基台材料、骨水泥厚度和牙冠类型对种植体支持修复体最终颜色的影响。

Hamiyet Kilinc, Fatma Ayse Sanal
{"title":"基台材料、骨水泥厚度和牙冠类型对种植体支持修复体最终颜色的影响。","authors":"Hamiyet Kilinc, Fatma Ayse Sanal","doi":"10.11607/ijp.8564","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the influence of abutment material, cement thickness, and crown type on the esthetics of implant supported restorations.</p><p><strong>Material and methods: </strong>In total, 60 specimens were prepared to represent six abutment groups: Group PA &#61; pink-anodized Ti; Group GA &#61; gold-anodized Ti; Group T &#61; nonanodized Ti; Group H &#61; hybrid (Ti &#43; zirconia); Group P &#61; PEEK (Ti &#43; PEEK); and Group C &#61; composite resin (control). Crown specimens (n &#61; 120) were obtained from Vita Enamic (VE) and Vita Suprinity (VS). Two cement thicknesses (0.1 and 0.2 mm) were used. The color values of crown configura:ons were measured and ΔE00* values were calculated. Statistical analyses included were Shapiro Wilk, three-way ANOVA, and Tukey HSD tests (P ≤ .05).</p><p><strong>Results: </strong>Abutment (P < .001) and crown materials (P &#61; .001) had a significant effect on ΔE00* values, while cement thickness did not. Groups PA and H resulted in significantly lower mean ΔE00* values than other abutments, whereas Group T revealed the highest. Unlike VS, cement thicknesses created a significant difference on the ΔE00* values for VE (P ≤.05).</p><p><strong>Conclusions: </strong>Pink-anodized Ti or hybrid abutments for VE and pink- or goldanodized Ti for VS seem to be better options, in terms of color change. Cement thickness of 0.1 mm resulted in higher ΔE00* value than 0.2 mm for VE (P ≤ .05).</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"37 5","pages":"211-222"},"PeriodicalIF":0.0000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"INFLUENCE OF ABUTMENT MATERIAL, CEMENT THICKNESS, AND CROWN TYPE ON THE FINAL COLOR OF IMPLANT-SUPPORTED RESTORATIONS.\",\"authors\":\"Hamiyet Kilinc, Fatma Ayse Sanal\",\"doi\":\"10.11607/ijp.8564\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the influence of abutment material, cement thickness, and crown type on the esthetics of implant supported restorations.</p><p><strong>Material and methods: </strong>In total, 60 specimens were prepared to represent six abutment groups: Group PA &#61; pink-anodized Ti; Group GA &#61; gold-anodized Ti; Group T &#61; nonanodized Ti; Group H &#61; hybrid (Ti &#43; zirconia); Group P &#61; PEEK (Ti &#43; PEEK); and Group C &#61; composite resin (control). Crown specimens (n &#61; 120) were obtained from Vita Enamic (VE) and Vita Suprinity (VS). Two cement thicknesses (0.1 and 0.2 mm) were used. The color values of crown configura:ons were measured and ΔE00* values were calculated. Statistical analyses included were Shapiro Wilk, three-way ANOVA, and Tukey HSD tests (P ≤ .05).</p><p><strong>Results: </strong>Abutment (P < .001) and crown materials (P &#61; .001) had a significant effect on ΔE00* values, while cement thickness did not. Groups PA and H resulted in significantly lower mean ΔE00* values than other abutments, whereas Group T revealed the highest. Unlike VS, cement thicknesses created a significant difference on the ΔE00* values for VE (P ≤.05).</p><p><strong>Conclusions: </strong>Pink-anodized Ti or hybrid abutments for VE and pink- or goldanodized Ti for VS seem to be better options, in terms of color change. Cement thickness of 0.1 mm resulted in higher ΔE00* value than 0.2 mm for VE (P ≤ .05).</p>\",\"PeriodicalId\":94232,\"journal\":{\"name\":\"The International journal of prosthodontics\",\"volume\":\"37 5\",\"pages\":\"211-222\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The International journal of prosthodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.8564\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.8564","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估基台材料、骨水泥厚度和牙冠类型对种植体支持修复体美观的影响:共制备了 60 个样本,代表六组基台:PA 组;粉红阳极氧化 Ti;GA 组;金阳极氧化 Ti;T 组;非阳极氧化 Ti;H 组;混合(Ti +;氧化锆);P 组;PEEK(Ti +;PEEK);C 组;复合树脂(对照组)。牙冠样本(n =;120)来自 Vita Enamic (VE) 和 Vita Suprinity (VS)。使用了两种粘接剂厚度(0.1 毫米和 0.2 毫米)。测量牙冠配置的颜色值并计算 ΔE00* 值。统计分析包括 Shapiro Wilk、三方方差分析和 Tukey HSD 检验(P ≤ .05):结果:基台(P < .001)和牙冠材料(P = .001)对 ΔE00* 值有显著影响,而骨水泥厚度没有影响。PA 组和 H 组的平均 ΔE00* 值明显低于其他基台,而 T 组则最高。与 VS 不同,水门汀厚度对 VE 的 ΔE00* 值产生了显著差异(P ≤.05):结论:就颜色变化而言,粉红色阳极氧化钛或混合基台用于 VE,粉红色或金色阳极氧化钛用于 VS 似乎是更好的选择。对于 VE,0.1 毫米的水泥厚度比 0.2 毫米的水泥厚度产生的 ΔE00* 值更高(P ≤ .05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
INFLUENCE OF ABUTMENT MATERIAL, CEMENT THICKNESS, AND CROWN TYPE ON THE FINAL COLOR OF IMPLANT-SUPPORTED RESTORATIONS.

Purpose: To evaluate the influence of abutment material, cement thickness, and crown type on the esthetics of implant supported restorations.

Material and methods: In total, 60 specimens were prepared to represent six abutment groups: Group PA = pink-anodized Ti; Group GA = gold-anodized Ti; Group T = nonanodized Ti; Group H = hybrid (Ti + zirconia); Group P = PEEK (Ti + PEEK); and Group C = composite resin (control). Crown specimens (n = 120) were obtained from Vita Enamic (VE) and Vita Suprinity (VS). Two cement thicknesses (0.1 and 0.2 mm) were used. The color values of crown configura:ons were measured and ΔE00* values were calculated. Statistical analyses included were Shapiro Wilk, three-way ANOVA, and Tukey HSD tests (P ≤ .05).

Results: Abutment (P < .001) and crown materials (P = .001) had a significant effect on ΔE00* values, while cement thickness did not. Groups PA and H resulted in significantly lower mean ΔE00* values than other abutments, whereas Group T revealed the highest. Unlike VS, cement thicknesses created a significant difference on the ΔE00* values for VE (P ≤.05).

Conclusions: Pink-anodized Ti or hybrid abutments for VE and pink- or goldanodized Ti for VS seem to be better options, in terms of color change. Cement thickness of 0.1 mm resulted in higher ΔE00* value than 0.2 mm for VE (P ≤ .05).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信