Mario R Romano, Mariantonia Ferrara, Alessandro Feo, Anna Merico, Martina Angi
{"title":"优化葡萄膜黑色素瘤内切术的手术性能和安全性。","authors":"Mario R Romano, Mariantonia Ferrara, Alessandro Feo, Anna Merico, Martina Angi","doi":"10.1097/IAE.0000000000004273","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To present a standardized surgical technique for endoresection of uveal melanoma (UM) minimizing the risk of serious adverse events, including fatal gas embolism.</p><p><strong>Methods: </strong>Ten UM patients underwent endoresection following proton beam radiotherapy for radiotherapy-related vascular complications. Vortex veins located in correspondence of the tumor base had been cauterized at the time of tantalum markers placement. Endoresection was performed following complete 25G vitrectomy, endolaser and endodiathermy. The tumor was removed using a subretinal or transretinal approach depending on retinal infiltration. If needed, perfluorodecalin (PFD) was injected to stabilise the retina. Fluid-silicone oil (SO) or PFD-SO exchange was performed, avoiding air.</p><p><strong>Results: </strong>Endoresection was successfully performed in all eyes with no intraoperative complications. Mean follow-up (FU) was 10.8 ± 3.2 months. One patient was enucleated due to neovascular glaucoma. At the last FU, the remaining patients had the eye preserved and no signs of local recurrence or neovascular glaucoma.</p><p><strong>Conclusion: </strong>Our standardized surgical technique for UM endoresection appeared to be safe, minimizing the risk of serious intraoperative and postoperative adverse events.</p>","PeriodicalId":54486,"journal":{"name":"Retina-The Journal of Retinal and Vitreous Diseases","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimizing surgical performance and safety in endoresection of uveal melanoma.\",\"authors\":\"Mario R Romano, Mariantonia Ferrara, Alessandro Feo, Anna Merico, Martina Angi\",\"doi\":\"10.1097/IAE.0000000000004273\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To present a standardized surgical technique for endoresection of uveal melanoma (UM) minimizing the risk of serious adverse events, including fatal gas embolism.</p><p><strong>Methods: </strong>Ten UM patients underwent endoresection following proton beam radiotherapy for radiotherapy-related vascular complications. Vortex veins located in correspondence of the tumor base had been cauterized at the time of tantalum markers placement. Endoresection was performed following complete 25G vitrectomy, endolaser and endodiathermy. The tumor was removed using a subretinal or transretinal approach depending on retinal infiltration. If needed, perfluorodecalin (PFD) was injected to stabilise the retina. Fluid-silicone oil (SO) or PFD-SO exchange was performed, avoiding air.</p><p><strong>Results: </strong>Endoresection was successfully performed in all eyes with no intraoperative complications. Mean follow-up (FU) was 10.8 ± 3.2 months. One patient was enucleated due to neovascular glaucoma. At the last FU, the remaining patients had the eye preserved and no signs of local recurrence or neovascular glaucoma.</p><p><strong>Conclusion: </strong>Our standardized surgical technique for UM endoresection appeared to be safe, minimizing the risk of serious intraoperative and postoperative adverse events.</p>\",\"PeriodicalId\":54486,\"journal\":{\"name\":\"Retina-The Journal of Retinal and Vitreous Diseases\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-09-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Retina-The Journal of Retinal and Vitreous Diseases\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/IAE.0000000000004273\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Retina-The Journal of Retinal and Vitreous Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IAE.0000000000004273","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Optimizing surgical performance and safety in endoresection of uveal melanoma.
Purpose: To present a standardized surgical technique for endoresection of uveal melanoma (UM) minimizing the risk of serious adverse events, including fatal gas embolism.
Methods: Ten UM patients underwent endoresection following proton beam radiotherapy for radiotherapy-related vascular complications. Vortex veins located in correspondence of the tumor base had been cauterized at the time of tantalum markers placement. Endoresection was performed following complete 25G vitrectomy, endolaser and endodiathermy. The tumor was removed using a subretinal or transretinal approach depending on retinal infiltration. If needed, perfluorodecalin (PFD) was injected to stabilise the retina. Fluid-silicone oil (SO) or PFD-SO exchange was performed, avoiding air.
Results: Endoresection was successfully performed in all eyes with no intraoperative complications. Mean follow-up (FU) was 10.8 ± 3.2 months. One patient was enucleated due to neovascular glaucoma. At the last FU, the remaining patients had the eye preserved and no signs of local recurrence or neovascular glaucoma.
Conclusion: Our standardized surgical technique for UM endoresection appeared to be safe, minimizing the risk of serious intraoperative and postoperative adverse events.
期刊介绍:
RETINA® focuses exclusively on the growing specialty of vitreoretinal disorders. The Journal provides current information on diagnostic and therapeutic techniques. Its highly specialized and informative, peer-reviewed articles are easily applicable to clinical practice.
In addition to regular reports from clinical and basic science investigators, RETINA® publishes special features including periodic review articles on pertinent topics, special articles dealing with surgical and other therapeutic techniques, and abstract cards. Issues are abundantly illustrated in vivid full color.
Published 12 times per year, RETINA® is truly a “must have” publication for anyone connected to this field.