Qiuxiang Chen MD, Luyao Jia MD, Shiya Wang MD, Menghua Chen MD, Chan Zhang MD, Yue Fang MD, Meifang Deng MD, Chunchun Jin MD
{"title":"道格拉斯袋液提高了经阴道超声诊断子宫骶骨韧带深部浸润性子宫内膜异位症的准确性:一项前瞻性研究","authors":"Qiuxiang Chen MD, Luyao Jia MD, Shiya Wang MD, Menghua Chen MD, Chan Zhang MD, Yue Fang MD, Meifang Deng MD, Chunchun Jin MD","doi":"10.1002/jum.16586","DOIUrl":null,"url":null,"abstract":"<div>\n \n <section>\n \n <h3> Objectives</h3>\n \n <p>To compare the accuracy of transvaginal ultrasound (TVUS) with laparoscopy in detecting and characterizing uterosacral ligament (USL) nodules of deep infiltrative endometriosis (DIE) between patients with and without pouch of Douglas (POD) fluid.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>This prospective study was conducted between June 2021 and July 2023. We included patients from the Second People's Hospital of Shenzhen with two TVUS tests: no POD fluid on the first TVUS test and POD fluid on the second TVUS test. POD fluid was obtained in two ways: naturally occurring fluid during the luteal phase of the menstrual cycle and SonoPODography. Laparoscopic results are the gold standard. To compare the diagnostic performance of TVUS in the diagnosis of DIE on USLs with and without POD fluid.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>We included 42 patients with a mean age of 36.4 ± 5.4 years. The maximum length diameter for DIE nodules on USLs with and without POD fluid was 13.3 ± 3.3 mm and 10.2 ± 2.5 mm (<i>P</i> < .001), respectively, while the depth of infiltration was 8.1 ± 2.4 mm and 6.1 ± 1.4 mm (<i>P</i> < .001), respectively. When compared to laparoscopic findings, TVUS findings with and without POD fluid resulted in a sensitivity, specificity, accuracy, positive predictive value, negative predictive value area under the curve, and Cohen kappa of 92.3%, 93.8%, 92.9%, 96.0%, 88.2%, 0.930, and 0.850 and 61.5%, 93.8%, 73.8%, 94.1%, 50.0%, 0.766, and 0.499, respectively. Laparoscopy showed USL involvement in up to 59.5% of patients. With or without fluid, the most common ultrasound features of DIE lesions were USL thickening, irregular morphology, clear boundaries, low echo, and no blood flow signal.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>For patients with clinical suspicion of DIE, TVUS with POD fluid has a higher accuracy for diagnosing USL DIE than TVUS without POD fluid.</p>\n </section>\n </div>","PeriodicalId":17563,"journal":{"name":"Journal of Ultrasound in Medicine","volume":"44 1","pages":"111-117"},"PeriodicalIF":2.1000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Douglas Pouch Fluid Improves the Accuracy of Transvaginal Ultrasound in the Diagnosis of Uterosacral Ligaments Deep Infiltration Endometriosis\",\"authors\":\"Qiuxiang Chen MD, Luyao Jia MD, Shiya Wang MD, Menghua Chen MD, Chan Zhang MD, Yue Fang MD, Meifang Deng MD, Chunchun Jin MD\",\"doi\":\"10.1002/jum.16586\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n <section>\\n \\n <h3> Objectives</h3>\\n \\n <p>To compare the accuracy of transvaginal ultrasound (TVUS) with laparoscopy in detecting and characterizing uterosacral ligament (USL) nodules of deep infiltrative endometriosis (DIE) between patients with and without pouch of Douglas (POD) fluid.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>This prospective study was conducted between June 2021 and July 2023. We included patients from the Second People's Hospital of Shenzhen with two TVUS tests: no POD fluid on the first TVUS test and POD fluid on the second TVUS test. POD fluid was obtained in two ways: naturally occurring fluid during the luteal phase of the menstrual cycle and SonoPODography. Laparoscopic results are the gold standard. To compare the diagnostic performance of TVUS in the diagnosis of DIE on USLs with and without POD fluid.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>We included 42 patients with a mean age of 36.4 ± 5.4 years. The maximum length diameter for DIE nodules on USLs with and without POD fluid was 13.3 ± 3.3 mm and 10.2 ± 2.5 mm (<i>P</i> < .001), respectively, while the depth of infiltration was 8.1 ± 2.4 mm and 6.1 ± 1.4 mm (<i>P</i> < .001), respectively. When compared to laparoscopic findings, TVUS findings with and without POD fluid resulted in a sensitivity, specificity, accuracy, positive predictive value, negative predictive value area under the curve, and Cohen kappa of 92.3%, 93.8%, 92.9%, 96.0%, 88.2%, 0.930, and 0.850 and 61.5%, 93.8%, 73.8%, 94.1%, 50.0%, 0.766, and 0.499, respectively. Laparoscopy showed USL involvement in up to 59.5% of patients. With or without fluid, the most common ultrasound features of DIE lesions were USL thickening, irregular morphology, clear boundaries, low echo, and no blood flow signal.