Kelsey R Tieken, Ka-Chun Siu, Jihyun Ma, Anthony Murante, Tiffany N Tanner, Vishal M Kothari, Ivy N Haskins
{"title":"腹腔镜腹股沟疝修补术和机器人腹股沟疝修补术在网片放置和网片固定方面的人体工程学差异。","authors":"Kelsey R Tieken, Ka-Chun Siu, Jihyun Ma, Anthony Murante, Tiffany N Tanner, Vishal M Kothari, Ivy N Haskins","doi":"10.1007/s10029-024-03168-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>General differences in surgeon ergonomics between laparoscopic and robotic-assisted inguinal hernia repairs (LIHR vs. RIHR) have been previously studied. However, specific differences in the ergonomics of mesh placement (MP) and mesh fixation (MF) are undetermined. Our aim was to determine if there are differences in the ergonomics of MP and MF between the surgical approaches. We hypothesize that we will identify differences, with the potential for worse ergonomics during LIHR.</p><p><strong>Methods: </strong>Data was collected from fifteen LIHR and fifteen RIHR. All cases were elective, primary inguinal hernias completed by a fellowship-trained minimally invasive surgeon. Surface electromyography (EMG) of four upper extremity muscle groups, including the upper trapezius (UT), anterior deltoid (AD), flexor carpi radialis (FCR) and extensor digitorum (ED), was recorded bilaterally during MP and MF. Muscle activation as a percent of maximum voluntary contraction (%MVC<sub>RMS</sub>) and muscle fatigue denoted as the median frequency of muscle activations (Fmed) were calculated for each muscle.</p><p><strong>Results: </strong>EMG analysis showed increased %MVC<sub>RMS</sub> in LIHR compared to RIHR cases, with significant findings in the left UT, right UT, ED, and FCR for MP and MF and the left FCR during MP. Muscle fatigue was decreased in LIHR compared to RIHR cases, with significant differences in left FCR and right ED and AD.</p><p><strong>Conclusion: </strong>Despite greater muscle activations during LIHR, RIHR had greater muscle fatigue. It is possible that short periods of high muscle activation are ergonomically protective during minimally invasive inguinal hernia repair. Identifying these differences may aid in development of procedure-specific interventions to improve ergonomics.</p>","PeriodicalId":13168,"journal":{"name":"Hernia","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ergonomic differences in mesh placement and mesh fixation between laparoscopic and robotic inguinal hernia repair with mesh.\",\"authors\":\"Kelsey R Tieken, Ka-Chun Siu, Jihyun Ma, Anthony Murante, Tiffany N Tanner, Vishal M Kothari, Ivy N Haskins\",\"doi\":\"10.1007/s10029-024-03168-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>General differences in surgeon ergonomics between laparoscopic and robotic-assisted inguinal hernia repairs (LIHR vs. RIHR) have been previously studied. However, specific differences in the ergonomics of mesh placement (MP) and mesh fixation (MF) are undetermined. Our aim was to determine if there are differences in the ergonomics of MP and MF between the surgical approaches. We hypothesize that we will identify differences, with the potential for worse ergonomics during LIHR.</p><p><strong>Methods: </strong>Data was collected from fifteen LIHR and fifteen RIHR. All cases were elective, primary inguinal hernias completed by a fellowship-trained minimally invasive surgeon. Surface electromyography (EMG) of four upper extremity muscle groups, including the upper trapezius (UT), anterior deltoid (AD), flexor carpi radialis (FCR) and extensor digitorum (ED), was recorded bilaterally during MP and MF. Muscle activation as a percent of maximum voluntary contraction (%MVC<sub>RMS</sub>) and muscle fatigue denoted as the median frequency of muscle activations (Fmed) were calculated for each muscle.</p><p><strong>Results: </strong>EMG analysis showed increased %MVC<sub>RMS</sub> in LIHR compared to RIHR cases, with significant findings in the left UT, right UT, ED, and FCR for MP and MF and the left FCR during MP. Muscle fatigue was decreased in LIHR compared to RIHR cases, with significant differences in left FCR and right ED and AD.</p><p><strong>Conclusion: </strong>Despite greater muscle activations during LIHR, RIHR had greater muscle fatigue. It is possible that short periods of high muscle activation are ergonomically protective during minimally invasive inguinal hernia repair. Identifying these differences may aid in development of procedure-specific interventions to improve ergonomics.</p>\",\"PeriodicalId\":13168,\"journal\":{\"name\":\"Hernia\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hernia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10029-024-03168-9\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/10/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hernia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10029-024-03168-9","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
Ergonomic differences in mesh placement and mesh fixation between laparoscopic and robotic inguinal hernia repair with mesh.
Purpose: General differences in surgeon ergonomics between laparoscopic and robotic-assisted inguinal hernia repairs (LIHR vs. RIHR) have been previously studied. However, specific differences in the ergonomics of mesh placement (MP) and mesh fixation (MF) are undetermined. Our aim was to determine if there are differences in the ergonomics of MP and MF between the surgical approaches. We hypothesize that we will identify differences, with the potential for worse ergonomics during LIHR.
Methods: Data was collected from fifteen LIHR and fifteen RIHR. All cases were elective, primary inguinal hernias completed by a fellowship-trained minimally invasive surgeon. Surface electromyography (EMG) of four upper extremity muscle groups, including the upper trapezius (UT), anterior deltoid (AD), flexor carpi radialis (FCR) and extensor digitorum (ED), was recorded bilaterally during MP and MF. Muscle activation as a percent of maximum voluntary contraction (%MVCRMS) and muscle fatigue denoted as the median frequency of muscle activations (Fmed) were calculated for each muscle.
Results: EMG analysis showed increased %MVCRMS in LIHR compared to RIHR cases, with significant findings in the left UT, right UT, ED, and FCR for MP and MF and the left FCR during MP. Muscle fatigue was decreased in LIHR compared to RIHR cases, with significant differences in left FCR and right ED and AD.
Conclusion: Despite greater muscle activations during LIHR, RIHR had greater muscle fatigue. It is possible that short periods of high muscle activation are ergonomically protective during minimally invasive inguinal hernia repair. Identifying these differences may aid in development of procedure-specific interventions to improve ergonomics.
期刊介绍:
Hernia was founded in 1997 by Jean P. Chevrel with the purpose of promoting clinical studies and basic research as they apply to groin hernias and the abdominal wall . Since that time, a true revolution in the field of hernia studies has transformed the field from a ”simple” disease to one that is very specialized. While the majority of surgeries for primary inguinal and abdominal wall hernia are performed in hospitals worldwide, complex situations such as multi recurrences, complications, abdominal wall reconstructions and others are being studied and treated in specialist centers. As a result, major institutions and societies are creating specific parameters and criteria to better address the complexities of hernia surgery.
Hernia is a journal written by surgeons who have made abdominal wall surgery their specific field of interest, but we will consider publishing content from any surgeon who wishes to improve the science of this field. The Journal aims to ensure that hernia surgery is safer and easier for surgeons as well as patients, and provides a forum to all surgeons in the exchange of new ideas, results, and important research that is the basis of professional activity.