膈肌超声对颈脊髓损伤后呼吸机断流结果的预测价值:回顾性病例系列。

IF 2.1 4区 医学 Q2 ACOUSTICS
Natasha S. Bhatia MD, Stephany Kunzweiler PT, DPT, Christopher Conley RT, Ki H. Kim MD, Adenike A. Adewuyi MD, PhD, Antonio Mondriguez-Gonzalez MD, Lisa F. Wolfe MD, Mary Kwasny ScD, Colin K. Franz MD, PhD
{"title":"膈肌超声对颈脊髓损伤后呼吸机断流结果的预测价值:回顾性病例系列。","authors":"Natasha S. Bhatia MD,&nbsp;Stephany Kunzweiler PT, DPT,&nbsp;Christopher Conley RT,&nbsp;Ki H. Kim MD,&nbsp;Adenike A. Adewuyi MD, PhD,&nbsp;Antonio Mondriguez-Gonzalez MD,&nbsp;Lisa F. Wolfe MD,&nbsp;Mary Kwasny ScD,&nbsp;Colin K. Franz MD, PhD","doi":"10.1002/jum.16589","DOIUrl":null,"url":null,"abstract":"<div>\n \n <section>\n \n <h3> Objectives</h3>\n \n <p>Neuromuscular respiratory failure after cervical spinal cord injury (cSCI) can lead to dependence on an invasive mechanical ventilator. Ventilator-free breathing after cSCI is associated with improved morbidity, mortality, and quality of life. We investigated the use of diaphragm muscle ultrasound to predict ventilator weaning outcomes after cSCI.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>This is a retrospective case series conducted at a university-affiliated freestanding inpatient rehabilitation facility. We identified patients with cSCI who had a tracheostomy and were dependent on an invasive mechanical ventilator at the time of admission to inpatient rehabilitation. A diaphragm muscle ultrasound was performed, which included measurements of the thickness of the diaphragm and a calculation of the thickening ratio (TR), which reflects diaphragm muscle contraction. The primary outcome measure was the need for mechanical ventilation at time of discharge from the inpatient rehabilitation facility. Successful ventilator weaning was defined as either daytime or full 24-hour ventilator-free breathing.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Of the 21 patients enrolled, 11 (52%) were able to wean successfully (partially or fully) from the ventilator. Of the ultrasound measurements that were taken, the TR was the optimal predictor for ventilator weaning outcomes. A threshold of TR ≥ 1.2 as the maximum hemidiaphragm measurement had a sensitivity of 1.0 and specificity of 0.90 for predicting ventilator weaning.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Normal diaphragm contractility (TR ≥ 1.2) as determined by diaphragm muscle ultrasound is a strong positive predictor for successful ventilator weaning in patients with cSCI.</p>\n \n <p>Utilizing diaphragm ultrasound, rehabilitation physicians can set precision rehabilitation goals regarding ventilator weaning for inpatients with respiratory failure after cSCI, potentially improving both outcomes and quality of life.</p>\n </section>\n </div>","PeriodicalId":17563,"journal":{"name":"Journal of Ultrasound in Medicine","volume":"44 1","pages":"119-126"},"PeriodicalIF":2.1000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11632646/pdf/","citationCount":"0","resultStr":"{\"title\":\"Predictive Value of Diaphragm Muscle Ultrasound for Ventilator Weaning Outcomes After Cervical Spinal Cord Injury\",\"authors\":\"Natasha S. Bhatia MD,&nbsp;Stephany Kunzweiler PT, DPT,&nbsp;Christopher Conley RT,&nbsp;Ki H. Kim MD,&nbsp;Adenike A. Adewuyi MD, PhD,&nbsp;Antonio Mondriguez-Gonzalez MD,&nbsp;Lisa F. Wolfe MD,&nbsp;Mary Kwasny ScD,&nbsp;Colin K. Franz MD, PhD\",\"doi\":\"10.1002/jum.16589\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <section>\\n \\n <h3> Objectives</h3>\\n \\n <p>Neuromuscular respiratory failure after cervical spinal cord injury (cSCI) can lead to dependence on an invasive mechanical ventilator. Ventilator-free breathing after cSCI is associated with improved morbidity, mortality, and quality of life. We investigated the use of diaphragm muscle ultrasound to predict ventilator weaning outcomes after cSCI.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>This is a retrospective case series conducted at a university-affiliated freestanding inpatient rehabilitation facility. We identified patients with cSCI who had a tracheostomy and were dependent on an invasive mechanical ventilator at the time of admission to inpatient rehabilitation. A diaphragm muscle ultrasound was performed, which included measurements of the thickness of the diaphragm and a calculation of the thickening ratio (TR), which reflects diaphragm muscle contraction. The primary outcome measure was the need for mechanical ventilation at time of discharge from the inpatient rehabilitation facility. Successful ventilator weaning was defined as either daytime or full 24-hour ventilator-free breathing.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Of the 21 patients enrolled, 11 (52%) were able to wean successfully (partially or fully) from the ventilator. Of the ultrasound measurements that were taken, the TR was the optimal predictor for ventilator weaning outcomes. A threshold of TR ≥ 1.2 as the maximum hemidiaphragm measurement had a sensitivity of 1.0 and specificity of 0.90 for predicting ventilator weaning.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>Normal diaphragm contractility (TR ≥ 1.2) as determined by diaphragm muscle ultrasound is a strong positive predictor for successful ventilator weaning in patients with cSCI.</p>\\n \\n <p>Utilizing diaphragm ultrasound, rehabilitation physicians can set precision rehabilitation goals regarding ventilator weaning for inpatients with respiratory failure after cSCI, potentially improving both outcomes and quality of life.</p>\\n </section>\\n </div>\",\"PeriodicalId\":17563,\"journal\":{\"name\":\"Journal of Ultrasound in Medicine\",\"volume\":\"44 1\",\"pages\":\"119-126\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11632646/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ultrasound in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jum.16589\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound in Medicine","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jum.16589","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

