模拟口内调整对梯度多层整体氧化锆颜色和透明度的影响。

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Prosthetic Dentistry Pub Date : 2024-12-01 Epub Date: 2024-09-26 DOI:10.1016/j.prosdent.2024.08.025
Reham Ghanem, Ahmed Adel, Walid Al-Zordk
{"title":"模拟口内调整对梯度多层整体氧化锆颜色和透明度的影响。","authors":"Reham Ghanem, Ahmed Adel, Walid Al-Zordk","doi":"10.1016/j.prosdent.2024.08.025","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>The use of multilayered monolithic zirconia ceramics is becoming popular because it simplifies the production of esthetic restorations. The effect of clinical adjustment on the optical properties of these ceramics, especially strength-gradient zirconia, remains unclear.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to evaluate the color and translucency of gradient multilayered zirconia brands after grinding and polishing.</p><p><strong>Material and methods: </strong>Sixty 10×10×1-mm monolithic zirconia specimens were milled from 6 zirconia brands (Ceramill Zolid HT White, Ceramill Zolid HT Preshade, Ceramill Zolid FX Multicolor, VITA YZ XT Multicolor, IPS e.max ZirCAD Prime, and KATANA YML). The zirconia specimens were milled to include all layers of A2 preshaded multilayered zirconia blanks (A2 shade) except Ceramill Zolid HT White and Ceramill Zolid HT Preshade. Ceramill Zolid HT White specimens were milled from a white zirconia blank with subsequent shading. The color coordinates and the relative translucency parameter after glazing and after grinding and polishing were determined with a reflectance spectrophotometer, and the relative translucency parameter and contrast ratio were measured. The differences in color and translucency were calculated. The data were analyzed using 2-way ANOVA and 1-way ANOVA tests followed by the post hoc Tukey test (α=.05).</p><p><strong>Results: </strong>Statistically significant changes (P<.001) in the color coordinates measured before and after grinding and polishing were detected for each zirconia brand except for the KATANA YML that showed no significant difference (P=.686) in lightness. The highest color difference after grinding and polishing was detected in group KATANA YML. The 2-way ANOVA test showed a statistically significant interaction (P<.001) between the zirconia brand and the grinding and polishing regarding the relative translucency parameter. The zirconia brand had a significant impact on the relative translucency parameter before and after grinding and polishing (both P<.001).</p><p><strong>Conclusions: </strong>Except for KATANA YML, the color change in multilayered zirconia after clinical adjustment with polishing was not beyond the clinically acceptable limit of the color difference. Although clinical adjustment with polishing reduced the translucency of gradient zirconia, the change in translucency was below the clinically detectable threshold value of the translucency difference.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":"1313.e1-1313.e8"},"PeriodicalIF":4.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of simulated intraoral adjustment on the color and translucency of gradient multilayered monolithic zirconia.\",\"authors\":\"Reham Ghanem, Ahmed Adel, Walid Al-Zordk\",\"doi\":\"10.1016/j.prosdent.2024.08.025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Statement of problem: </strong>The use of multilayered monolithic zirconia ceramics is becoming popular because it simplifies the production of esthetic restorations. The effect of clinical adjustment on the optical properties of these ceramics, especially strength-gradient zirconia, remains unclear.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to evaluate the color and translucency of gradient multilayered zirconia brands after grinding and polishing.</p><p><strong>Material and methods: </strong>Sixty 10×10×1-mm monolithic zirconia specimens were milled from 6 zirconia brands (Ceramill Zolid HT White, Ceramill Zolid HT Preshade, Ceramill Zolid FX Multicolor, VITA YZ XT Multicolor, IPS e.max ZirCAD Prime, and KATANA YML). The zirconia specimens were milled to include all layers of A2 preshaded multilayered zirconia blanks (A2 shade) except Ceramill Zolid HT White and Ceramill Zolid HT Preshade. Ceramill Zolid HT White specimens were milled from a white zirconia blank with subsequent shading. The color coordinates and the relative translucency parameter after glazing and after grinding and polishing were determined with a reflectance spectrophotometer, and the relative translucency parameter and contrast ratio were measured. The differences in color and translucency were calculated. The data were analyzed using 2-way ANOVA and 1-way ANOVA tests followed by the post hoc Tukey test (α=.05).</p><p><strong>Results: </strong>Statistically significant changes (P<.001) in the color coordinates measured before and after grinding and polishing were detected for each zirconia brand except for the KATANA YML that showed no significant difference (P=.686) in lightness. The highest color difference after grinding and polishing was detected in group KATANA YML. The 2-way ANOVA test showed a statistically significant interaction (P<.001) between the zirconia brand and the grinding and polishing regarding the relative translucency parameter. The zirconia brand had a significant impact on the relative translucency parameter before and after grinding and polishing (both P<.001).</p><p><strong>Conclusions: </strong>Except for KATANA YML, the color change in multilayered zirconia after clinical adjustment with polishing was not beyond the clinically acceptable limit of the color difference. Although clinical adjustment with polishing reduced the translucency of gradient zirconia, the change in translucency was below the clinically detectable threshold value of the translucency difference.</p>\",\"PeriodicalId\":16866,\"journal\":{\"name\":\"Journal of Prosthetic Dentistry\",\"volume\":\" \",\"pages\":\"1313.e1-1313.e8\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthetic Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.prosdent.2024.08.025\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2024.08.025","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

