直接冠修复材料对牙髓治疗过的前臼齿抗折性的影响:体外研究

IF 2.5 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Georgiana Florentina Gheorghe, Ana Maria Cristina Țâncu, Oana Elena Amza, Ioana Suciu, Laura Iosif, Stanca Cuc, Ioan Petean, Marioara Moldovan, Bogdan Dimitriu
{"title":"直接冠修复材料对牙髓治疗过的前臼齿抗折性的影响:体外研究","authors":"Georgiana Florentina Gheorghe, Ana Maria Cristina Țâncu, Oana Elena Amza, Ioana Suciu, Laura Iosif, Stanca Cuc, Ioan Petean, Marioara Moldovan, Bogdan Dimitriu","doi":"10.3390/dj12090294","DOIUrl":null,"url":null,"abstract":"<p><p>(1) Background: The long-term survival of an endodontically treated tooth depends on a successful root canal treatment as well as an adequate definitive coronal restoration. This study aimed to evaluate the strength of endodontically treated premolars with mesial-occlusal-distal (MOD) cavity preparation restored with different direct coronal restoration materials but from the same manufacturer against fracture. (2) Methods: sixty intact premolars were selected and placed into five groups (n = 12): G1-intact teeth, G2-endodontic treatment and unrestored MOD cavities, G3-endodontic treatment and MOD cavities restored with Tetric PowerFlow and Tetric EvoCeram, G4-endodontic treatment and MOD cavities restored with Multicore Flow and Tetric EvoCeram, and G5-endodontic treatment and MOD cavities restored with Multicore Flow. The specimens were subjected to an axial compression load at a speed of 1.6 mm/min and optically inspected before and after with a stereomicroscope. For each premolars group, the following data were recorded: the compression resistance, the compressive strength, and the maximum force supported. The microstructure of the samples after the compression test was analyzed using scanning electron microscopy (SEM). (3) Results: statistical analysis (ANOVA and Tukey test) showed that there was a statistically significant difference between G1 and the other groups. Even though there was no statistically significant difference between the restored groups, a better mechanical behavior was registered within the G3. (4) Conclusions: this in vitro study indicated that none of the materials used can lead to a higher or at least similar fracture resistance as the intact teeth. The coronal restoration only with nano-hybrid composites may lead to a higher therapeutic benefit for the fracture-susceptible premolars.</p>","PeriodicalId":11269,"journal":{"name":"Dentistry Journal","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11430839/pdf/","citationCount":"0","resultStr":"{\"title\":\"Influence of Direct Coronal Restoration Materials on the Fracture Resistance of Endodontically Treated Premolars: An In Vitro Study.\",\"authors\":\"Georgiana Florentina Gheorghe, Ana Maria Cristina Țâncu, Oana Elena Amza, Ioana Suciu, Laura Iosif, Stanca Cuc, Ioan Petean, Marioara Moldovan, Bogdan Dimitriu\",\"doi\":\"10.3390/dj12090294\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>(1) Background: The long-term survival of an endodontically treated tooth depends on a successful root canal treatment as well as an adequate definitive coronal restoration. This study aimed to evaluate the strength of endodontically treated premolars with mesial-occlusal-distal (MOD) cavity preparation restored with different direct coronal restoration materials but from the same manufacturer against fracture. (2) Methods: sixty intact premolars were selected and placed into five groups (n = 12): G1-intact teeth, G2-endodontic treatment and unrestored MOD cavities, G3-endodontic treatment and MOD cavities restored with Tetric PowerFlow and Tetric EvoCeram, G4-endodontic treatment and MOD cavities restored with Multicore Flow and Tetric EvoCeram, and G5-endodontic treatment and MOD cavities restored with Multicore Flow. The specimens were subjected to an axial compression load at a speed of 1.6 mm/min and optically inspected before and after with a stereomicroscope. For each premolars group, the following data were recorded: the compression resistance, the compressive strength, and the maximum force supported. The microstructure of the samples after the compression test was analyzed using scanning electron microscopy (SEM). (3) Results: statistical analysis (ANOVA and Tukey test) showed that there was a statistically significant difference between G1 and the other groups. Even though there was no statistically significant difference between the restored groups, a better mechanical behavior was registered within the G3. (4) Conclusions: this in vitro study indicated that none of the materials used can lead to a higher or at least similar fracture resistance as the intact teeth. The coronal restoration only with nano-hybrid composites may lead to a higher therapeutic benefit for the fracture-susceptible premolars.</p>\",\"PeriodicalId\":11269,\"journal\":{\"name\":\"Dentistry Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11430839/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dentistry Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/dj12090294\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj12090294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