摘要

目的:颈脊髓损伤(cSCI)后的神经肌肉呼吸衰竭可导致对有创机械呼吸机的依赖。颈脊髓损伤后无呼吸机呼吸与发病率、死亡率和生活质量的改善有关。我们研究了使用横膈膜肌肉超声波预测 cSCI 后呼吸机断流结果的方法:这是一项回顾性病例系列研究,在一所大学附属的独立住院康复机构进行。我们确定了入院康复治疗时使用气管造口术和有创机械呼吸机的 cSCI 患者。我们对患者的膈肌进行了超声检查,包括测量膈肌的厚度和计算反映膈肌收缩情况的增厚比(TR)。主要结果指标是患者从住院康复机构出院时对机械通气的需求。呼吸机断气成功的定义是白天或 24 小时完全无呼吸机呼吸:在 21 名入选患者中,有 11 人(52%)能够成功(部分或完全)断开呼吸机。在进行的超声测量中,TR 是预测呼吸机断奶结果的最佳指标。以TR≥1.2作为最大半膈测量值的阈值,预测呼吸机断奶的灵敏度为1.0,特异性为0.90:结论:膈肌超声确定的正常膈肌收缩力(TR ≥ 1.2)是 cSCI 患者成功断呼吸机的一个强有力的积极预测指标。利用膈肌超声,康复医师可以为 cSCI 后呼吸衰竭的住院患者制定精确的呼吸机断流康复目标,从而改善预后和生活质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Predictive Value of Diaphragm Muscle Ultrasound for Ventilator Weaning Outcomes After Cervical Spinal Cord Injury

Predictive Value of Diaphragm Muscle Ultrasound for Ventilator Weaning Outcomes After Cervical Spinal Cord Injury

Objectives

Neuromuscular respiratory failure after cervical spinal cord injury (cSCI) can lead to dependence on an invasive mechanical ventilator. Ventilator-free breathing after cSCI is associated with improved morbidity, mortality, and quality of life. We investigated the use of diaphragm muscle ultrasound to predict ventilator weaning outcomes after cSCI.

Methods

This is a retrospective case series conducted at a university-affiliated freestanding inpatient rehabilitation facility. We identified patients with cSCI who had a tracheostomy and were dependent on an invasive mechanical ventilator at the time of admission to inpatient rehabilitation. A diaphragm muscle ultrasound was performed, which included measurements of the thickness of the diaphragm and a calculation of the thickening ratio (TR), which reflects diaphragm muscle contraction. The primary outcome measure was the need for mechanical ventilation at time of discharge from the inpatient rehabilitation facility. Successful ventilator weaning was defined as either daytime or full 24-hour ventilator-free breathing.

Results

Of the 21 patients enrolled, 11 (52%) were able to wean successfully (partially or fully) from the ventilator. Of the ultrasound measurements that were taken, the TR was the optimal predictor for ventilator weaning outcomes. A threshold of TR ≥ 1.2 as the maximum hemidiaphragm measurement had a sensitivity of 1.0 and specificity of 0.90 for predicting ventilator weaning.

Conclusion

Normal diaphragm contractility (TR ≥ 1.2) as determined by diaphragm muscle ultrasound is a strong positive predictor for successful ventilator weaning in patients with cSCI.

Utilizing diaphragm ultrasound, rehabilitation physicians can set precision rehabilitation goals regarding ventilator weaning for inpatients with respiratory failure after cSCI, potentially improving both outcomes and quality of life.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
4.30%
发文量
205
审稿时长
1.5 months
期刊介绍: The Journal of Ultrasound in Medicine (JUM) is dedicated to the rapid, accurate publication of original articles dealing with all aspects of medical ultrasound, particularly its direct application to patient care but also relevant basic science, advances in instrumentation, and biological effects. The journal is an official publication of the American Institute of Ultrasound in Medicine and publishes articles in a variety of categories, including Original Research papers, Review Articles, Pictorial Essays, Technical Innovations, Case Series, Letters to the Editor, and more, from an international bevy of countries in a continual effort to showcase and promote advances in the ultrasound community. Represented through these efforts are a wide variety of disciplines of ultrasound, including, but not limited to: -Basic Science- Breast Ultrasound- Contrast-Enhanced Ultrasound- Dermatology- Echocardiography- Elastography- Emergency Medicine- Fetal Echocardiography- Gastrointestinal Ultrasound- General and Abdominal Ultrasound- Genitourinary Ultrasound- Gynecologic Ultrasound- Head and Neck Ultrasound- High Frequency Clinical and Preclinical Imaging- Interventional-Intraoperative Ultrasound- Musculoskeletal Ultrasound- Neurosonology- Obstetric Ultrasound- Ophthalmologic Ultrasound- Pediatric Ultrasound- Point-of-Care Ultrasound- Public Policy- Superficial Structures- Therapeutic Ultrasound- Ultrasound Education- Ultrasound in Global Health- Urologic Ultrasound- Vascular Ultrasound
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信