Wenxi Zhang, Jing Sun, Xiao Li, Sibo Wang, Weitao Zhang, Yaru Gong, Lei Liu, Zhongmin Su
{"title":"基于镧系元素 MOF 的发光传感器阵列,用于检测和识别水中污染物及生物标记物。","authors":"Wenxi Zhang, Jing Sun, Xiao Li, Sibo Wang, Weitao Zhang, Yaru Gong, Lei Liu, Zhongmin Su","doi":"10.1016/j.talanta.2024.126853","DOIUrl":null,"url":null,"abstract":"<p><p>In today's society, heavy metal ions and antibiotic contaminants have caused great harm to water systems and human health. In this study, six isostructural lanthanide metal-organic frameworks [Ln(H<sub>3</sub>imda)<sub>2</sub>(TPA)(H<sub>2</sub>O)<sub>2</sub>](Tb for CUST-881, Eu for CUST-882, Dy for CUST-883, Er for CUST-884, Nd for CUST-885, Sm for CUST-886) were constructed by selecting terephthalic acid (TPA) and 4,5-Imidazoledicarboxylic acid (H<sub>3</sub>imda) and lanthanide metal ions via solvethermal method. Among them, CUST-881 and CUST-882 can selectively detect Fe<sup>3+</sup>, Cr<sub>2</sub>O<sub>7</sub><sup>2-</sup>, CrO<sub>4</sub><sup>2</sup>, and ceftriaxone sodium (CRO) in water systems and uric acid in urine. CUST-881 shows very low detection limits for these five substances. Furthermore, Principal Component Analysis (PCA) was used to distinguish Fe<sup>3+</sup>, Cr<sub>2</sub>O<sub>7</sub><sup>2-</sup>, CrO<sub>4</sub><sup>2-,</sup> and CRO in water. To our knowledge, this is the first time that they have been able to be simultaneously distinguished. In addition, the possible sensing mechanism was studied through UV-visible spectroscopy, Infrared spectroscopy, and PXRD analysis. Furthermore, the probe also showed satisfactory repeatability and recovery when applied to UA samples that simulated urine. Based on the above results, lanthanide metal-organic frameworks have great potential for practical monitoring of contaminants in water environments.</p>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"281 ","pages":"126853"},"PeriodicalIF":5.6000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Lanthanide MOF-based luminescent sensor array for detection and identification of contaminants in water and biomarkers.\",\"authors\":\"Wenxi Zhang, Jing Sun, Xiao Li, Sibo Wang, Weitao Zhang, Yaru Gong, Lei Liu, Zhongmin Su\",\"doi\":\"10.1016/j.talanta.2024.126853\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In today's society, heavy metal ions and antibiotic contaminants have caused great harm to water systems and human health. In this study, six isostructural lanthanide metal-organic frameworks [Ln(H<sub>3</sub>imda)<sub>2</sub>(TPA)(H<sub>2</sub>O)<sub>2</sub>](Tb for CUST-881, Eu for CUST-882, Dy for CUST-883, Er for CUST-884, Nd for CUST-885, Sm for CUST-886) were constructed by selecting terephthalic acid (TPA) and 4,5-Imidazoledicarboxylic acid (H<sub>3</sub>imda) and lanthanide metal ions via solvethermal method. Among them, CUST-881 and CUST-882 can selectively detect Fe<sup>3+</sup>, Cr<sub>2</sub>O<sub>7</sub><sup>2-</sup>, CrO<sub>4</sub><sup>2</sup>, and ceftriaxone sodium (CRO) in water systems and uric acid in urine. CUST-881 shows very low detection limits for these five substances. Furthermore, Principal Component Analysis (PCA) was used to distinguish Fe<sup>3+</sup>, Cr<sub>2</sub>O<sub>7</sub><sup>2-</sup>, CrO<sub>4</sub><sup>2-,</sup> and CRO in water. To our knowledge, this is the first time that they have been able to be simultaneously distinguished. In addition, the possible sensing mechanism was studied through UV-visible spectroscopy, Infrared spectroscopy, and PXRD analysis. Furthermore, the probe also showed satisfactory repeatability and recovery when applied to UA samples that simulated urine. Based on the above results, lanthanide metal-organic frameworks have great potential for practical monitoring of contaminants in water environments.</p>\",\"PeriodicalId\":435,\"journal\":{\"name\":\"Talanta\",\"volume\":\"281 \",\"pages\":\"126853\"},\"PeriodicalIF\":5.6000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Talanta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1016/j.talanta.2024.126853\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/9/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.talanta.2024.126853","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/20 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Lanthanide MOF-based luminescent sensor array for detection and identification of contaminants in water and biomarkers.
In today's society, heavy metal ions and antibiotic contaminants have caused great harm to water systems and human health. In this study, six isostructural lanthanide metal-organic frameworks [Ln(H3imda)2(TPA)(H2O)2](Tb for CUST-881, Eu for CUST-882, Dy for CUST-883, Er for CUST-884, Nd for CUST-885, Sm for CUST-886) were constructed by selecting terephthalic acid (TPA) and 4,5-Imidazoledicarboxylic acid (H3imda) and lanthanide metal ions via solvethermal method. Among them, CUST-881 and CUST-882 can selectively detect Fe3+, Cr2O72-, CrO42, and ceftriaxone sodium (CRO) in water systems and uric acid in urine. CUST-881 shows very low detection limits for these five substances. Furthermore, Principal Component Analysis (PCA) was used to distinguish Fe3+, Cr2O72-, CrO42-, and CRO in water. To our knowledge, this is the first time that they have been able to be simultaneously distinguished. In addition, the possible sensing mechanism was studied through UV-visible spectroscopy, Infrared spectroscopy, and PXRD analysis. Furthermore, the probe also showed satisfactory repeatability and recovery when applied to UA samples that simulated urine. Based on the above results, lanthanide metal-organic frameworks have great potential for practical monitoring of contaminants in water environments.
期刊介绍:
Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome.
Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.