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>For patients with clinical suspicion of DIE, TVUS with POD fluid has a higher accuracy for diagnosing USL DIE than TVUS without POD fluid.</p>\\n </section>\\n </div>\",\"PeriodicalId\":17563,\"journal\":{\"name\":\"Journal of Ultrasound in Medicine\",\"volume\":\"44 1\",\"pages\":\"111-117\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ultrasound in Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jum.16586\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound in Medicine","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jum.16586","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0
摘要
研究目的比较经阴道超声(TVUS)与腹腔镜在有和无道格拉斯袋(POD)积液的子宫深部浸润性子宫内膜异位症(DIE)患者子宫骶韧带(USL)结节的检测和定性方面的准确性:这项前瞻性研究在2021年6月至2023年7月期间进行。我们纳入了深圳市第二人民医院进行两次 TVUS 检查的患者:第一次 TVUS 检查无 POD 液,第二次 TVUS 检查有 POD 液。POD液通过两种方式获得:月经周期黄体期自然产生的液体和SonoPOD造影。腹腔镜检查结果是金标准。比较 TVUS 在诊断有 POD 液和无 POD 液的 USL 上的 DIE 时的诊断性能:我们共纳入 42 名患者,平均年龄(36.4 ± 5.4)岁。USL上有POD液和无POD液的DIE结节的最大长度直径分别为(13.3±3.3)毫米和(10.2±2.5)毫米(P对于临床怀疑有 DIE 的患者,与无 POD 液的 TVUS 相比,有 POD 液的 TVUS 诊断 USL DIE 的准确率更高。
Douglas Pouch Fluid Improves the Accuracy of Transvaginal Ultrasound in the Diagnosis of Uterosacral Ligaments Deep Infiltration Endometriosis
Objectives
To compare the accuracy of transvaginal ultrasound (TVUS) with laparoscopy in detecting and characterizing uterosacral ligament (USL) nodules of deep infiltrative endometriosis (DIE) between patients with and without pouch of Douglas (POD) fluid.
Methods
This prospective study was conducted between June 2021 and July 2023. We included patients from the Second People's Hospital of Shenzhen with two TVUS tests: no POD fluid on the first TVUS test and POD fluid on the second TVUS test. POD fluid was obtained in two ways: naturally occurring fluid during the luteal phase of the menstrual cycle and SonoPODography. Laparoscopic results are the gold standard. To compare the diagnostic performance of TVUS in the diagnosis of DIE on USLs with and without POD fluid.
Results
We included 42 patients with a mean age of 36.4 ± 5.4 years. The maximum length diameter for DIE nodules on USLs with and without POD fluid was 13.3 ± 3.3 mm and 10.2 ± 2.5 mm (P < .001), respectively, while the depth of infiltration was 8.1 ± 2.4 mm and 6.1 ± 1.4 mm (P < .001), respectively. When compared to laparoscopic findings, TVUS findings with and without POD fluid resulted in a sensitivity, specificity, accuracy, positive predictive value, negative predictive value area under the curve, and Cohen kappa of 92.3%, 93.8%, 92.9%, 96.0%, 88.2%, 0.930, and 0.850 and 61.5%, 93.8%, 73.8%, 94.1%, 50.0%, 0.766, and 0.499, respectively. Laparoscopy showed USL involvement in up to 59.5% of patients. With or without fluid, the most common ultrasound features of DIE lesions were USL thickening, irregular morphology, clear boundaries, low echo, and no blood flow signal.
Conclusions
For patients with clinical suspicion of DIE, TVUS with POD fluid has a higher accuracy for diagnosing USL DIE than TVUS without POD fluid.
期刊介绍:
The Journal of Ultrasound in Medicine (JUM) is dedicated to the rapid, accurate publication of original articles dealing with all aspects of medical ultrasound, particularly its direct application to patient care but also relevant basic science, advances in instrumentation, and biological effects. The journal is an official publication of the American Institute of Ultrasound in Medicine and publishes articles in a variety of categories, including Original Research papers, Review Articles, Pictorial Essays, Technical Innovations, Case Series, Letters to the Editor, and more, from an international bevy of countries in a continual effort to showcase and promote advances in the ultrasound community.
Represented through these efforts are a wide variety of disciplines of ultrasound, including, but not limited to:
-Basic Science-
Breast Ultrasound-
Contrast-Enhanced Ultrasound-
Dermatology-
Echocardiography-
Elastography-
Emergency Medicine-
Fetal Echocardiography-
Gastrointestinal Ultrasound-
General and Abdominal Ultrasound-
Genitourinary Ultrasound-
Gynecologic Ultrasound-
Head and Neck Ultrasound-
High Frequency Clinical and Preclinical Imaging-
Interventional-Intraoperative Ultrasound-
Musculoskeletal Ultrasound-
Neurosonology-
Obstetric Ultrasound-
Ophthalmologic Ultrasound-
Pediatric Ultrasound-
Point-of-Care Ultrasound-
Public Policy-
Superficial Structures-
Therapeutic Ultrasound-
Ultrasound Education-
Ultrasound in Global Health-
Urologic Ultrasound-
Vascular Ultrasound