问题陈述:多层整体氧化锆陶瓷的使用正变得越来越流行,因为它简化了美学修复体的制作。目的:本体外研究的目的是评估研磨和抛光后梯度多层氧化锆品牌的颜色和半透明度:从 6 种氧化锆品牌(Ceramill Zolid HT White、Ceramill Zolid HT Preshade、Ceramill Zolid FX Multicolor、VITA YZ XT Multicolor、IPS e.max ZirCAD Prime 和 KATANA YML)中研磨出 60 个 10×10×1 mm 的单片氧化锆试样。除 Ceramill Zolid HT White 和 Ceramill Zolid HT Preshade 外,氧化锆试样的研磨包括 A2 预着色多层氧化锆坯料(A2 着色)的所有层。Ceramill Zolid HT White 试样是由白色氧化锆坯料研磨而成,随后进行了着色。用反射分光光度计测定了上釉后和研磨抛光后的色坐标和相对半透明参数,并测量了相对半透明参数和对比度。计算颜色和半透明度的差异。数据分析采用 2 向方差分析和 1 向方差分析,然后进行事后 Tukey 检验(α=.05):统计意义上的重大变化(PC结论:除KATANA YML外,多层氧化锆在经过抛光临床调整后的颜色变化未超出临床可接受的色差范围。虽然通过抛光进行临床调整降低了梯度氧化锆的半透明度,但半透明度的变化低于临床可检测的半透明度差异阈值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of simulated intraoral adjustment on the color and translucency of gradient multilayered monolithic zirconia.

Statement of problem: The use of multilayered monolithic zirconia ceramics is becoming popular because it simplifies the production of esthetic restorations. The effect of clinical adjustment on the optical properties of these ceramics, especially strength-gradient zirconia, remains unclear.

Purpose: The purpose of this in vitro study was to evaluate the color and translucency of gradient multilayered zirconia brands after grinding and polishing.

Material and methods: Sixty 10×10×1-mm monolithic zirconia specimens were milled from 6 zirconia brands (Ceramill Zolid HT White, Ceramill Zolid HT Preshade, Ceramill Zolid FX Multicolor, VITA YZ XT Multicolor, IPS e.max ZirCAD Prime, and KATANA YML). The zirconia specimens were milled to include all layers of A2 preshaded multilayered zirconia blanks (A2 shade) except Ceramill Zolid HT White and Ceramill Zolid HT Preshade. Ceramill Zolid HT White specimens were milled from a white zirconia blank with subsequent shading. The color coordinates and the relative translucency parameter after glazing and after grinding and polishing were determined with a reflectance spectrophotometer, and the relative translucency parameter and contrast ratio were measured. The differences in color and translucency were calculated. The data were analyzed using 2-way ANOVA and 1-way ANOVA tests followed by the post hoc Tukey test (α=.05).

Results: Statistically significant changes (P<.001) in the color coordinates measured before and after grinding and polishing were detected for each zirconia brand except for the KATANA YML that showed no significant difference (P=.686) in lightness. The highest color difference after grinding and polishing was detected in group KATANA YML. The 2-way ANOVA test showed a statistically significant interaction (P<.001) between the zirconia brand and the grinding and polishing regarding the relative translucency parameter. The zirconia brand had a significant impact on the relative translucency parameter before and after grinding and polishing (both P<.001).

Conclusions: Except for KATANA YML, the color change in multilayered zirconia after clinical adjustment with polishing was not beyond the clinically acceptable limit of the color difference. Although clinical adjustment with polishing reduced the translucency of gradient zirconia, the change in translucency was below the clinically detectable threshold value of the translucency difference.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信