)的出现,从中央和外围评估泪液容积也具有临床价值。本研究的目的是评估和比较白种人和亚洲人眼睛在睑缘不同位置的 TMH:这项前瞻性研究使用 Keratograph 5M (Oculus) 仪器,在上午 10 点到晚上 12 点之间,对白种人和亚裔参与者右眼五个位置(中央、颞和鼻缘、颞和鼻周边)的 TMH 下限进行了评估。每个位置的 TMH 均测量三次,取平均值,并采用 5 × 2 重复测量方差分析法进行分析:白种人(n = 20,年龄 24.45 [2.30]岁,TMH 0.320 [0.052] mm)和亚洲人(n = 20,年龄 22.25 [3.43]岁,TMH 0.325 [0.048] mm)的中心 TMH 无明显差异(F = 0.02,p=0.88)。TMH 沿睑缘的位置存在差异(F = 64.17,p 结论:这项研究表明,白种人和亚洲人眼球中央 TMH 相似,而周边 TMH 存在差异。在使用泪膜与眼表学会干眼研讨会 II 干眼诊断算法和配戴巩膜接触镜时,这可能与临床相关。未来的研究需要考虑到某些检查可能存在的种族差异,以便对每位患者进行个性化护理和管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Does the palpebral morphology influence the tear meniscus height between Caucasian and Asian eyes?

Purpose: The central lower TMH is used as a clinical measure of tear volume in the assessment of contact lens candidates and patients with dry eyes. Ethnic differences in eyelid morphology may influence the measurement of the TMH. Furthermore, with the advent of larger contact lenses, such as scleral lenses, it would be of clinical value to assess the TMH centrally and peripherally. The purpose of this study was to evaluate and compare the TMH at different positions along the palpebral margin between Caucasian and Asian eyes.

Methods: This prospective study evaluated the lower TMH in five positions (central, temporal and nasal limbus and temporal and nasal periphery) of the right eye using the Keratograph 5M (Oculus) instrument in Caucasian and Asian participants between 10 am and 12 pm . The TMH at each position was taken three times and averaged and analyzed using a 5 × 2 repeated-measures analysis of variance.

Results: Central TMH did not differ significantly ( F = 0.02, p=0.88) in Caucasians (n = 20, aged 24.45 [2.30] years, TMH 0.320 [0.052] mm) and Asians (n = 20, aged 22.25 [3.43] years, TMH 0.325 [0.048] mm). A difference was noted with respect to TMH positions along the lid margin ( F = 64.17, p<0.001), independent of ethnicity ( F = 2.15, p=0.15). A post hoc analysis revealed a significantly higher TMH temporally when compared with centrally or nasally (p<0.001).

Conclusions: This study demonstrated the similarity of the central TMH and the differences in the peripheral TMH within Caucasian and Asian eyes. This may be clinically relevant when using the Tear Film & Ocular Surface Society Dry Eye Workshop II diagnostic algorithm for dry eyes and when fitting scleral contact lenses. Future studies need to consider that ethnic differences may exist for certain tests in order to personalize the care and management of each patient.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Optometry and Vision Science
Optometry and Vision Science 医学-眼科学
CiteScore
2.80
自引率
7.10%
发文量
210
审稿时长
3-6 weeks
期刊介绍: Optometry and Vision Science is the monthly peer-reviewed scientific publication of the American Academy of Optometry, publishing original research since 1924. Optometry and Vision Science is an internationally recognized source for education and information on current discoveries in optometry, physiological optics, vision science, and related fields. The journal considers original contributions that advance clinical practice, vision science, and public health. Authors should remember that the journal reaches readers worldwide and their submissions should be relevant and of interest to a broad audience. Topical priorities include, but are not limited to: clinical and laboratory research, evidence-based reviews, contact lenses, ocular growth and refractive error development, eye movements, visual function and perception, biology of the eye and ocular disease, epidemiology and public health, biomedical optics and instrumentation, novel and important clinical observations and treatments, and optometric education.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信