对支持固定义齿的 2.8 毫米直径种植体长达 11 年的临床和放射学效果的回顾性研究。

Lianyi Xu, Yue Ma, Xijin Du, Ying Qing, Yingguang Cao, Xiaojuan Sun, Reinhilde Jacobs, Ke Song
{"title":"对支持固定义齿的 2.8 毫米直径种植体长达 11 年的临床和放射学效果的回顾性研究。","authors":"Lianyi Xu, Yue Ma, Xijin Du, Ying Qing, Yingguang Cao, Xiaojuan Sun, Reinhilde Jacobs, Ke Song","doi":"10.1111/cid.13395","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to report the clinical and radiographic results of 2.8 mm two-piece narrow diameter implant (NDI) supporting fixed restorations.</p><p><strong>Materials and methods: </strong>Clinical and radiographic data of 54 NDIs in 32 patients were retrospectively assessed after 2 to 11 (mean 8.17) years of follow-up. Clinical and radiographic measurements were taken. Survival rate, implant and prosthesis failure, pink aesthetic scores (PES), white aesthetic scores (WES), bleeding on probing (BOP), probing depth (PD), marginal bone loss (MBL), and mechanical and biological complications were evaluated.</p><p><strong>Results: </strong>An implant failed during the follow-up period, resulting in a cumulative survival rate of 98.15% at the implant level and 96.88% in the patient. The total mean values of PES and WES for 2.8 mm NDIs were 7.09 ± 1.15 (range: 3.33-9.00) and 7.42 ± 1.03 (range: 3.67-9.33). The prevalence of sites with positive BOP was 38.14 ± 29.77%. The mean PD value was 2.46 ± 0.62 mm. The average MBL was 1.15 ± 0.74 mm (range: 0.25-4.03 mm). No implant or abutment fracture was detected. A veneer chipping was present in one patient, and a loose crown appeared in another patient. Two implants (3.7%) and two patients (6.3%) were diagnosed with peri-implantitis.</p><p><strong>Conclusion: </strong>Within the limitation of the study, the results indicate that the use of two-piece 2.8 mm NDI for the fixed prosthetic rehabilitation of edentulous regions with reduced interdental and/or buccal-lingual width is viable.</p>","PeriodicalId":93944,"journal":{"name":"Clinical implant dentistry and related research","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Retrospective study on the clinical and radiographic outcomes of 2.8 mm diameter implants supporting fixed prostheses up to 11 years.\",\"authors\":\"Lianyi Xu, Yue Ma, Xijin Du, Ying Qing, Yingguang Cao, Xiaojuan Sun, Reinhilde Jacobs, Ke Song\",\"doi\":\"10.1111/cid.13395\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This study aimed to report the clinical and radiographic results of 2.8 mm two-piece narrow diameter implant (NDI) supporting fixed restorations.</p><p><strong>Materials and methods: </strong>Clinical and radiographic data of 54 NDIs in 32 patients were retrospectively assessed after 2 to 11 (mean 8.17) years of follow-up. Clinical and radiographic measurements were taken. Survival rate, implant and prosthesis failure, pink aesthetic scores (PES), white aesthetic scores (WES), bleeding on probing (BOP), probing depth (PD), marginal bone loss (MBL), and mechanical and biological complications were evaluated.</p><p><strong>Results: </strong>An implant failed during the follow-up period, resulting in a cumulative survival rate of 98.15% at the implant level and 96.88% in the patient. The total mean values of PES and WES for 2.8 mm NDIs were 7.09 ± 1.15 (range: 3.33-9.00) and 7.42 ± 1.03 (range: 3.67-9.33). The prevalence of sites with positive BOP was 38.14 ± 29.77%. The mean PD value was 2.46 ± 0.62 mm. The average MBL was 1.15 ± 0.74 mm (range: 0.25-4.03 mm). No implant or abutment fracture was detected. A veneer chipping was present in one patient, and a loose crown appeared in another patient. Two implants (3.7%) and two patients (6.3%) were diagnosed with peri-implantitis.</p><p><strong>Conclusion: </strong>Within the limitation of the study, the results indicate that the use of two-piece 2.8 mm NDI for the fixed prosthetic rehabilitation of edentulous regions with reduced interdental and/or buccal-lingual width is viable.</p>\",\"PeriodicalId\":93944,\"journal\":{\"name\":\"Clinical implant dentistry and related research\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical implant dentistry and related research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1111/cid.13395\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical implant dentistry and related research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/cid.13395","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在报告 2.8 毫米两件式窄直径种植体(NDI)支持固定修复体的临床和放射学结果:对 32 名患者的 54 个 NDI 的临床和放射学数据进行了回顾性评估,随访时间为 2 至 11 年(平均 8.17 年)。进行了临床和放射学测量。对存活率、种植体和修复体失败率、粉色美学评分(PES)、白色美学评分(WES)、探诊出血(BOP)、探诊深度(PD)、边缘骨质流失(MBL)以及机械和生物并发症进行了评估:随访期间有一颗种植体失败,种植体的累积存活率为 98.15%,患者的累积存活率为 96.88%。2.8 mm NDI 的 PES 和 WES 总平均值分别为 7.09 ± 1.15(范围:3.33-9.00)和 7.42 ± 1.03(范围:3.67-9.33)。BOP阳性部位的发生率为 38.14 ± 29.77%。平均 PD 值为 2.46 ± 0.62 毫米。平均 MBL 为 1.15 ± 0.74 毫米(范围:0.25-4.03 毫米)。未发现种植体或基台断裂。一名患者的贴面出现崩裂,另一名患者的牙冠出现松动。两名种植体(3.7%)和两名患者(6.3%)被诊断为种植体周围炎:研究结果表明,在牙间和/或颊舌宽度减小的无牙颌区域,使用两片式 2.8 毫米 NDI 进行固定修复是可行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Retrospective study on the clinical and radiographic outcomes of 2.8 mm diameter implants supporting fixed prostheses up to 11 years.

Objectives: This study aimed to report the clinical and radiographic results of 2.8 mm two-piece narrow diameter implant (NDI) supporting fixed restorations.

Materials and methods: Clinical and radiographic data of 54 NDIs in 32 patients were retrospectively assessed after 2 to 11 (mean 8.17) years of follow-up. Clinical and radiographic measurements were taken. Survival rate, implant and prosthesis failure, pink aesthetic scores (PES), white aesthetic scores (WES), bleeding on probing (BOP), probing depth (PD), marginal bone loss (MBL), and mechanical and biological complications were evaluated.

Results: An implant failed during the follow-up period, resulting in a cumulative survival rate of 98.15% at the implant level and 96.88% in the patient. The total mean values of PES and WES for 2.8 mm NDIs were 7.09 ± 1.15 (range: 3.33-9.00) and 7.42 ± 1.03 (range: 3.67-9.33). The prevalence of sites with positive BOP was 38.14 ± 29.77%. The mean PD value was 2.46 ± 0.62 mm. The average MBL was 1.15 ± 0.74 mm (range: 0.25-4.03 mm). No implant or abutment fracture was detected. A veneer chipping was present in one patient, and a loose crown appeared in another patient. Two implants (3.7%) and two patients (6.3%) were diagnosed with peri-implantitis.

Conclusion: Within the limitation of the study, the results indicate that the use of two-piece 2.8 mm NDI for the fixed prosthetic rehabilitation of edentulous regions with reduced interdental and/or buccal-lingual width is viable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信