(1) 背景:根管治疗后牙齿的长期存活取决于成功的根管治疗和适当的最终冠修复。本研究旨在评估经根管治疗的前磨牙的中-颊-远侧(MOD)牙洞预备,使用不同的直接冠修复材料(但来自同一制造商)修复后的抗折强度。(2) 方法:选择 60 颗完整的前臼齿,将其分为五组(n = 12):G1-无牙、G2-牙髓治疗和未修复的 MOD 牙洞、G3-牙髓治疗和使用 Tetric PowerFlow 和 Tetric EvoCeram 修复的 MOD 牙洞、G4-牙髓治疗和使用 Multicore Flow 和 Tetric EvoCeram 修复的 MOD 牙洞,以及 G5-牙髓治疗和使用 Multicore Flow 修复的 MOD 牙洞。以 1.6 毫米/分钟的速度对试样施加轴向压缩载荷,并在前后用体视显微镜进行光学检测。记录每组前臼齿的以下数据:抗压性、抗压强度和最大支撑力。使用扫描电子显微镜(SEM)分析了压缩试验后样品的微观结构。 (3) 结果:统计分析(方差分析和 Tukey 检验)表明,G1 组与其他组之间存在显著的统计学差异。尽管修复组之间没有明显的统计学差异,但 G3 组的机械性能更好。(4) 结论:这项体外研究表明,所使用的材料都不能使牙齿具有更高或至少类似于完整牙齿的抗折性。仅使用纳米杂化复合材料进行冠修复可能会为易折前臼齿带来更高的治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of Direct Coronal Restoration Materials on the Fracture Resistance of Endodontically Treated Premolars: An In Vitro Study.

(1) Background: The long-term survival of an endodontically treated tooth depends on a successful root canal treatment as well as an adequate definitive coronal restoration. This study aimed to evaluate the strength of endodontically treated premolars with mesial-occlusal-distal (MOD) cavity preparation restored with different direct coronal restoration materials but from the same manufacturer against fracture. (2) Methods: sixty intact premolars were selected and placed into five groups (n = 12): G1-intact teeth, G2-endodontic treatment and unrestored MOD cavities, G3-endodontic treatment and MOD cavities restored with Tetric PowerFlow and Tetric EvoCeram, G4-endodontic treatment and MOD cavities restored with Multicore Flow and Tetric EvoCeram, and G5-endodontic treatment and MOD cavities restored with Multicore Flow. The specimens were subjected to an axial compression load at a speed of 1.6 mm/min and optically inspected before and after with a stereomicroscope. For each premolars group, the following data were recorded: the compression resistance, the compressive strength, and the maximum force supported. The microstructure of the samples after the compression test was analyzed using scanning electron microscopy (SEM). (3) Results: statistical analysis (ANOVA and Tukey test) showed that there was a statistically significant difference between G1 and the other groups. Even though there was no statistically significant difference between the restored groups, a better mechanical behavior was registered within the G3. (4) Conclusions: this in vitro study indicated that none of the materials used can lead to a higher or at least similar fracture resistance as the intact teeth. The coronal restoration only with nano-hybrid composites may lead to a higher therapeutic benefit for the fracture-susceptible premolars.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dentistry Journal
Dentistry Journal Dentistry-Dentistry (all)
CiteScore
3.70
自引率
7.70%
发文量
213
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信